Streszczenie treści zawartej na stronie nr. 1 
                    
                        book.book  Page 1  Sunday, September 11, 2011  10:24 PM
Dell PowerVault MD3200i and
MD3220i Storage Arrays
 Deployment Guide                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        book.book  Page 2  Sunday, September 11, 2011  10:24 PM Notes, Cautions, and Warnings  NOTE: A NOTE indicates important information that helps you make better use of  your computer.  CAUTION: A CAUTION indicates potential damage to hardware or loss of data if  instructions are not followed.  WARNING:  A WARNING indicates a potential for property damage, personal  injury, or death. ____________________ Information in this publication is subject to change without notice. © 2011 Dell Inc. All right
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        book.book  Page 3  Sunday, September 11, 2011  10:24 PM Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 7 System Requirements . . . . . . . . . . . . . . . . . . . 7 Management Station Requirements . . . . . . . . . 7 Introduction to Storage Arrays . . . . . . . . . . . . . . 8 2 Hardware Installation . . . . . . . . . . . . . . . 11 Planning the Storage Configuration. . . . . . . . . . .  11 Connecting the Storage Array . . . . . . . . . . . . . .  12 Cabling the Storage
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        book.book  Page 4  Sunday, September 11, 2011  10:24 PM 3 Installing PowerVault MD Storage Software . . . . . . . . . . . . . . . . . . . . . . . . . 27 Graphical Installation (Recommended). . . . . . .  28 Console Installation. . . . . . . . . . . . . . . . .  30 Silent Installation . . . . . . . . . . . . . . . . . .  30 Upgrading PowerVault MD Storage Software . . . . .  31 4 Post Installation Tasks. . . . . . . . . . . . . .  33 Before You Begin. . . . . . . . . . . . . . . . . . . . .  33 i
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        book.book  Page 5  Sunday, September 11, 2011  10:24 PM Uninstalling PowerVault MD Storage Software From Linux . . . . . . . . . . . . . . . . . . . . . . . .  54 A Appendix—Manual Configuration  of iSCSI . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Step 1: Discover the Storage Array  (Out-of-band Management Only) . . . . . . . . . . . .  56 Default Management Port Settings . . . . . . . .  56 Automatic Storage Array Discovery . . . . . . . .  57 Manual Storage Array Discovery . . . . 
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        book.book  Page 6  Sunday, September 11, 2011  10:24 PM Step 7: Connect to the Target Storage Array From  he Host Server . . . . . . . . . . . . . . . . . . . . . .  70 Step 8: (Optional) Set Up In-Band Management. . . . .  74 B Appendix—Using Internet Storage  Naming Service . . . . . . . . . . . . . . . . . . . . 75 C Appendix—Load Balancing . . . . . . . . . .  77 Load Balance Policy . . . . . . . . . . . . . . . . . . .  77 Round Robin With Subset. . . . . . . . . . . . . .  77 Least Queue D
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        book.book  Page 7  Sunday, September 11, 2011  10:24 PM 1 Introduction This guide provides information about deploying Dell PowerVault MD  MD3200i and Dell PowerVault MD3220i storage arrays. The deployment  process includes: • Hardware installation • Modular Disk Storage Manager (MDSM) software installation • Initial system configuration Other information provided include system requirements, storage array  organization, and utilities.   NOTE: For more information on product documentation see,  
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        book.book  Page 8  Sunday, September 11, 2011  10:24 PM • Display resolution of 1024x768 with 16 million colors (1280x1024 32-bit  recommended) • Microsoft Windows, Red Hat Enterprise Linux, and SUSE Linux  Enterprise Server.   NOTE: Operating system installations can be either native or hypervisor guest  configurations.   NOTE: Supported hypervisors include Microsoft Hyper-V, Citrix XenServer,  and VMware. For information about the supported versions, see the Support  Matrix at support.dell.com
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        book.book  Page 9  Sunday, September 11, 2011  10:24 PM Unconfigured capacity comprises of physical disks not already assigned to a  disk group. When a virtual disk is created using unconfigured capacity, a disk  group is automatically created. If the only virtual disk in a disk group is  deleted, the disk group is also deleted. Free capacity is space in a disk group  that is not assigned to any virtual disk. Data is written to the physical disks in the storage array using RAID  technology. RAID
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        book.book  Page 10  Sunday, September 11, 2011  10:24 PM 10 Introduction                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        book.book  Page 11  Sunday, September 11, 2011  10:24 PM 2 Hardware Installation Before using this guide, ensure that you review the instructions in the: • Getting Started Guide—The Getting Started Guide that shipped with  the storage array provides information to configure the initial setup of  the system.  • Planning section of the Owner’s Manual—The planing section provides  information about important concepts you must know before setting  up your storage solution. See the Owner’s Manual at 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        book.book  Page 12  Sunday, September 11, 2011  10:24 PM Connecting the Storage Array  The storage array is connected to a host using two hot-swappable RAID  controller modules. The RAID controller modules are identified as RAID  controller module 0 and RAID controller module 1. Each RAID controller module has four iSCSI In port connectors that provide  Ethernet connections to the host server or switches. Each RAID controller  module also contains an Ethernet management port and a SAS Out port. 
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        book.book  Page 13  Sunday, September 11, 2011  10:24 PM Direct-Attached Configurations You can connect the Ethernet ports of the host servers directly to the storage  array RAID controller module iSCSI ports. Single Path Data Configurations With a single path configuration, a group of heterogeneous hosts can be  connected to the storage array through a single physical Ethernet port. Since  there is only one port, there is no redundancy, although each iSCSI portal  supports multiple connections.
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        book.book  Page 14  Sunday, September 11, 2011  10:24 PM Figure 2-1 shows a non-redundant cabling configuration to the RAID  controller modules using a single path data configuration. Figure 2-1. Four Hosts Connected to a Single Controller Server 1 Server 2 Server 3 Server 4 Storage array Corporate, public,  or private network 14 Hardware Installation                                                                                                                                                   
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        book.book  Page 15  Sunday, September 11, 2011  10:24 PM Figure 2-2 shows two hosts connected to a single controller array. Figure 2-2. Two Hosts Connected to a Single Controller Server 1 Server 2 Storage array Corporate, public,  or private network Hardware Installation 15                                                                                                                                                                                                                                  
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        book.book  Page 16  Sunday, September 11, 2011  10:24 PM Figure 2-3 shows eight stand-alone hosts supported in a dual controller array  configuration with a single data path. Figure 2-3. Eight Hosts in a Dual-Controller Configuration Up to 8 hosts Server 1 Server 3 Server 4 Server 8 Server 2 Storage array Corporate, public,  or private network 16 Hardware Installation                                                                                                                                  
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        book.book  Page 17  Sunday, September 11, 2011  10:24 PM Dual-Path Data Configuration In Figure 2-4, up to four servers are directly attached to the RAID controller  modules. If the host server has a second Ethernet connection to the array,  it can be attached to the iSCSI ports on the array's second controller.  This configuration provides improved availability by allowing two separate  physical paths for each host, which ensures full redundancy if one of the  paths fail. In Figure 2-5, up to f
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        book.book  Page 18  Sunday, September 11, 2011  10:24 PM Figure 2-4. Four Hosts Connected to Two Controllers Server 1 Server 2 Server 3 Server 4 Storage array Corporate, public,  or private network 18 Hardware Installation                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        book.book  Page 19  Sunday, September 11, 2011  10:24 PM Figure 2-5. Four Hosts Connected in a Dual-Controller Configuration Four node cluster server Storage array Corporate, public,  or private network Hardware Installation 19                                                                                                                                                                                                                                                                                 
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        book.book  Page 20  Sunday, September 11, 2011  10:24 PM Network-Attached Configurations You can also cable the host servers to the RAID controller module iSCSI ports  through industry-standard 1GB Ethernet switches. An iSCSI configuration  that uses Ethernet switches is frequently referred to as an IP SAN. By using an  IP SAN, the PowerVault MD3200i series storage array can support up to 64  hosts simultaneously. This configuration supports either single- or dual-path  data configurations and e