Resumo do conteúdo contido na página número 1 
                    
                        INSTRUCTION MANUAL
FOR
DIGITAL BLOOD PRESSURE MONITOR
REF CH-463E
CITIZEN is a registered trademark of Citizen Holdings Co., Japan.
CITIZEN es una marca registrada de Citizen Holdings Co., Japón.
Design and Specification are subject to change without notice.
0801                                                                                                                                                                                                                                             
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Contents  3 - GENERAL REMARKS  5 - PRECAUTIONS FOR USE AND MAINTENANCE  8 - UNIVERSAL DESIGN  9 - IDENTIFICATIONS OF PARTS 10 - LOADING THE BATTERIES 11 - USING AC ADAPTER (OPTION) 12 - REMOVING THE BATTERIES 12 - RESETTING OPERATION  13 - SETTING THE CLOCK 17 - MEASURING YOUR BLOOD PRESSURE 19 - TIPS FOR OBTAINING ACCURATE MEASUREMENTS 23 - AUTOMATIC CHANGEOVER FEATURE 23 - HOW TO CALL UP THE VALUES STORED IN MEMORY TO THE  DISPLAY 24 - HOW TO CALL UP THE DATA STORED IN MEMORY 25 - HOW TO DELET
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        GENERAL REMARKS General remarks on blood pressure and blood pressure measurement 1. To defl ate the cuff quickly, press the “START/STOP” switch. 2. The attached cuff is suitable for arm circumferences of 20-32 cm. 3. When attaching the cuff, the air hose should be placed on the inside of your arm on top  of the artery. 4. Self measurement is not therapy! In no event should you change the dosage of your  medication prescribed by your physician. 5. As preparation for measuring your blood pressure, 
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        English GENERAL REMARKS 9. DO NOT measure blood pressure when the cuff has been on your arm for a few minutes  or more. During this time, your arm will have built up a higher blood pressure and you will  not get valid reading. 10. The fi gure below shows the blood pressure classifi cations under the WHO standards. Remarks: The graph is not exact, but may be  used as a guide in understanding  non-invasive blood pressure  measurements. The device is only  intended for use with adults. Defi nitions an
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        PRECAUTIONS FOR USE AND MAINTENANCE Precautions for use 1. If you suffer from heart disease, high blood pressure or other circulatory disease, consult  your physician before using the monitor. 2. If the cuff pressure feels abnormal or you experience any other irregularity while using the  cuff, reduce the pressure immediately by pressing the “START/STOP” switch and then  consult the sales outlet where you purchased the monitor. 3. If you think the measurement is abnormal or if measurement makes 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        English PRECAUTIONS FOR USE AND MAINTENANCE 15. Be sure to use this unit only for measuring blood pressure. DO NOT use it for any other  purpose. 16. DO NOT use this unit on infants. 17. Blood pressure measurement may not be possible for anyone with common arrhythmias  such as atrial or ventricular premature beats or atrial fi brillation. Maintenance Precautions 1. DO NOT store the blood pressure monitor in locations exposed to direct sunlight, high  temperatures (over 60°C), low temperatures (be
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        PRECAUTIONS FOR USE AND MAINTENANCE Nature and frequency of maintenance: This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. Protect the nature environment: Please help to protect natural environment by respecting national and/or local recycling  regulations when disposing of the battery and the product at the end of their useful live. WEEE MARK If you want to dispos
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        English   ) e s   - n m o o e r i t t - t t o     y u f t o & s b   a   s   h   r e e t e t c a   a b t d h s d i m   t t t n w   u n y n N e a r e s / m o e   m   r e m e u r e e r s s u u s s m g s s e a r   a e r l p M e u e   t  f d / a r m p o e s l   s n r o L p e e l t e UNIVERSAL DESIGN This product has been developed with the concept of Universal Design to ensure safe and  easy use for a broader range of users. The product’s shape and color was designed to  portray “warmth” and “gentlen
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        IDENTIFICATION OF PARTS Component names Main Unit Date display Time display Systolic blood pressure  Alarm icon display Cuff holding pocket Diastolic blood  pressure display Pulse display Memory icon Measurement icon Battery icon Air hose socket START/STOP  Switch MODE Switch a Stand-by SET Switch MEMORY Switch Air hose Battery  cover Knob Release lever Cuff Air hose  Cuff connector RESET switch - Eng 9 - English                                                                                    
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        English LOADING THE BATTERIES (Batteries supplied with the unit should be loaded in compartment before putting the Blood  pressure monitor in use.) 1 Open the cover of battery compartment.  Pressing the hook down, pull the cover toward you to open. Hook Battery  compartment Battery  compartment  cover Lug (projecting  section) 2 Place batteries in the compartment.  Put the batteries paying attention to the positive  4 “AA” batteries and negative terminal symbols m and ,.  * If the Blood pressure
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        USING AC ADAPTER (OPTION) Using the optional dedicated AC adapter for the CITIZEN blood pressure monitor (CH-463E)  allows you to measure your blood pressure without having to worry about the amount of  remaining charge in the batteries. 1. Insert the AC adapter plug into  the socket on the blood pressure  AC adapter socket monitor. 2. Plug the AC adapter into a mains  power outlet. AC adapter plug AC ADAPTER (OPTION) Ref: AC-230CZ • If you plan to use the AC adapter for an extended period of ti
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        English REMOVING THE BATTERIES • When the icon  is displayed, or where the clock is no longer shown or nothing appears  in the display, replace the old batteries with four new ones. All four batteries should be  changed at once. • The memory is erased if the batteries are removed for replacement. It is recommended to  make note of the data stored in memory prior to changing batteries. • Do not use rechargeable batteries. • Do not use alkaline and manganese batteries together. • The monitor is po
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        SETTING THE CLOCK 1  Initial state. (When you load the batteries in the unit for the fi rst time,  carry out the reset procedure.) * Date/hour/alarm setting when the batteries are fi rst loaded  into the unit. Data and time: 12:00 am, January 1, 2007 Alarm: 12:00 am, alarm is in OFF state 2  Date and time correcting procedure  The alarm time, current time and calendar should be set in the written order. • Each time you press the “MODE” switch, the data item to be modifi ed changes in the  sequence 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        English SETTING THE CLOCK 3  Correcting the “minute” of an alarm time • Press “MODE” switch for one second or more to place the  unit in the alarm-time minute correction state.  • Press “SET” switch to increase the minute of the alarm time  in increments of one minute. 4  Correcting the “hour” of an alarm time • After the completion of the alarm-time minute correction as  described above, press “MODE” switch to place the unit in  the alarm-time hour correction state. • Press “SET” switch to incr
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        SETTING THE CLOCK 7  Correcting the “hour” of the current time • After the completion of the current-time minute correction as  described above, press “MODE” switch to place the unit in  the current-time hour correction state. • Press “SET” switch to increase the hour of the current time in  increments of one hour. 8  Correcting the “year” • After the completion of the current-time hour correction as  described above, press “MODE” switch to place the unit in  the year correction state. • Press “
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        English SETTING THE CLOCK 11   Changeover of the “time system” • After the completion of the day-of-the-month correction as  described above, press “MODE” switch to place the unit in  the time system selection state.  • Every time “SET” switch is pressed, the 12-hour system  (12H) and (24H) will be changed over.  • Press “MODE” switch after activating the time system  indication on the display to revert the display to the time  indication. This completes the clock setting procedure. 12   How to 
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        MEASURING YOUR BLOOD PRESSURE 1 ATTACHING THE ARM CUFF Release lever 1 Press the release lever on the cuff to  open the cuff. 2  Slip the arm cuff through your arm so that  the blue marker comes to the palm side. 3 Adjust the position of the arm cuff so that the blue marker is located in  the center of your arm and the hem of the cuff is 1 to 2 cm above your  elbow. Blue marker * The cuff should be put on the bare arm or over a light-weight underwear. * If you wear a heavy-weight top, please rem
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        English MEASURING YOUR BLOOD PRESSURE Turning the knob  4 Turn the knob clockwise until it  clockwise tightens  idles. the cuff. Turning it  to the left will have  no effect. 5  Place your arm on a table or the like so that the center of the cuff  comes to the height of your heart. 6  Relax your arm and lightly open the palm upward. ■ To loosen the cuff just press the release lever marked “PUSH”. If the release lever does not work, you can  still release the cuff by pressing on the tab in  the h
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        TIPS FOR OBTAINING ACCURATE MEASUREMENTS Your blood pressure varies according to your posture, the time of day and a range of other  factors. Ideally, you should measure your blood pressure in the same posture at the same  time every day. ■ Taking measurements while sitting 1 Place your arm on a table or similar surface with  your forearm extended. 2 It is important to have the arm cuff level with  your heart. 3 Open your hand slightly on the table so that your  palm is facing up and your fi nger
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        English MEASURING YOUR BLOOD PRESSURE 2 Plug the air hose connector into  the main unit. • Plug the air hose connector fi rmly into  the air hose socket on the main unit as  illustrated. Air hose socket 3 Start measurement. • Press the "START/STOP" switch. • All of the segment will be displayed. • The  mark comes on. • The  mark goes out. Now, the pump activates. - Eng 20 -