USER’S INFORMATION MANUAL
MODEL 340MAV, 350MAV, 352MAV, 
355MAV CONDENSING GAS 
FURNACE
USER: Please read all instructions in
NOTE  TO INSTALLER:
the manual and retain all manuals for
This manual must be left with the equipment user.
future reference.
! WARNING: 
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
—  Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                                                                                          Shutting Down Your Furnace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 TABLE OF CONTENTS PERFORMING ROUTINE MAINTENANCE. . . . . . . . . . . . . . . . . . . . 6 WELCOME TO A NEW GENERATION OF COMFORT. . . . . . . . .2 Filtering Out Trouble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 GENERAL FURNACE SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 COMBUSTION AREA A
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                                FURNACE COMPONENTS 17 1 Combustion-air intake connection to ensure  2 contaminant-free air (right or left side). 3 1 2 Burner sight glass for viewing burner flame. 12 4 3 Burner assembly (inside). Operates with energy- 18 saving inshot burners and hot surface igniter for safe,  dependable heating. 5 5 4 Redundant gas valve. Safe and efficient. Features 1 gas  11 14 control with 2 internal shutoff valves. Valve appearance  varies with furnace model. 16 15 6 5 Vent outlet. Uses PVC pipe to
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                                                       SAFETY BEFORE STARTING  CONSIDERATIONS YOUR FURNACE  Examine the furnace installation to  Recognize safety information. This is  determine that: the safety-alert symbol ! . When you  see this symbol on the furnace and in  1. All flue gas carrying areas external  instructions or manuals, be alert to the  to the furnace (i.e. chimney, vent  potential for personal injury. connector) are clear and free of  obstructions. Understand the signal words DANGER,  WARNING, CAUT
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        ON OFF ON OFF E S O L C                     the floor. If you smell gas, STOP!   Follow “B” in the safety information  above on this furnace label. If you  don’t smell gas, go to the next step. or OR • If a suspected malfunction occurs  with your gas control system, such as  the burners not lighting when they  should, refer to the shutdown proce- For 340MAV and 350MAV dures on inside of main furnace door,  or in the “Shutting Down Your Fur- 13 nace” section and call your dealer as  soon as possib
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        ON OFF N E P O                     necessary adjustments to operate When room temperature drops  20 the blower at either the low- or below the temperature selected  2. Close the external manual gas  high-heat speed. on the thermostat, the furnace  valve. (See Fig. 9.) will be switched on automatically.    3. Turn off electrical supply to the  When room temperature reaches  furnace. (See Fig. 20.) the temperature selected on the  4. Remove main furnace door.  thermostat, the furnace will be  (See
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                          of airflow occurs, the furnace may cycle  Installing and servicing of heating  on its safety controls. If this condition is  equipment can be hazardous due to  left unattended, the furnace will eventu- gas and electrical components.  ally lock out. It is recommended that the  Only trained and qualified personnel  furnace air filter be checked every 3 or 4  should install, repair, or service heat- weeks and cleaned if necessary.  ing equipment. Untrained personnel  If installed with factory-specifi
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        direction arrow pointing towards  blower. b. Electronic air cleaner (EAC) –  Refer to EAC owner’s Manual  for maintenance information. 34 31 5. If washable filter, wash filter (if  dirty) in sink, bathtub, or outside  with a garden hose. Always use  27 cold tap water. A mild liquid deter- gent may be used if necessary.  Spray water through filter in the  opposite direction of airflow.  Allow filter to dry. 6. Reinstall clean air filter. 7. Reinstall filter retainer (for blower  compartment locations on
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        When dirt, soot, scale, or rust is  FURNACE AIR FILTER  allowed to build up, your furnace can  TABLE suffer a loss of efficiency and perform  AIR FILTER LOCATED IN BLOWER COMPARTMENT improperly. Accumulations on the  FILTER SIZE FURNACE  main burners can result in firing out of  (IN.) CASING  normal sequence. This delayed igni- WIDTH *Side Bottom FILTER  (IN.) Return† Return TYPE tion creates an alarmingly loud sound. 17-1/2 (1) 16 x (1) 16 x Cleanable 25 x 1* 25 x 1* ! CAUTION 21 (1) 16 x (1) 20 
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        transfer process. Therefore, once it • Inspect and clean the blower motor  has been operated, it cannot be turned and wheel. off and left off for an extended period  NOTE: The inducer and blower motors  of time when temperatures will reach  are pre-lubricated and require no addi- 32°F or lower unless winterized. Fol- tional lubrication. These motors can be  low these procedures to winterize your  identified by the absence of oil ports on  furnace: each end of the motor. 1. Obtain propylene glycol
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        Ensure they are open and unobstructed. NOTE: Turn off electrical supply vent termination outside the structure. before continuing with checklist. If problem still exists, call your dealer If your furnace still fails to operate, call  for service. your service representative. • Is control switch on gas valve in ON  position? (Follow start-up procedures For your convenience, record the fur- IF FURNACE FAILS TO OPERATE: if you must reset switch to ON posi- nace product and serial numbers on  Follow
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        INSTALLATION DATA AIR CONDITIONER OR HEAT PUMP Date Installed OUTDOOR UNIT: Dealer Name Product No. Address Model No. City Serial No. State Zip INDOOR COIL: Telephone Product No. FURNACE Model No. Product No. Serial No. Model No. Serial No. Cancels: OM05-39 OM05-42 © 2003 Bryant  Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 12 Printed in U.S.A.        Catalog No. 5334-017 10-03