Resumo do conteúdo contido na página número 1 
                    
                        Gas Dryer Installation Instructions 
Canadian Electric Dryer Installation Instructions 
Instructions pour l’installation de la sécheuse à gaz  
(É.-U. et Canada) et électrique (Canada uniquement) 
Table of Contents Table des matières
DRYER SAFETY ............................................................... 2 SÉCURITÉ DE LA SÉCHEUSE ........................................18
INSTALLATION REQUIREMENTS ................................... 4 EXIGENCES D’INSTALLATION ...............................
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2                                                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        3                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        INSTALLATION REQUIREMENTS Tools needed for gas installations: TOOLS AND PARTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed  here. Tools needed for all installations: 8" (203 mm) or 10"  8" (203 mm) or 10"   (254 mm) pipe wrench (254 mm) adjustable wrench   (for gas connections) Flat-blade screwdriver Adjustable wrench that  opens to 1" (25 mm)  or hex-head socket wrench  Pipe-joint compound   resistant to LP gas
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        INSTALLATION CLEARANCES LOCATION REQUIREMENTS The location must be large enough to allow the dryer door   to open fully. DRYER DIMENSIONS Side view with open door dimensions: You will need: ■ A location allowing for proper exhaust installation.   Back view: See “Venting Requirements.” ■ A separate 15 or 20-amp circuit needed for gas dryers and  30-amp circuit needed for electric dryers. ■ If using power supply cord, a grounded electrical outlet   located within 2 ft. (610 mm) of either side of d
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Spacing for recessed area or closet installation ELECTRIC DRYER   All dimensions show recommended spacing allowed, with tested  POWER HOOKUP- CANADA ONLY spacing of 0" (0 mm) clearance on sides and rear.  ELECTRICAL REQUIREMENTS ■ Additional spacing should be considered for ease of  installation and servicing. ■ Additional clearances might be required for wall, door, and  floor moldings. ■ Additional spacing should be considered on all sides of the  dryer to reduce noise transfer. ■ For closet i
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        GAS SUPPLY REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS ■ 120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical  supply is required. A time-delay fuse or circuit breaker is  recommended. It is also recommended that a separate  circuit serving only this dryer be provided. GAS TYPE Natural Gas: GROUNDING INSTRUCTIONS This dryer is equipped for use with Natural gas. It is design-    For a grounded, cord-connected dryer:  certified by CSA International for LP (propane or butane) 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        LP Gas Conversion: GAS SUPPLY CONNECTION REQUIREMENTS  ■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting  IMPORTANT: Conversion must be made by a qualified    between the flexible gas connector and the dryer gas pipe,   technician. as needed to avoid kinking. No attempt shall be made to convert the dryer from the gas  ®† ■ Use only pipe-joint compound. Do not use TEFLON tape. specified on the model/serial rating plate for use with a different  gas without consulting your gas company. ■ 
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        A INSTALL LEVELING LEGS MAKE GAS CONNECTION  1. Connect gas supply to dryer Flared   Non-flared   male fitting male fitting B Prepare dryer for leveling legs 1.  Remove red cap from gas pipe. Using a wrench to tighten,  connect gas supply to dryer. Use pipe-joint compound   on threads of all non-flared male fittings. If flexible metal   tubing is used, be sure there are no kinks. NOTE: For LP gas connections, you must use pipe-joint  compound resistant to action of LP gas. Do not use   ®† TEFLON
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Exhaust hoods: VENTING ■ Must be at least 12" (305 mm) from ground or any object   that may obstruct exhaust (such as flowers, rocks, bushes,   VENTING REQUIREMENTS or snow). Recommended Styles: Louvered Hood Box Hood Acceptable Style: WARNING: To reduce the risk of fire, this dryer MUST BE  EXHAUSTED OUTDOORS. Angled Hood IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent,  Elbows: chimney, wall, ceiling, attic, crawlspace, or a conceale
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        If you prefer, dryer may be converted to exhaust through   PLAN VENT SYSTEM the bottom. You must contact your local dealer to have dryer  converted. Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer.  Other installations are possible. B C D E A B A F    A. Standard rear offset exhaust installation G    B. Bottom exhaust installation B Alternate installations for close clearances Venting systems come in many varieties. Select the type best  H for yo
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Determine vent path: INSTALL VENT SYSTEM ■ Select route that will provide straightest and most direct   path outdoors. 1. Install exhaust hood ■ Plan installation to use fewest number of elbows and turns. ■ When using elbows or making turns, allow as much room   12" min. as possible. (305 mm) ■ Bend vent gradually to avoid kinking. ■ Use as few 90° turns as possible. Determine vent length and elbows needed for best  drying performance: ■ Use following Vent System Chart to determine type of vent 
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Attach short hose and   2. Attach long hose to dryer fill  5.  “Y” connector valve and tighten coupling 3 3 /4" 11" (95 mm) (279 mm) Fig. A Fig. B If space permits, attach the female end of the “Y” connector  to the cold water faucet. See figure A. Attach other end of long hose   If “Y” connector cannot be attached directly to the cold water  to fill valve at bottom of dryer   faucet, the short hose must be used. See figure B. Attach  back panel. Screw on coupling   short hose to cold water fauc
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        CONNECT VENT LEVEL DRYER 1. Level Dryer 1. Connect vent to exhaust outlet Place  level here Place  level here Using a 4" (102 mm) clamp, connect vent to exhaust outlet   in dryer. If connecting to existing vent, make sure vent is  clean. Dryer vent must fit over dryer exhaust outlet and inside  exhaust hood. Check that vent is secured to exhaust hood  with a 4" (102 mm) clamp. Check levelness of dryer from side to side. Repeat from   front to back.   2. Move dryer to final location NOTE: The dry
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        COMPLETE INSTALLATION REVERSE DOOR SWING CHECKLIST You can change your door swing from a right-side opening   to a left-side opening, if desired.  Check that all parts are now installed. If there is an extra   q part, go back through steps to see what was skipped. 1. Place a towel or soft cloth on top of dryer or work space     Check that you have all of your tools. to avoid damaging the surface. q  Dispose of/recycle all packaging materials. q Remove the door assembly  Be sure the water faucets
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Reverse the  strike 4.  Install the two hinges to the front panel of the dryer using   4 screws. Use the non-slotted side to attach the hinge   1. Remove the door strike (A) from the dryer door opening. to the front panel. 2.  Remove the cosmetic screw (B) opposite the door strike (A). 5. Install scr ews in top hinge holes in the door. Do not tighten  screws. Leave approximately 1/4" (5 mm) of screw exposed. B A               A. Door strike  B. Cosmetic screw 3.   Reinstall the door strike and c
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        DRYER RESULTS TROUBLESHOOTING Clothes are not drying satisfactorily, drying times are  DRYER OPERATION too long, or load is too hot Dryer will not run ■ Is the lint screen clogged with lint?  ■ Has a household fuse blown, or has a circuit breaker  Lint screen shold be cleaned before each load. tripped?  There may be two household fuses or circuit breakers   for the dryer. Check that both fuses are intact and tight,   or that both circuit breakers have not tripped. Replace   the fuse or reset the
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        SÉCURITÉ DE LA SÉCHEUSE IMPORTANT : Pour mettre l’ancienne sécheuse au rebut ou pour la remiser, enlever la porte. 18                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        19                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        EXIGENCES D’INSTALLATION OUTILLAGE ET PIÈCES Rassembler les outils et pièces nécessaires avant d’entreprendre  l’installation. Lire et observer les instructions fournies avec  chacun des outils de la liste ci-dessous. Outils nécessaires à toutes les installations : Composé d’étanchéité des  raccords filetés – résistant  au gaz propane Pièces fournies (tous les modèles) :  Tournevis à lame plate Clé à molette avec ouverture  jusqu’à 1" (25 mm) ou clé à  douille hexagonale  Pieds de nivellement (4