                        Performance Pro Series  
Gas Fryers Models 35 & 45
Installation and Operation Manual 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Frymaster, a member of the Commercial Food Equipment Service Association, recommends 
using CFESA Certified Technicians. 
 
JUNE 2005
24-Hour Service Hotline 1-800-551-8633 
 
*8196042*
 
 
                                                                                                                                                                                                    
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        NOTICE  IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS  EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED  DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS,  AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS  WARRANTY WILL BE VOID.  FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE  LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH  ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN 
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                         DANGER   No structural material on the fryer should be altered or removed to accommodate placement of  the fryer under a hood.  Questions?  Call the Frymaster/Dean Service Hotline at 1-800-551-8633.     DANGER  Adequate means must be provided to limit the movement of this appliance without depending  upon the gas line connection.  Single fryers equipped with legs must be stabilized by installing  anchor straps.  All fryers equipped with casters must be stabilized by installing restraining  chai
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        PERFORMANCE PRO SERIES GAS FRYERS MODELS 35 & 45  CHAPTER 1:  GENERAL INFORMATION    1.1 Applicability and Validity    The Pro Series Gas Fryer has been approved by the European Union for sale and installation  in all EU countries.    This manual is applicable to and valid for all Performance Pro Series Atmospheric Gas Fryers  sold in English-speaking countries, including those in the European Union.  Where conflicts  exist between instructions and information in this manual and local or nationa
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        1.3 Safety Information    Before attempting to operate your unit, read the instructions in this manual thoroughly.  Throughout  this manual, you will find notations enclosed in double-bordered boxes similar to the ones that  follow.     CAUTION  CAUTION boxes contain information about actions or conditions that may cause or result  in a malfunction of your system.     WARNING  WARNING boxes contain information about actions or conditions that may cause or result  in damage to your system, and wh
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        1.5 Equipment Description    All Performance Pro Series fryers are of an open-frypot design with no tubes and have a hand-sized  opening into the deep cold zone, which makes cleaning the frypot quick and easy.      Frypots are constructed of welded, heavy-gauge cold-rolled steel or stainless steel.  Heating is  supplied by a burner assembly having multiple gas jets that are focused on ceramic targets located  around the lower side of the frypot.  The burner assembly can be configured for natural
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        35 Model Family  Built-In Controls  Model Filtration (Note:  Millivolt controls require no external power.)  PMJ*35† No Millivolt.  Thermostat knob inside door.  PMJ*35G† No Millivolt.  Thermostat knob on control panel.  No Millivolt.  Thermostat knob on control panel with push-button basket lift control.  PMJ*35GBL†  Electric.  Thermostat knob on control panel with ON/OFF switch or Solid State  PMJ*35E No  Controller or Digital Controller.  No Electric.  CM III Computer.  PMJ*35EC  Electric.  T
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                          45 Model Family (continued from previous page)  Built-In Controls  Model  Filtration (Note:  Millivolt controls require no external power.)  PMJ*45EC No Electric.  CM III Computer.  Electric.  Thermostat knob on control panel with push-button basket lift control  PMJ*45EBL No  and ON/OFF switch or Basket Lift Timer.   PMJ*45EBLC No Electric.  CM III Computer.   Electric.  Thermostat knob on control panel with push-button basket lift control  PMJ*45EBLM No  plus ON/OFF and melt cycle switches. 
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        precautions involved, and have complied with all requirements of applicable national and local  codes.    QUALIFIED SERVICE PERSONNEL    Qualified service personnel are those who are familiar with Frymaster equipment and who have been  authorized by Frymaster, L.L.C. to perform service on the equipment.  All authorized service  personnel are required to be equipped with a complete set of service and parts manuals, and to stock  a minimum amount of parts for Frymaster equipment.  A list of Frymas
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        PERFORMANCE PRO SERIES GAS FRYERS MODELS 35 & 45  CHAPTER 2:  INSTALLATION INSTRUCTIONS      2.1 General Installation Requirements    Qualified, licensed, and/or authorized installation or service personnel, as defined in Section  1.7 of this manual, should perform all installation and service on Frymaster equipment.      Conversion of this appliance from one type of gas to another should only be performed by  qualified, licensed, and/or authorized installation or service personnel as defined in
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        CLEARANCE AND VENTILATION     DANGER  No structural material on the fryer should be altered or removed to accommodate  placement of the fryer under a hood.  Questions?  Call the Frymaster/Dean Service  Hotline at 1-800-551-8633.      DANGER  This appliance must be installed with sufficient ventilation to prevent the occurrence  of unacceptable concentrations of substances harmful to the health of personnel in  the room in which it is installed.    The fryer(s) must be installed with a 6" (150 mm
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        2.3 Pre-Connection Preparations     DANGER  Do not connect this appliance to the gas supply before completing each step in this  section.    After the fryer has been positioned under the fry station exhaust hood, ensure the following has been  accomplished:     1. Adequate means must be provided to limit the movement of fryers without depending upon the  gas line connections.  If a flexible gas hose is used, a restraining cable must be connected at all  times when the fryer is in use.  The restr
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in  accordance with the accompanying tables:    Table 1: CE Standard for Incoming Gas Pressures Model Model 35 Model 45 Gas Type G20 G25 G31 G20 G25 G31 Pressure  20 20-25 37-50 20 20-25 37-50 1 (mbar) Orifice 1,70 1,70 1,05 1,40 0,86 1,40 Size Number of  9 9 9 181818 Orifices Manifold  9 13,5 22,5 7,5 10 20,6 Pressure Air Flow 2,50 3,06 1,51 3,10 3,58 1,80 3 (m /H) 1 (mbar) = 10,2 mm CE   Table 2: Non-CE Stand
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        Table 3: CE Approved Gas Categories Pressure Country Category Gas (mbar) I2E+(S) G20/G25 20/25 BE I3P G31 37 I2 ELL G20/G25 20 DE 13P G31 50 I2 H G20 20 DK-GR-IT G20/G25 20/25 II2Esi3P FR G31 37 ET 50 LU I2E G20/G25 20/25 G20 20 II2H3P ES G31 37 ET 50 G25 25 II2L3P NL G31 50 G20 20 II2H3P IE-PT-GB G31 37     The size of the gas line used for installation is very important.  If the line is too small, the gas  pressure at the burner manifold will be low.  This may cause slow recovery and delayed i
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        2. Open the gas-supply valve to the fryer and check all piping, fittings, and gas connections for  leaks.  A soap and water solution should be used for this purpose.     DANGER  All connections must be sealed with a joint compound suitable for the gas being  used and all connections must be tested with a solution of soapy water before  lighting any pilots.    Never use matches, candles, or any other ignition source to check for leaks.  If gas  odors are detected, shut off the gas supply to the a
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        5.  Check the thermostat calibration or temperature programmed into the computer.    • For units equipped with thermostat controls, refer to the Thermostat Calibration instructions  in Chapter 5.    • For units equipped with other types of controllers, refer to the appropriate section of the  Frymaster Fryer Controllers User’s Manual, provided with your equipment for instructions  on programming and operating your controller.    2.5 Converting to Another Gas Type    Your fryer is configured at t
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        PERFORMANCE PRO SERIES GAS FRYERS MODELS 35 & 45  CHAPTER 3:  OPERATING INSTRUCTIONS      3.1 Start-Up Procedure     DANGER  Never operate this appliance with an empty frypot.  The frypot must be filled with  water or cooking oil/shortening before lighting the burners.  Failure to do so will  damage the frypot and may cause a fire.     WARNING  The on-site supervisor is responsible for ensuring that operators are made aware of  the inherent hazards of operating a hot oil filtering system, partic