Resumo do conteúdo contido na página número 1 
                    
                        If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DEWALT � www.dewalt.com
INSTRUCTION MANUAL
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA 
GUIDE D'UTILISATION DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES 
DE USAR EL PRODUCTO. 
MANUAL DE INSTRUCCIONES
D55168
Oil Free Portable Air Compressor
Compresseur d’air portatif sans huile
Compresor de aire sin aceite portátil         
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        FIG. 1 D D55168 Air Compressor B E  A. On/Off Switch  F. Check Valve C  B. Air Tank Pressure Gauge G. Safety Valve A  C. Regulated Pressure Gauge H. Air Tank Drain Valve F I  D. Pressure Regulator I. Pressure Switch  E. Quick Connect J. Air Intake Filter G Pump/Motor Specifi cations J Voltage: Single Phase 120V Minimum branch circuit requirement: 15 A Fuse Type: Time delay Specifi cations MODEL D55168 WEIGHT 88 lbs. (39.92 kg) H HEIGHT 41.75" (1060.5 mm) WIDTH 19.0" (482.6 mm) Declared Noise Emiss
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        English  � lead from lead-based paints Defi nitions: Safety Guidelines  � crystalline silica from bricks and cement and other masonry  products The definitions below describe the level of severity  for each signal word. Please read the manual and  � arsenic and chromium from chemically-treated lumber pay attention to these symbols. Your risk from these exposures varies, depending on how often you  do this type of work. To reduce your exposure to these chemicals:  DANGER: Indicates an imminently h
                    
                    Resumo do conteúdo contido na página número 4 
                    
                         � If electrical sparks from  � If spraying flammable materi- compressor come into con- als, locate compressor at  tact with flammable vapors, least 20 feet (6.1 m) away   DANGER: RISK TO BREATHING (ASPHYXIATION)  they may ignite, causing fire from spray area. An addi- or explosion. tional length of hose may be  WHAT CAN HAPPEN HOW TO PREVENT IT required.  � The compressed air directly  � Air obtained directly from the   � Store flammable materials in  from your compressor is not compressor shou
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        English Attachments & accessories:  � Exceeding the pressure  � Follow the equipment  rating of air tools, spray guns, manufacturers  WARNING: RISK OF BURSTING air operated accessories, recommendation and never  Air Tank: The air tank on your Air Compressor is designed and may tires, and other inflatables exceed the maximum allowable  be UM coded (for units with air tanks greater than 6 inch diameter) can cause them to explode or pressure rating of attachments.  according to ASME Section VIII, D
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        WARNING: RISK OF ELECTRICAL SHOCK WARNING: RISK FROM FLYING OBJECTS WHAT CAN HAPPEN HOW TO PREVENT IT WHAT CAN HAPPEN HOW TO PREVENT IT  � The compressed air stream  � Always wear certified safety   � Your air compressor is  � Never operate the compressor  can cause soft tissue equipment: ANSI Z87.1 eye  powered by electricity. outdoors when it is raining or  damage to exposed skin and protection (CAN/CSA Z94.3)  Like any other electrically in wet conditions. can propel dirt, chips, loose with s
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        English  � Attempting to operate  � Any repairs required on this  compressor with damaged or product should be performed  missing parts or attempting by a DEWALT factory service  WARNING: RISK OF HOT SURFACES to repair compressor with center or a DEWALT authorized  protective shrouds removed service center. WHAT CAN HAPPEN HOW TO PREVENT IT can expose you to moving   � Touching exposed metal such  � Never touch any exposed  parts and can result in  as the compressor head, metal parts on compress
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        �  Equip area of operation with a  fire extinguisher.  � Do not op erate machine with   CAUTION: RISK FROM NOISE missing, broken, or un au tho- WHAT CAN HAPPEN HOW TO PREVENT IT rized parts.  � Under some conditions and  � Always wear certified safety  duration of use, noise from equipment: ANSI S12.6  this product may contribute (S3.19) hearing protection.   to hearing loss.  WARNING: RISK OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT SAVE THESE INSTRUCTIONS   � A portable compressor  � Always o
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        English DRAIN VALVE SAFETY VALVE The drain valve (H) is located at the base of the air  If the pressure switch does not shut off the air  tank and is used to drain condensation at the end  compressor at its cut-out pressure setting, the  of each use. See Draining Air Tank under  safety valve (G) will protect against high  pressure by popping out at its factory set Maintenance.  H pressure (slightly higher than the pressure  COOLING SYSTEM switch cut-out setting). G This compressor contains an ad
                    
                    Resumo do conteúdo contido na página número 10 
                    
                         2. Ensure the outlet being used has the same configuration as the  INSTALLATION grounded plug. DO NOT USE AN ADAPTER. Assembly  3. Inspect the plug and cord before each use. Do not use if there  are signs of damage. INSTALLING HOSES  4. If these grounding instructions are not completely understood, or  WARNING: Risk of unsafe operation. Firmly grasp hose in hand  if in doubt as to whether the compressor is properly grounded,  when installing or disconnecting to prevent hose whip. have the insta
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        English Do not place rags or other containers on or near these openings. Voltage and Circuit Protection Place the air compressor on a flat surface resting on the rubber  Refer to the Voltage and Minimum Branch Circuit Requirements  feet and wheels. under Pump/Motor Specifications. CAUTION: Certain air compressors can be operated on a ELECTRICAL 15 amp circuit if the following conditions are met.  Refer to all safety instructions before using unit. Observe extension  � Voltage supply to circuit m
                    
                    Resumo do conteúdo contido na página número 12 
                    
                         2. When location is reached slowly lower compressor to ground.  BREAK-IN PROCEDURE Always store compressor in a vertical position resting on  WARNING: Risk of property damage. Serious damage may result if  the rubber bumpers and wheels. the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into  PREPARATION FOR USE service for the first time and when the check valve or a compressor  Pre-Start Checklist (Fig. 1) pump/motor has b
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        English CAUTION: Risk of unsafe operation. Compressed air from the   2. Remove air compressor plug from outlet. unit may contain water condensation and oil mist.  Do not spray un fil-  3. Drain air tank. tered air at an item that could be damaged by moisture. Some air   4. Allow air compressor to cool down before starting service. op erated tools or de vic  es may require filtered air. Read the in struc- NOTE: All compressed air systems contain maintenance parts (e.g.,  tions for the air tool or
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        CAUTION: Risk of property damage. Drain water from air tank may  Checking Safety Valve contain oil and rust, which can cause stains.  WARNING: Risk of bursting. If the safety valve does not work   5. When air tank pressure gauge reads 10 PSI, rotate valve to the  properly, over-pressurization may occur, causing air tank rupture or  fully open position. an explosion.  6. Close drain valve when finished. WARNING: Risk from flying objects. Always wear certified safety  equipment: ANSI Z87.1 eye pro
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        English specific warranty information contained either in the packaging, call  SERVICE INFORMATION the local company or see website for warranty information. Please have the following information available for all service calls: FREE WARNING LABEL REPLACEMENT: If your warning labels  Model Number ____________ Serial Number _________________ become illegible or are missing, call 1-800-4-DEWALT for a free  Date and Place of Purchase ______________________________ replacement. Repairs To assure pro
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        GLOSSARY CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSI: Pounds per square inch; a unit of measure of pressure. kPa (kilopascal): Metric pressure measurement. 1 kilopascal equal 1000 pascals. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified  independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety. Cut-In Press
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        English Troubleshooting Guide This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance  personnel can perform some corrective actions, and others may require the assistance of a qualified DEWALT technician or your dealer. Problem Code Excessive air tank pressure-safety valve pops off  ......................................................................1, 2 Air leaks  ..........................................
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        CODE POSSIBLE CAUSE POSSIBLE SOLUTION 4 Defective air tank Air tank must be replaced. Do not repair the leak. WARNING: Risk of bursting. Do not drill into, weld or other- wise modify air tank or it will weaken. The air tank can rupture or  explode. 5 Leaking seals Contact a DEWALT factory service center or a DEWALT authorized  service center. 6 Defective safety valve Operate safety valve manually by pulling on ring. If valve still leaks,  it must be replaced. 7 Regulator is not adjusted correctl
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        English CODE POSSIBLE CAUSE POSSIBLE SOLUTION 15 Tank pressure exceeds pressure switch cut-in Motor will start automatically when tank pressure drops below cut- pressure in pressure of pressure switch. 16 Extension cord is wrong length or gauge Check for proper gauge wire and cord length refer to the Extension  Cords under Installation. 17 Loose electrical connections Check wiring connection inside pressure switch and terminal box  area. 18 Possible defective motor Contact a DEWALT factory servi
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        FIG. 1 D Compresseur d’air, modèle D55168 B  A.  Interrupteur Marche/Arrêt G. Soupape de sûreté E C  B.  Manomètre du réservoir d’air H. Soupape de purge du  réservoir d’air  C.  Manomètre régulé A  I. Rembobineur de cordon   D.  Régulateur de pression F I d’alimentation  E.  Branchements rapides G  J. Filtre d’admission d’air  F.  Clapet J Fiche technique de la pompe/du moteur Tension : monophasé, 120V Exigence minimale du circuit de dérivation : 15 A Type de fusible : temporisation Fiche techn