Resumo do conteúdo contido na página número 1 
                    
                        MODEL 158A 909GF197B   
 
 
 
 
INSTRUCTION MANUAL 
 
 
FOR 
 
MODEL 158A 
 
LEVEL-TEL 
 
 
 
We do our level best 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
Probe, Cable and Conduit Outlet Box 
shown for illustration only. 
 
Must be ordered separately. 
 
 
 
 
 
 
 
INSTRUCTION MANUAL NUMBER 
 
 
 
    Industrial Products Division 
909GF197B 
    1602 Mustang Drive 
 
    Maryville, Tennessee 37801 
P-2410 
    Phone: (865) 981-3100  Fax: (865) 981-3168 
 
   - 1 - 
                             
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        MODEL 158A 909GF197B      Table 3 – DISPLAY HOUSING AND  Section I – DESCRIPTION  INDICATION    Desig. Description  1.1 GENERAL  A Water tight enclosure without  The Robertshaw Model 158A Level-Tel is a  indicator.  capacitance operated DC current transmitter with  Meets NEMA Type 4 and CSA  noninteracting and independent zero and span  Enclosure 5.  adjustments internally located.  The transmitter is  B Water tight housing with indicator.  remotely mounted from the probe with a triax  Meets NEM
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        MODEL 158A 909GF197B      1.3 TRIAXIAL CABLE ACCESSORY ITEMS                     032KE03X-XX  032KE090-05     (5 ft long)  GENERAL PURPOSE (polyethylene insulated) 032KE090-10   (10 ft long)  Triax Cable with probe connection conduit GENERAL PURPOSE (polyethylene insulated)  outlet box.  (Recommended for use with Triax Cable in explosion proof flexible conduit  customer supplied rigid or flexible conduit.)  (protective armor) with seal fitting and probe  connection conduit outlet box.  Maximum  
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        MODEL 158A 909GF197B      2.4 ENCLOSURE  Section II - SPECIFICATIONS    Water Tight ............... NEMA 4, CSA Enclosure 5,  2.1 ENVIRONMENTAL  Polyurethane painted cast aluminum  Ambient Temperature Limits.......-40 ° F to +160 ° F  Explosion Proof...Class I, Division 1, Groups C, D;  Class II, Division 1, Groups E, F, G;  Vibration Limits ................ ± 2 G from 10 to 200 Hz  Polyurethane painted cast aluminum    2.2 ELECTRICAL  Weatherproof ..... NEMA 12, 13, CSA Enclosure 3,  Polyuretha
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        MODEL 158A 909GF197B      3.3 TRANSMITTER UNIT MOUNTING  Section III - INSTALLATION    The Model 158A is designed for vertical surface  3.1 GENERAL  mounting: e.g. wall, panel or column.  Choose the  mounting location to avoid extremes of ambient  Examine the instrument for possible shipping  temperature or vibration (see Specifications,  damages.  IMPORTANT: If for any reason it is  Section II).  determined that parts should be returned to the    factory, please notify the nearest Robertshaw  3
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        MODEL 158A 909GF197B                                                                                                         MM        INCHES                     SEE FIGURE 5 FOR DIMENSIONS OF  PROBE MOUNTED CONDUIT OUTLET BOX.                   FIGURE 1          MOUNTING DIMENSIONS FOR MODEL 158A WATER TIGHT ENCLOSURE WITH     AND WITHOUT INDICATOR, MODELS 158A – (  ) (  ) – A1 AND 158A – (  ) (  ) B1.                 - 6 -                                                                        
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        MODEL 158A 909GF197B                                                                                                                       MM       INCHES           SEE FIGURE 5 FOR DIMENSIONS OF PROBE     MOUNTED CONDUIT OUTLET BOX.                 FIGURE 2          MOUNTING DIMENSIONS FOR MODEL 158A EXPLOSION PROOF ENCLOSURE WITH     AND WITHOUT INDICATOR, MODELS 158A – (  ) (  ) – C1 AND 158A – (  ) (  ) – D1.              - 7 -                                                                 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        MODEL 158A 909GF197B                                                                                                      TERMINAL     TERMINAL CONNECTION REMARKS     PROBE TRIAX WHITE LEAD      SHLD TRIAX RED LEAD       GND TRIAX BLACK LEAD     1 N (  ) SUPPLY  SEE RATING PLATE   2 H (+) SUPPLY  (120 VAC, 240 VAC OR 26.5 VDC)     GND CHASSIS GROUND      3 (  ) OUTPUT SIGNAL  SEE NOTE 1     4 (+) OUTPUT SIGNAL          NOTES:          1. REMOVE JUMPER ACROSS OUTPUT TERMINALS 3 AND 4 WHEN RECORDE
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        MODEL 158A 909GF197B                                                                                                   MILLIMETER     INCH                          SEE FIGURE 5 FOR DIMENSIONS OF PROBE     MOUNTED CONDUIT OUTLET BOX.                    FIGURE 4          MOUNTING DIMENSIONS FOR LARGE WEATHERPROOF ENCLOSURE WITH INDICATOR (USED WITH     OPTIONAL ALARMS) MODEL 158A – (  ) (  ) – E (  ).                 - 9 -                                                                            
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        MODEL 158A 909GF197B                                                            FIGURE 5          DIMENSIONS OF PROBE MOUNTED CONDUIT OUTLET BOX SUPPLIED WITH TRIAX CABLE.   (TRIAX CABLE ORDERE D SEPARATELY)                                                                                         FIGURE 6          ELECTRICAL CONNECTIONS FOR LARGE WEATHERPROOF ENCLOSURE,     MODEL 158A – (  ) (  ) – E (  ).       - 10 -                                                                                
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        MODEL 158A 909GF197B         FIELD WIRING     TERMINAL CONNECTION REMARKS     PROBE TRIAX WHITE LEAD      TB2  SHLD TRIAX RED LEAD         GND TRIAX BLACK LEAD      G CHASSIS GROUND      1 N (  ) SUPPLY SEE RATING PLATE     (120 VAC, 240 VAC OR 26.5 VDC)  2 H (+) SUPPLY     TB7 3 (  ) OUTPUT  SEE NOTES 2 AND 5     4 (+) OUTPUT     5     6   NO CONNECTION SEE NOTE  5  7     8     9 N.C.     10 COM.     TB8  OPTIONAL NO. 1 ALARM CONTACTS  11 N.O.       12 N.C.     SEE NOTES 1 AND 3  13 COM.     14
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        MODEL 158A 909GF197B                                                                                             NOTES:     1. IN FIGURE 1, THE TRANSMITTER IS CSA CERTIFIED FOR HAZARDOUS LOCATIONS, CLASS I, DIVISION 1, GROUPS C & D;     CLASS II, DIVISION 1, GROUPS E, F & G.  THE PROBE IS INTRINSICALLY SAFE FOR CLASS I, DIVISION 1, GROUPS A, B, C &  D; CLASS II, DIVISION 1, GROUPS E, F & G.     IN FIGURE 2, THE TRANSMITTER IS CSA CERTIFIED FOR ENCLOSURE 5.  THE PROBE IS INTRINSICALLY SAFE FOR  C
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        MODEL 158A 909GF197B      Alarm Module No. 2.  Refer to Figure 9 and the  Section IV – OPERATION  following paragraphs for detailed instructions on    how to change the links to obtain the desired  4.1 CALIBRATION ADJUSTMENTS  mode.  The supply voltage to the instrument  All the adjustments for calibrating the Model 158A  should be disconnected when making this  Level-Tel are located on the printed circuit board  change.  assembly and consist of the following (see Figure    8):  4.2.1 Low Level 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        MODEL 158A 909GF197B      CALIBRATION PROCEDURE d) Change the process level in the tank to the  desired 100% (high) level and adjust the  4.3.1 Zero and Span Calibration  Coarse and Fine Span until the output or  With the Model 158A Level-Tel mounted and  meter indicates 100% (5, 10, 20 or 50 mA  electrical connections made, the following  depending on the output signal range of the  procedures should be followed in calibrating the  Model 158A Level-Tel being used).   instrument:  Clockwise rota
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        MODEL 158A 909GF197B        Section IV – SPARE PARTS            SPARE PARTS        DESIG. DESCRIPTION SUPPLY OUTPUT USED ON PART NO.          1-5 mADC 158A-A1-XX 044KB766-01        26.5 VDC 4-20 mADC 158A-B1-XX 044KB766-04          10-50 mADC 158A-C1-XX 044KB766-07      0-10 mADC 158A-D1-XX 044KB766-10        1-5 mADC 158A-A2-XX 044KB766-02          TB2 TRANSMITTER 4-20 mADC 158A-B2-XX 044KB766-05  120 VAC       PRINTED CIRCUIT ASSY 50/60 Hz    10-50 mADC 158A-C2-XX 044KB766-08        0-10 mADC 
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        MODEL 158A 909GF197B                                                                                                                                                                                         Q-3882  (1/03)   Printed in U.S.A.       - 16 -