CONTENTS Section Title Page 4.CONSTRUCTlONANDFUNCTlON l l l l l l l l l l l l l l l l l l 7 4-l CONSTRUCTlON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 J-2 FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4-3 DESCRIPTION andGENERATOROPERATlON l . l l l l . . . l l l l l l 16 5. SAFETY PRECAUTIONS l o l l l l l l l l l l l l l l - l l l l l 18 6. RANGE OF APPLICATIONS l l l l l l l l l l l l l l l l l l l l l 19 7. MEASURING PROCEDURES l l l l l
Resumo do conteúdo contido na página número 3
-02-
Resumo do conteúdo contido na página número 4
1. SPECIFICATIONS Model RGV12000 RGV13OOOT Brush, Self-exciting, Brush, Self-exciting, Type 2-pole, Single phase 2-pole, 3-phase 60Hz Rated frequency 12OV I 240V 12OV I 208V 8 Rated voltage E Q, Maximum output 12OOOVA 13OOOVA 2 . 1 OOOOVA Rated output 1 OOOOVA Power factor 1.0 0.8 A.V.R type C.T. type Voltage regulator Model EH65D EH63D V-Twin cylinder, Air-cooled, 4-stroke, Overhead valve engine Type Displacement 653 cm3 E z Maximum output 22 HP/ 3600 rpm 18 HP/ 3600 rpm
Resumo do conteúdo contido na página número 5
2. PERFORMANCE CURVES l RGV12000 / 60Hz (9.5 KW240V) (Hz) 63 HZ 62 61 .I1 ------------------------------------------ ,--- 60 \ (VI 250 (125) 24OVl12OV 240 (120) 230 (115) 220 I/~~~~~~~~~ (110) 4/4 112 Load Rated . RGV13000T / 60Hz (12OW208V) (Hz) 63 62 61 60 230 T 208V 220 t l/2 414 0 Rated Load -2-
Resumo do conteúdo contido na página número 6
3. GENERAL DESCRIPTION OF GENERATOR TANK CAP iLTANK COOLING AIR / INLET PORT /FUEL COCK BATTERY K STOPPER OIL FILLER CAP SPARK PLUG CAP CHbKE KNOB (RGV13000T only) CONNECTOR FOR REMOTE CONTROL (RGV12000 only) END COVER (RGV13000T only) OIL GAUGE OIL DkAlN PLUG ‘ELECTRIC STARTER -3-
Resumo do conteúdo contido na página número 7
CONTROL PANEL (RGVI 2000) OIL PURESSURE VOLT METER WARNING LAMP NO-FUSE BREAKER PILOT LAMP HOUR METER \ I KEY SWITCH c AUTO IDEL SWITCH EARTH (GROUND) CONNECTOR AC RECEPTACLE TERMINAL FOR REMOTE CONTROL :-. (RGVI 3000T) OIL PURESSURE VOLT METER WARNING LAMP NO-FUSE BREAKER PILOT LAMP HOUR METER \ / KEY SWITCH I AC RECEPTACLE AC OUTPUT TERMINAL EARTH (GROUND) TERMINAL -4-
Resumo do conteúdo contido na página número 8
SERIAL NUMBER Serial number is stamped on the label stuck on the end cover. NOTE : Always specify serial number when inquiring about the generator or ordering spare parts in order to get correct parts and accurate service. (RGV13000T) (RGV12000) SERIAL NUMBER stamped label SERIAL NUMBER stamped label -5-
Resumo do conteúdo contido na página número 9
4. CONSTRUCTION AND FUNCTION 4-l CONSTRUCTION END COVER (RGV13000T only) BRUSH HOLDER STATOR COMPLETE \ STATOR BOLT \ REAR COVER I ROTOR COMPLETE ‘y \ FRONT COVER I \ / I’ . . I BALL BEARING TROUGH BOLT MOUNT RUBBER SLIP RING 4-2 FUNCTION 4-2-l STATOR The stator consists of a laminated silicon steel sheet core, a main coil and a condenser coil which are wound in the core slots. The condenser coil excites the rotor field coil which generates AC voltage in the main coil. -
Resumo do conteúdo contido na página número 10
4-2-2 ROTOR The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core. DC current in the field coil magnetizes the steel sheet core. Two permanent magnets are provided for the primary exciting action (RGV13OOOT). Slip rings are provided on the rotor shaft to receive DC exciting current from AVR (RGV12000) and diode unit (RGVl3000T). A surge absorber is mounted inside of the I insulator. 4-2-3 BRUSH I BRUSH HOLDER An exciting current i
Resumo do conteúdo contido na página número 11
4-2-4 CURRENT TRANSFORMER I DIODE UNIT (RGV13000T only) The current transformer and diode unit will perform a role to step up the voltage lowered by the load and stabilize the output voltage. CURRENT TRANSFORMER DIODE UNIT 4-2-5 A.V.R (AUTOMATIC VOLTAGE REGULATOR) (RGV12000 only) The automatic voltage regulator employs an electronic circuit to automatically regulate voltage. 4-2-6 ECU (ELECTRONIC CONTROL UNIT) ECU controls the start/stop of an engine enabling the fuel cut while sto
Resumo do conteúdo contido na página número 12
Description of Operation Function When the lubrication oil pressure drops below the safety limit (Oil pres- Warning lamp sure becomes less than 1 kg/cm2), the warning lamp turns on and off, and the engine stops automatically. The warning lamp turns off after 3 minutes. When the the engine started and reaches 1,050 rpm, the electric starter is automatically stopped. Electric starter control When the engine operating, the electric starter can not start. When the key switch or the remote c
Resumo do conteúdo contido na página número 13
4-2-8 OIL PRESSURE SWITCH .r? The oil pressure switch sends a signal to ECU to stop the engine when the engine oil pressure drops to 1 .O kg/cm2 4-2-9 RELIEF VALVE The relief valve begins to open when the engine’s oil pressure increases above 3.0 kg/cm2 OIL FILTER I CAMSHAFT OIL PRESSljRE SWITCH OIL PUMP FILTER 4-2-10 AC SWITCH (NO-FUSE BREAKER) The AC switch (no-fuse breaker) protects the generator from getting damage by overloading or short circuit in the appliance. The capacity of
Resumo do conteúdo contido na página número 14
4-2-l 1 AC Receptacle and Terminals AC receptacle and terminals are used for taking AC output power from the generator. A total of 4 kinds of receptacle and terminals, each varying in rated voltage and current from. another, are used. As many AC terminals as the receptacles, each matching the corresponding receptacle, are provided. The rated current for each receptacle and terminal is shown as follows; CAUTION Be careful not to use the receptacles and terminal beyond the specified ampera
Resumo do conteúdo contido na página número 15
n Check the amperage of the receptacles used referring to TABLE 1, and be sure not to take a current exceeding the specified amperage. n Be sure that the total wattage of all appliances dose not exceed the rated output of the gen- erator. Style Ampere Receptacle AC plug Description GFCI (Ground Fault Circuit NEMA NEMA up to20A interrupter) Receptacle, duplex 5-20R 5-2OP (RECl) NEMA NEMA Locking Receptacle up to 30A L!5-30R L5-30 P (REC2) NEMA NEMA Locking Receptacle up to 30A L14
Resumo do conteúdo contido na página número 16
If the RESET button pops out during operation, stop the generator immediately and call a qualified electrician for checking generator and the appliances. (2) CONNECTING TO DOMESTIC CIRCUIT (HOUSE WIRING) All Robin generators are a neutral ungrounded type. If a generator is to be connected to residential or commercial power lines, such as a stand-by power source during power outage, all connections must be made by a licensed electrician. Failure in connection may result in death, personal
Resumo do conteúdo contido na página número 17
.n CONNECTING B RECEPTACLE TRA&FER SWITCH m Ii c .n 42-l 2 3-PHASE APPLICATION (RGV13OOOT only) Connection of Power Cables I n Do not touch output terminals while the generator is running or the operator may suf- fer severe electric shock resulting in death. w Be sure to shut down the generator before connecting or changing connection of power cables to the generator. This generator has four output terminals of three phase, four wire system. Connect power cables to the generator ou
Resumo do conteúdo contido na página número 18
(1) 3-Phase application (208V) Connecting the power cable&o terminals U, V and W. 1 Generator rated output : 1OOOOVA 1 3-PHASE OUTPUT (2) Single phase higher voltage application (208V) -\ / Connect the power cables to-terminals U 0 u v w and V, V and W, and U and W. 0 L / Maximum one-second (l/2) of generator c 3 output can be utilized from each phase. 4 Generator rated output : SINGLE-PHASE OUTPUT 5760VA (208V x 27.7A) (3) Single phase lower application (120V) Connect the
Resumo do conteúdo contido na página número 19
4-3 DESCRIPTION of GENERATOR OPERATION 4-3-l PRIMARY EXCITING ACTION (RGV12000) When the generator is started, the perma- FC nent magnet on the engine rotates to genera- tor a voltage in the exciting coil. This voltage is regulated by a diode in the AVR to feed a current to the generator field EC ; coil. (FC). (See Fig. 4-1) The rotor is turned an electromagnet by that current and rotates so that voltage are gener- ENGINE MAGNETO ated in the stator coils (main coil and sub coil).
Resumo do conteúdo contido na página número 20
4-3-3 CURRENT TRANSFORMER CONTROL (RGV13000T) When the engine starts, a permanent magnet implanted in the rotor rotates, creating voltage in the main coil (MC). When a load makes contact with the coil, the load current passing through the primary coil of current transformer causes a magnetizing current to flow in ratio to the load current flowing through the current transformer primary coil. This magnetizing current passing through a diode to field coil creates a strong magnetic field in th