Electric Dryer Installation Instructions
Table of Contents
DRYER SAFETY ......................................................................... 2
INSTALLATION REQUIREMENTS ............................................. 3
Tools and Parts ...................................................................... 3
LOCATION REQUIREMENTS .................................................... 4
ELECTRICAL REQUIREMENTS ................................................ 5
INSTALL LEVELING LEGS ............
Resumo do conteúdo contido na página número 2
DRYER SAFETY 2
Resumo do conteúdo contido na página número 3
INSTALLATION REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed: Parts supplied (all models): Leveling legs (4) for models Leveling legs (4) for models Flat-blade screwdriver #2 Phillips screwdriver with riser without riser Parts supplied (steam models): Adjustable wrench that Level opens to 1" (25 mm) or hex-head socket wrench “Y” connector Short inlet hose Wire
Resumo do conteúdo contido na página número 4
INSTALLATION CLEARANCES LOCATION REQUIREMENTS Location must be large enough to allow dryer door to open fully. DRYER DIMENSIONS Models with riser Back view Side view Models without riser You will need: ■ A location allowing for proper exhaust installation. See “Venting Requirements.” ■ A separate 30 amp circuit. ■ If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.” ■ Floor must support dryer weight of
Resumo do conteúdo contido na página número 5
Spacing for recessed area or closet installation ELECTRICAL REQUIREMENTS All dimensions show recommended spacing allowed, with tested It is your responsibility: spacing of 0" (0 mm) clearance on sides and rear. ■ To contact a qualified electrical installer. ■ Additional spacing should be considered for ease of ■ To be sure that the electrical connection is adequate and in installation and servicing. conformance with the National Electrical Code, ANSI/NFPA 70 ■ Additional clearances might be
Resumo do conteúdo contido na página número 6
If your outlet looks like this: INSTALL LEVELING LEGS Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30 R. The ground wire (ground 4-wire conductor) may be either green or bare. The receptacle neutral conductor must be identified by a (14-30R) white cover. If your outlet looks like this: Pre
Resumo do conteúdo contido na página número 7
ELECTRICAL CONNECTION 2. Remove terminal block cover Power Supply Cord B E C A D F Before you start, disconnect power. Remove hold-down screw (D) and terminal block cover (A). A. Terminal block cover B. External ground conductor screw C. Center terminal block screw D. Hold-down screw E. Neutral ground wire F. Hole below terminal block cover POWER SUPPLY CORD CONNECTION Power Supply Cord Strain Relief Attach power supply cord 1. strain relief Electrical Connection Options A 1. Cho
Resumo do conteúdo contido na página número 8
If your outlet looks like this: 2. Connect neutral ground wire Power supply cord 4-wire receptacle and neutral wire (NEMA Type 14-30R): Go to “4-Wire Power Supply Cord Connection” on this page. E Power supply cord 3-wire receptacle B (NEMA Type 10-30R): Go to “3-Wire Power Supply Cord C Connection” on page 9. 4-wire Power Supply Cord Connection IMPORTANT: A 4-wire connection is required for mobile homes and Connect neutral ground wire (E) and neutral wire (white) (C) where local codes do
Resumo do conteúdo contido na página número 9
3-wire Power Supply Cord Connection 3. Connect remaining wires Use where local codes permit connecting cabinet-ground conductor to neutral wire. 3-wire receptacle (NEMA 3-prong plug type 10-30R) Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requirements.” DIRECT WIRE CONNECTION Spade terminals with Ring terminals upturned ends 1. Remo
Resumo do conteúdo contido na página número 10
5" (127 mm) 2. Prepare to connect neutral 2. Attach direct wire cable ground wire and neutral wire to strain relief E A B Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A). If your wiring looks like this: 4-
Resumo do conteúdo contido na página número 11
3½" (89 mm) 5. Connect remaining wires 3. Connect neutral wire B C Place hooked end of neutral wire (white Place hooked ends of remaining direct wire cable wires or center) (C) of direct wire cable under under outer terminal block screws (hooks facing right). center terminal block screw (B). Squeeze Squeeze hooked ends together and tighten screws. Finally, hooked end together. Tighten screw. reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down
Resumo do conteúdo contido na página número 12
VENTING 2. Connect neutral ground wire and neutral wire VENTING REQUIREMENTS B E C Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw. 3. Connect remaining wires WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspa
Resumo do conteúdo contido na página número 13
Exhaust hoods: PLAN VENT SYSTEM ■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or Recommended exhaust installations snow). Typical installations vent the dryer from the rear of the dryer. Other installations are possible. Recommended Styles: B C D E A F Louvered Hood Box Hood G Acceptable Style: B H A. Dryer E. Clamps B. Elbow F. Rigid metal or flexible metal vent C. Wall G. Vent length necessary to connect elbows D. Exhau
Resumo do conteúdo contido na página número 14
If you prefer, dryer may be converted to exhaust through Special provisions for mobile homes: the bottom. You must contact your local dealer to have Exhaust vent must be securely fastened to a noncombustible dryer converted. portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside. B A A. Standard rear offset exhaust installation B. Bottom exhaust installation Moblie Home Exhaust installation Alternate installations for close clearances Ven
Resumo do conteúdo contido na página número 15
CONNECT INLET HOSES Maytag Vent System Chart For non-steam models, skip to “Connect Vent.” The dryer must be connected to the cold water faucet using Number of Type Box/louvered Angled 90° elbows of vent hoods hoods the new inlet hoses. Do not use old hoses. Turn cold water off, remove and 0 Rigid metal 94 ft. (28.7 m) 100 ft. (30.5 m) 1. replace rubber washer 1 Rigid metal 90 ft. (27.4 m) 84 ft. (25.6 m) 2 Rigid metal 80 ft. (24.4 m) 74 ft. (22.6 m) 3 Rigid metal 71 ft. (21.6 m) 65 f
Resumo do conteúdo contido na página número 16
Attach long hose to “Y” Turn on cold water faucet 4. 6. connector and tighten couplings Check that the water faucets are turned on. One end of the long hose has a wire mesh strainer inside the coupling. Attach this end to the “Y” connector. Attach washer 7. Check for leaks cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupl
Resumo do conteúdo contido na página número 17
CONNECT VENT LEVEL DRYER Level Dryer 1. Connect vent to exhaust outlet 1. Place level here Place level here Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp. Check levelness of dryer from side to side. Repeat from front to back. 2. Move dryer to final location NOTE: The dry
Resumo do conteúdo contido na página número 18
COMPLETE INSTALLATION REVERSE DOOR SWING CHECKLIST You can change your door swing from a right-side opening to a left-side opening, if desired. Check that all parts are now installed. If there is an extra q 1. Place a towel or soft cloth on top of dryer or work space to part, go back through steps to see what was skipped. avoid damaging the surface. Check that you have all of your tools. q Remove the door assembly Dispose of/recycle all packaging materials. q 1. Open the dryer door. Che
Resumo do conteúdo contido na página número 19
4. Install the two hinges to the front panel of the dryer using Reverse the strike 4 screws. Use the non-slotted side to attach the hinge 1. Remove the door strike from the dryer door opening. to the front panel. 2. Remove the cosmetic screw opposite the door strike. 5. Install scr ews in top hinge holes in the door. Do not tighten screws. Leave approximately 1/4" (5 mm) of screw exposed. B A A. Door strike B. Cosmetic screw 3. Reinstall the door strike and cosmetic scr e
Resumo do conteúdo contido na página número 20