Streszczenie treści zawartej na stronie nr. 1 
                    
                        installation & operating Manual
The TL300 Top Loading Wood Stove    
EPA Certified by 
r5
OMNI-Test Laboratories
SaFeTY noTice
PLeaSe read ThiS enTire ManuaL beFore You inST aLL and uSe Your neW rooM hea Ter.  FaiLure 
To FoLLoW inSTrucTionS Ma Y reSuLT in ProPerTY daMage, bodiLY injur Y, or even dea Th.
For uSe in The u.S. and canada.  SuiT abLe For inST aLLa Tion in a MobiLe hoMe(uS onLY).
iF ThiS Wood-burning ST ove iS no T Pro Per LY inSTa LLed , a hou Se Fire MaY re SuLT.  For Your Sa FeTY,
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        2 Harman TL300                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        index Introduction   4 Specifications   5 Installation   8 Venting    10 Operation/Building a Fire 16 Maintenance   19 Options    21   Service Parts   22 Warranty    26 Please read this entire manual before you install and use your new heating  appliance.  Failure to follow instructions may result in property damage,  bodily injury, or even death. Hearth & Home Technologies, Inc. 352 Mountain House Road Halifax, PA 17032 ~ U.S.A.      Harman TL300 3                                               
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        introduction Thank you for purchasing the Harman TL300 Wood Stove. We are confident that you will enjoy the warmth and convenience  of your Harman Stove for decades to come.  With the TL300 you will notice even heat throughout your home and long burn times. This is possible because of  Harman’s special FireDome Non-Catalytic Combustion System, designed into the TL300 to promote clean burning and even  heat output. This equates to unvarying heat over a longer period of time without the temperatur
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        734 mm 675 mm Specifications Weight 525 Lbs Flue Size 6 inch Log Length Recommended 18 in. / 20 in. Max Heating Capacity 1,500 - 3000 sq. ft. Average Emissions 1.1 Grams Per Hr. Emissons on Low 0.8 Grams Per Hr. Outside Air Size 3 or 4 inch SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED,  A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE  INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR  FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION  INSPECTION REQUIREMENTS IN YOUR AREA. The Ha
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        Specifications Top Load Door Top Load Opening Front Load Door Grate Top Load Door  Handle Andirons Air Control Ash Door Front Load Door Latch Ash Door Latch 6 Harman TL300                                                                                                                                                                                                                                                                                                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Specifications The Stove General Considerations Doors Draft Your stove has a large glass-paneled door for loading and  Before you install and/or operate your TL300 wood stove,  fire viewing, a separate smaller door for removing ashes, and  please read the entire contents of this manual. Pay particular  a top loading door.   attention to the explanation of draft and its effect on stove Front Door performance, in the installation section. By following the Before opening, always check for wood, emb
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        installation 44" (1100 mm) Clearances Clearance is the empty space required between the stove  8" (200 mm) or chimney connector and the nearest combustible surface or  object, such as walls, ceilings, floors, or furniture.  Clearance  distances may only be reduced by using methods approved  by either the CAN/CSA B365 standard (Canada) or NFPA  211 (U.S.)  Contact your building authority for information  8" 8" if you are interested in reducing clearance distances below  (200 mm) (200 mm) those pr
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        installation/clearances Single Wall  Pipe - Parallel Installation 15"* 375 mm 31" (775 mm) 31" 2' (50 mm) 23" (775 mm) (575 mm) 20" (500 mm) 17" 425 mm Top vent vented out back wall  Top Vent to vented out side wall  Top vent ceiling and sidewall Damper Open Damper Closed o  o  with 90 elbow. with 90 elbow clearances  24" 18" 23" 17" (600 mm) (450 mm) (575 mm) 425 mm) 31" (775 mm) 20" (500 mm) Single Wall  Pipe -  Top Vent  - Parallel Installation Double Wall  Pipe - Parallel Installation 11"*(2
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        venting Chimney Connectors and Chimneys No part of the chimney connector may pass through an attic  or roof space, closet or other concealed space, or through a  Draft floor or ceiling. Whenever possible, avoid passing the connec- Draft is widely misunderstood.  It is important that you,  tor through a combustible wall; if you must, use an approved  the stove operator, realize that draft is a variable effect, not  wall pass-through, described later in this section.  a given quantity. Stoves and 
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        venting Non-combustible cover, one  Closest  side only. If two covers are  Combustible Minimum 2" (50mm) Hole with a minimum used, each must be mounted  Material Clearance to Brick on non-combustible spacers  clearance of  18" (450 mm)  at least 7/8" (21mm) away  between connector and wall. Minimum 12"  from the wall. Liner (300mm) to Brick Fire Clay Thimble Chimney  Connector    1" (25mm) Masonry Chimney Built to     Clearance NFPA 211 Specifications. Minimum 12" (300mm)  to Combustibles AN APP
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        venting Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have  it thoroughly inspected and cleaned. Any faults which make  the chimney unsafe and unusable must be repaired prior to  use. These can include improper height, structural defects,  blockages, inadequate clearance to combustibles, unsealed  openings into other rooms of the house, signs of creosote or  smoke leakage, a loose or absent clean-out door, or absence  of a liner. Do not connect to any air distrib
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        venting Standard Ceiling Installation with  Cathedral Ceiling Installation with  Factory Built Chimney Factory Built Chimney      Harman TL300 13                                                                                                                                                                                                                                                                                                                                                                   
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        venting Chimney Breach Fireplace Conversion with Non-Combustible Wall Minimum Clearance to Unprotected Ceiling  18" Chimney Connector  Sealed at Thimble Flue Liner with Re- quired Air Space Minimum of three Sheet  Airtight Metal Screws per Joint of  insulated Chimney Connector Clean-out Mantel and Trim  Protection Damper Closed  and Sealed with  Floor Protection* Non-Combus- tible Material. Combustible Floor * Floor Protection in Accordance  with Solid Fuel Appliance Listing 14 Harman TL300     
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        venting Chimney Breach Fireplace Conversion with Combustible Wall Minimum Clearance from  Chimney Connector to Un- protected Ceiling 15"** Flue Liner with Required Air Space Listed or Approved Thimble Assembly Combustible  1" Clearance for Exterior  Wall Chimney or  2" Clearance  for Interior Chimney and 2"  Clearance for NFPA 211-Type  Sheetrock Airtight  Approved Thimbles insulated  Clean-out Mantel &  Trim  Protection Damper Closed  and Sealed with  Noncombustible  Material. Floor Protection*
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        operation Two important controls - the top load door handle and  The Combustion Process the air control lever regulate the operation and output  Combustion in the Harman TL300 is precisely con- of the stove. trolled and is divided into two parts. Top loading door handle/damper interlock.The top  During combustion, primary air enters at the bot- loading door handle is linked to the bypass damper and  tom front of the stove and travels up channels at either  serves two purposes. Move the handle fo
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        building a Fire Building and Maintaining the Fire Do not use chemicals or fluids  to start the fire. Never use gasoline, gasoline-type lantern fuel,  kerosene, charcoal lighter fluid, or similar liquids  to start or “freshen up” a fire in this heater.  Keep  all such liquids well away from the heater while  it is in use. Begin with the bypass damper open, and the air  control lever at the maximum setting, all the way to the  right. Be sure the ash pan door is closed and latched.   Start with a b
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        building a Fire Building and Maintaining the Fire Cont. Always remember to open the bypass damper when Avoid overfiring your stove.  you are loading, this allows the exhaust gases to pass Overfiring is a potentially hazardous situation which  can lead to overheating of combustible materials, dam- directly into the flue outlet and reduces the chance of  age to the stove, and in extreme cases, cause a fire.  smoke spillage into the room.    Overfiring is caused by:  Reloading:  Once you have prepa
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        Maintenance Glass - Replacement Like all fine equipment, your TL300 requires some  If  the stove’s glass is cracked or broken, you must  routine maintenance and inspection. Follow the guide- replace it before operating your stove.  Remove pieces  lines in this section to assure safe, efficient operation. carefully. Replace glass only with Harman replacement  glass; do not use substitutes. To replace the glass panel, you will need to  The Stove remove the door. To do this, open the door,  lift it
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        Maintenance Gaskets The Chimney System Gaskets are used at strategic positions when building  Creosote  the Harman TL300 for controlling the path that incom- When wood is burned slowly, it produces tar and other  ing and outgoing air and gases take through the stove.  organic vapors, as well as soot, which combine with  You must check these gaskets from time to time and  expelled moisture to form creosote. The creosote vapors  replace them when necessary. The gaskets are made  condense in the re