OPERATING MANUAL
AGILENT 603xA FAMILY
AUTORANGING SYSTEM DC
POWER SUPPLIES
AGILENT Part No. 5959-3342
* OPERATING MANUAL FOR MODELS
Agilent 6030A, Serials 2934A-01825 to 01829
3023A-01925 and above
Agilent 6031A, Serials 2934A-01821 to 01825
3026A-01921 and above
Agilent 6032A, Serials 3004A-05881 to 05885
3023A-06181 and above
Agilent 6033A, Serials 3004A-05092 to 05096
Resumo do conteúdo contido na página número 2
CERTIFICATION Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Bureau of Standards, to the extent allowed by the Bureau’s calibration facility, and to the calibration facilities of other International Standards Organization members. WARRANTY This Agilent Technologies hardware product is warranted against defect
Resumo do conteúdo contido na página número 3
Safety Summary The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability for the customer’s failure to comply with these requirements. GENERAL This product is a Safety Class 1 instrument (provided with a protective earth terminal
Resumo do conteúdo contido na página número 4
SAFETY SYMBOLS Direct current Alternating current Both direct and alternating current Three-phase alternating current Earth (ground) terminal Protective earth (ground) terminal Frame or chassis terminal Terminal is at earth potential. Used for measurement and control circuits designed to be operated with one terminal at earth potential. Terminal for Neutral conductor on permanently installed equipment Terminal for Line conductor on permanently installed equipment On (supply) Off (supply) Standby
Resumo do conteúdo contido na página número 5
Declaration Page DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN 45014 Manufacturer’s Name: Agilent Technologies Manufacturer’s Address: 150 Green Pond Road Rockaway, New Jersey 07866 U.S.A. declares that the Product Product Name: a) Single Output System Power Supply b) Autoranging Power Supply Model Number: a) Agilent 6030A, 6031A, 6032A, 6035A, 6033A, 6038A b) Agilent 6010A, 6011A, 6012B, 6015A, 6023A, 6028A conforms to the following Product Specifications: 1 Safety: IEC 348 19
Resumo do conteúdo contido na página número 6
Acoustic Noise Statement Herstellerbescheinigung Diese Information steht im Zusammenhang mit den Anforderungen der Maschinenlärminformationsverordnung vom 18 Januar 1991. * Schalldruckpegel Lp < 70 dB(A) * Am Arbeitsplatz * Normaler Betrieb * Nach DIN 45635 T. 19 (Typprüfung) Manufacturer’s Declaration This statement is provided to comply with the requirements of the German Sound Emission Directive, from 18 January 1991. This product has a sound pressure emission (at the operator position) < 70
Resumo do conteúdo contido na página número 7
Table Of Contents 1. General Information Introduction ..................................................................................................................................................11 Description....................................................................................................................................................11 Safety Considerations .................................................................................................................
Resumo do conteúdo contido na página número 8
Table Of Contents (continued) Error ..........................................................................................................................................................43 Local Operation.............................................................................................................................................43 Constant Voltage Operation ...................................................................................................................
Resumo do conteúdo contido na página número 9
Table Of Contents (continued) Remote Sensing.........................................................................................................................................69 Series Operation............................................................................................................................................69 FLT & Remote INH Connections ...............................................................................................................70 A 100 VA
Resumo do conteúdo contido na página número 10
Table Of Contents (continued) Register Functions...................................................................................................................................107 Status Programming Examples................................................................................................................108 Status Byte Register ..................................................................................................................................108 The R
Resumo do conteúdo contido na página número 11
1 General Information Introduction This manual contains specifications, installation instructions, and operating instructions for System Power Supply Models: Agilent 6030A, 6031A, 6032A, 6033A, 6035A, and 6038A. Refer to "Related Documents" for other information concerning these products. Description This system power supply is an autoranging GP-IB power supply. It uses power MOSFETs in a 20 kHz switching converter to provide an autoranging output characteristic with laboratory performance. Outp
Resumo do conteúdo contido na página número 12
A fault indicator (FLT) and remote inhibit (INH) circuit provides additional shutdown protection, should either the GP-IB and/or controller fail. The FLT circuit provides the user with a means of knowing the status of any unmasked fault register bit independently of the SRQ function available through the GP-IB. You don’t have to rely on the controller to inform you of a fault within the power supply. The INH circuit (which is also independent of the GP-IB) controls the RI bit in the fault regist
Resumo do conteúdo contido na página número 13
1494-0060 Rack slide kit, non tilting 5060-2865 Service kit, includes extenders for control and power mesh boards, three cables to allow GP-IB and PSI boards to lie on table outside unit, and control board test connector. 5060-2866 FET service kit. Includes FETs and all components that should be replaced with FETs. 59510A Relay Accessory 59511A Relay Accessory (Polarity Reversing) 5062-3960 Rack mounting adapter kit for side mounting one 7-inch high cabinet, includes one rack flange and on
Resumo do conteúdo contido na página número 14
The serial number prefixes listed on the front of this manual indicate the versions of the supplies that were available when the manual was issued. If the serial prefix of your supply is not listed in this manual, the manual may include a yellow "Manual Change’’ sheet. That sheet updates this manual by defining any differences between the version of your supply and the versions included here, and may also include information for correcting any manual errors. Note that because not all changes to
Resumo do conteúdo contido na página número 15
Related Documents The following documents may be useful for your GP-IB systems. The Agilent documents can be ordered from your local Agilent Sales Office. Agilent 6033A/38A Service Manual, Agilent part number 5959-3346. Agilent 6030A/31A/32A/35A Service Manual, Agilent part number 5959-3344. Tutorial Description of the Agilent Technologies Interface Bus, Agilent Part Number 5952-0156, November 1987 ANSI/IEEE Std 488.1-1987, IEEE Standard Digital Interface for Programmable Instrumentation, av
Resumo do conteúdo contido na página número 16
Table 1-1. Performance Specifications Agilent Technologies Model 6033A 6038A DC Output: Voltage, current and power spans indicate range Volts 0-20 V 0-60 V over output may be varied using front panel controls. Amps 0-30 A 0-10 A Maximum Power 200-240 W 200-240 W Load Effect (Load Regulation) Voltage load effect is given for a load Voltage 0.01% + 2 mV 0.01% + 3 mV current change equal to the current rating of the supply. Current load effect is given for a load voltage change equal to the volt
Resumo do conteúdo contido na página número 17
6030A 6031A 6032A 6035A NOTES. 1. Not specified 0-200 V 0-20 V 0-60 V 0-500 V 0-17 A 0-120 A 0-50 A 0-5 A 2. Initially, for each degree 1000-1200 W 840-1072 W 1000-1200 W 1000-1050 W below 20°C the ripple 0.0l% + 5 mV 0.0l% + 3 mV 0.0l% + 5 mV 0.0l% + 40 mV increases 2.4 mV/°C. After loadis applied 0.0l% + l0 mA 0.0l% + l5 mA 0.0l% + l0 mA 0.03%+34 mA for 15 minutes, the increase becomes 1.4 mV/°C. 0.0l% + 5 mV 0.0l% + 2 mV 0.0l% + 3 mV 0.0l% + l3 mV 3 After a
Resumo do conteúdo contido na página número 18
Table 1-2. Supplemental Characteristics (continued) DC Floating Voltage: Either output terminal may be floated up to the following voltage (including the output voltage) from earth ground: ± 240 Vdc on Models 6031A, 6032A, 6033A, and 6038A ± 550 Vdc on Models 6030A and 6035A Exceeding these voltage can result in damage to the equipment. Remote Sensing: The power supply maintains specifications at the load with up to 0.5 volt drop per load lead. Operation with up to 2 volts per load lead is pos
Resumo do conteúdo contido na página número 19
Figure 1-1. Output Characteristic Curve Agilent Model 6030A 6031A 6032A 6033a 6035A 6038A Vp1 200 V 20 V 60 V 20 V 500 V 60 V Ip1 5 A 50 A 17.5 A 10 A 2 A 3.3 A Vp2 120 V 14 V 40 V 14 V 350 V 40 V Ip2 10 A 76 A 30 A 17.2 A 3 A 6 A Vp3 60 V 7 V 20 V 6.7 V 200 V 20 V Ip3 17 A 120 A 50 A 30 A 5 A 10 A General Information 19
Resumo do conteúdo contido na página número 20
General Information 20