MULTI-DECK FRESH PRODUCE CASES 
 
CVW-EXA184 / CVW-EXA124 CVW-EXA284 / CVW-EXA224 
 
(H: 80 7/8”, L: 96 3/8”) / (H: 80 7/8”, L: 144 5/8”) (H: 84 7/8”, L: 96 3/8”) / (H: 84 7/8”, L: 144 5/8”) 
 
 
 
INSTALLATION & SERVICE MANUAL 
 
REMOTE TYPE DISPLAY CASE 
 
 
2010                                                                                                                                                                                                                                 
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        Activity Safety Precautions    In order to prevent any injuries to person, equipment and/or damage to the SANYO Cases, sections requiring  additional care to be undertaken will have one or all of the following safety reminders:    Red Safety Mark (Safety Mark A)  Extreme caution and care must be exercised when conducting this operation to ensure personal  A  and equipment safety, and to prevent product damage.   Failure to exercise extreme caution may result in severe personal injury and/or equi
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                          TABLE OF CONTENTS  1 SPECIFICATIONS ..................................................................................................................................................5  1.1 CVW-EXA284 / CVW-EXA224........................................................................................................................5  1.2 CVW-EXA184 / CPW-EXA124.........................................................................................................................6  2 DIMENSIONS
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                            6 CARE AND CLEANING GUIDELINES.............................................................................................................21  6.1 EXTERIOR PANELS (DAILY CLEANING)............................................................................................................21  6.2 MIRRORS, FLUORESCENT LAMPS, DRAIN TRAP (MONTHLY CLEANING).........................................................21  6.3 HONEYCOMB ASSEMBLIES (AT LEAST EVERY 3 MONTHS) ................................
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                          1 Specifications  1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”)  Model Name CVW-EXA284 CVW-EXA224     General  Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce)  Cooling Capacity: 1224 BTU/h/ft. (2,880W) 1224 BTU/h/ft. (4,321W)  Discharge Air: 34°F (1.11°C) 34°F (1.11°C)  Evaporator Temperature: 28°F (-2.22°C) 28°F (-2.22°C)  Defrost (Off-cycle) Medium Temperature  Medium Temperature     Frequency: (times per day) 6, once every 
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                            1.2 CVW-EXA184 (H: 80 7/8”, L: 96 3/8”) / CVW-EXA124 (H: 80 7/8”, L: 144 5/8”)  Model Name CVW-EXA184 CVW-EXA124     General  Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh produce)  Cooling Capacity:  1146 BTU/h/ft. (2682W) 1146 BTU/h/ft. (4195W)  Discharge Air: 34°F (1.11°C) 34°F (1.44°C)  Evaporator Temperature: 28°F (-2.22°C) 28°F (-2.22°C)  Defrost (Off-cycle) Medium Temperature  Medium Temperature     Frequency: (time per day) 6, once every 4 hours 6, once ov
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                          CVW-EXA284 / CVW-EXA224    2 Dimensions  2.2 Footprint  2.1 External Dimensions        ① Waste Outlet    ② Electrical Connection    * Dimensions given in inches and millimeters (mm in parentheses).    ③ Refrigeration Outlet                                                                                                                                                                                                                                                                                   
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                          CVW-EXA184 / CVW-EXA124      2.4 Footprint  2.3 External Dimensions        ①      Waste Outlet    * Dimensions given in inches and millimeters (mm in parentheses).    ②      Electrical Connection    ③      Refrigeration Outlet                                                                                                                                                                                                                                                                                
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                          3 Unloading and Carpentry Procedures    3.1 NSF Certification  The SANYO Cases described in this manual are built to meet the requirements of American National Standard/NSF International  Standard 7. Each SANYO Case bears a nameplate identifying the type of application for which it was certified:  Type I display refrigerator/freezer: Intended for use in an area where the environmental conditions are controlled and  maintained so that the ambient temperature typically does not exceed 75°F.  3.2
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                          3.5 Aligning Cases   WARNING  SANYO Cases are heavy and bulky, and require at least two people for unloading, moving, and installation.  Do not walk on the top of the SANYO Cases. Walking on the top of the SANYO Case may lead to serious injury and/or damage to  the SANYO Case.   Do not place anything on the top of the SANYO Case or use the top of any SANYO Case for short- or long-term storage.  1. Review layout drawings for spaces where SANYO Cases are to be installed.  2. Based on the layout 
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                          3.7 Joining Instructions    3.7.1 Applying gasket (for connecting cases or installing side panels).     ① Make sure that all SANYO Cases are resting level.  ② Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.).  ③ Remove all Rear Interior Panels, Wire Racks, Deck Pans, and Front Air Grilles from the far right and left ends of  each case being joined.  ④ Thoroughly clean all surfaces where the gasket will be placed to remove anything that might a
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                          3.7.2 Connecting cases.   ① Apply gasket as described above.   ② Connect cases by using the  attached bolts, joint covers, and  nuts.                                                                                      Silicone seal                Note: Connection point must    be silicone sealed.        Note: Gasket ends that are open must  be sealed off by applying silicone    at the installation site.                                12                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                          ① Gasket    ② M8 Bolts  ③ Side Cover  3.8 Installing Patch Ends  ④ Suction Lamp Cover Joint    ⑤ M5 Bolts  CVW-EXA284/224      CVW-EXA184/124                                                       1. Apply gasket to case body (per previous instructions).  2. If present, remove protective film from inside wall of Patch  End.  3. Place Patch End to line up with bolt holes.  4. From inside unit ratchet in M8 & optional M5 bolt into Patch  End until secure.  Apply silicone sealant inside  5. Apply 
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                          3.9 Installing Kickplate                                            1.  Align the mounting hole in the Kickplate with the slot in the Kickplate Mounting Bracket on the SANYO Case  and tighten accordingly.    14                                                                                                                                                                                                                                                                                                
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                          3.10 Installing Handrail and Bumper                                    Attaching the Bumper  1. Attach Maintenance Bumper (length 39-3/8 inches) to Bumper Brackets over the electrical  connection box (“Raceway”) on each SANYO Case. The Raceway is located on the right end of each  SANYO Case.  2. Attach Full-Length Bumpers between Maintenance Bumpers on separate SANYO Cases, and also  between Maintenance Bumpers and Patch Ends.  3. Cut Full-Length Bumpers to size on-site. Cut to correct size so
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                          4 Refrigeration, Plumbing & Electrical Procedures  4.1 Piping (Plumbing, Refrigeration)   ●  U-trap installation  Install U-trap referring to the drawing below.                                   Part Name Part Number    ① Drain Screen 8FL2162000500    ② O-Ring 8FL2646000100    ③ Drain Trap 8FL2658000200                          ● Sealing the refrigerant pipe opening    Seal pipe completely.    Insufficient sealing may cause the following problems:     Insufficient cooling     Excessive frost
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                          4.2  Electrical Data  Please refer to Specifications section and nameplate attached to merchandiser for electrical information.    4.3 Electrical – Guidelines & Precautions  All wiring and electrical field work must comply with the National Electrical Code (“NEC”) and other applicable local codes.   All electrical connections must be made inside the raceway area.    4.4 Wiring  4.4.1 Wiring Color Code                         WARNING!   While undertaking any electrical work, ensure that the cas
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                          4.4.2 Wiring Diagram    CVW-EXA284/184  CVW-EXA224/124    18                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                          5 Operation  5.1 Load Limits  In order to maintain proper temperature and unit performance, the Dual Air Curtains in each SANYO Case must remain  unobstructed:   Do not stock shelves beyond the marked load limits.   Do not block Honeycombs or Return Air Grilles.   Do not block airflow in any other way (with signs, tools, packages, etc.)  Failure to follow these precautions will lead to insufficient temperature control, airflow spoilage, merchandise compromise,  and excessive frost.      COR
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                          Installing FDA/NSF Thermometer      Magnet                                                                  Suggested locations for the thermometer required by NSF/ANSI 7 and the FDA Food  Code are indicated above. It is the responsibility of the Purchaser/End User of the  SANYO Case to determine the location within the food storage area that best meets  these code requirements.    20