Resumo do conteúdo contido na página número 1 
                    
                        C
N
E
R
G
T
I
Bay Window 
Rear/Top Convertible 
Direct Vent Fireplaces 
Model: DVRTSB
   
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE
WARNING! 
IF THE INFORMATION IN THIS 
MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT, CAUSING 
PROPERTY DAMAGE, PERSONAL 
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be 
performed by a qualified installer, 
Homeowner’s Installation and 
service agency or your gas s
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        DVRTSB Bay Window Fireplace Table of Contents Thank you & congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these  instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions  Important Curing/Burning Instructions ...................................
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        DVRTSB Bay Window Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified  11. When fireplace is installed directly on carpeting, vinyl  installer in accordance with local building codes  tile or any combustible material other than wood,  and with current CSA-B149.1 Installation codes for  this fireplace must be installed on a metal or wood  Gas Burning Appliances and Equipment. For U.S.A  panel extending the full width and depth of the  Installations f
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        DVRTSB Bay Window Fireplace Fireplace Dimensions (Installed as Top Vent) G G F F E Gas  Line  EB1 Box Inlet Inlet 2 ³⁄₈" 4 ¹⁄₈" (60mm) K - Rough Opening Depth (105mm) M - Rough Opening Width 3 ⁷⁄₈" 5 ⁷⁄₁₆" (99mm) (138mm) Rough H Opening I Height J L A B 7/8" Dia. 1 ¹⁄₂" Dia. C D 3848 Fig. 2  Fireplace specifications and framing dimensions.  Ref. DVRTSB (Top Vent) 3848   A 35” (888 mm) DVRTSB  B 34 ³⁄₈” (873 mm) top vent   C 32 ³⁄₄” (831 mm) specs  D 34 ⁷⁄₈”  (885 mm) 7/03  E 2 ¹⁄₄” (56 mm)  F 2” 
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        DVRTSB Bay Window Fireplace Fireplace Dimensions (Installed as Rear Vent) G G F F E Gas  Line  EB1 Box  Inlet Inlet 2³⁄₈" 4¹⁄₈" (60mm) K - Rough Opening Depth (105mm) M  - Rough Opening Width 3 ⁷⁄₈" 5 ⁷⁄₁₆" (99mm) (138mm) Rough H J Opening Height I L A B 7/8" Dia. 1 ¹⁄₂" Dia. C D 3848 Fig. 3  Fireplace specifications and framing dimensions. 3848   Ref. DVRTSB (Rear Vent)  A 35” (888 mm) DVRTSB  B 34 ³⁄₈” (873 mm) rear vent   C 32 ³⁄₄” (831 mm) specs  D 34 ⁷⁄₈”  (885 mm) 7/03  E 2 ¹⁄₄” (56 mm)  F 
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        DVRTSB Bay Window Fireplace V Locating Your Fireplace W X Y X Z X X A A B C D E Y Fireplace Y Z A Y Top Louvre  Assembly FP1374 Top of  Fig. 1  Locating gas fireplace. Combustion  A. Wall Location (Fig. 1) Chamber  Y (Minimum distance between a glass panel and a parallel  Bottom of Door  CFM146 Trim wall = 3’ (914 mm) Mantel Chart  Z (Minimum distance between  edge of a glass panel and  CFM146 an adjacent wall = 2-3/4” (70 mm)  Mantel Shelf DV Mantel Chart Mantel from Top 7/5/01   sta B. Island L
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        DVRTSB Bay Window Fireplace ance when finishing walls above sides of the appli- Gas Line Installation ance with glass windows. Attach the wall finishing to  the constructed frame not the appliance. When purging the gas lines, the front glass  5. On DVRTSB models, drywall, wood or wood molding  must be removed. may be placed with zero clearance to the  rear  The gas pipeline can be brought in through the side and  wall of the unit, along the vertical edge formed   back of the fireplace as well as th
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        DVRTSB Bay Window Fireplace EB-1 Electrical Box Remote ON/OFF Switch Installation The fireplace, when installed, must be elec- 1.  Thread the wiring through the holes on the end   trically connected and grounded in accord- panels of the appliance. Take care not to cut the wire  ance with local codes or, in the absence or insulation on metal edges. Route the wire to   of local codes, with the current CSA C22.1 a conveniently located receptacle box. Canadian Electrical Code 2. Attach the wire to th
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        DVRTSB Bay Window Fireplace Optional Top Vent Application This appliance is shipped as a rear vent unit. If the  Insulation installation layout requires the unit to be a top vent con- figuration the appliance can be converted by following  the steps below. Flue  Cover When removing and refitting the plates and adapter be  Flue  sure the associated gaskets are undamaged and refitted  Pipe as required. Remove  1.   Remove the 10 screws securing the outer collar  Screws (4) adapter to the fireplace bod
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        DVRTSB Bay Window Fireplace General Venting Information – Termination Location den sheds, fences, decks or utility buildings within 24”  Your fireplace is approved to be vented either through  from the front of the termination hood. the rear wall or the vertical side wall, or vertical through  the roof. Location of Vent Termination  • Only venting components specifically approved and It is imperative the vent termination be located observ- labeled for this fireplace may be used. ing the minimum cle
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        V Operable DVRTSB Bay Window Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E L C B ����� B V B V ������ V Fixed Operable Closed F V B M V B J X B I V K X A CFM145a AREA WHERE TERMINAL IS NOT PERMITTED V VENT TERMINATION X AIR SUPPLY INLET 1 2   Canadian Installations US Installations CFM145a  A = Clearance above grade, veranda, porch,  12” (30cm) DV Termin Location 12” (30cm) 5/01/01 Rev. 12/05/01    deck, or balcony sta  B = Clearance to window 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        DVRTSB Bay Window Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.  Inside Corner Alcove Applications* Outside Corner D C C F = Combustible  G =   6" (152 mm) Combustible   V G   6" (152 mm) Noncombustible  V E   2" (51 mm) Noncombustible  O V F   2" (51 mm) Balcony - Balcony -  with no side wall with perpendicular side wall E = Min. 6” (152 mm) for  non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Vertical dimension from the floor of the unit To the center of the horizontal vent pipe DVRTSB Bay Window Fireplace How to Use the Vent Graph Rear Wall Vent Applications The vent chart should be read in conjunction with the  When installed as a rear vent unit this appliance may  following vent installation instructions to determine the  be vented directly to a termination located on the rear  relationship of the vertical and horizontal dimensions of  wall behind the appliance. the vent system. • 
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        DVRTSB Bay Window Fireplace STEP 5 Vent Opening for Combustible Wall Guide the vent through the vent hole as you place the  9 ³⁄₈” appliance in its installed position. Guide the 4” (102mm)  (240 mm) and 7” (175 mm) collars of the vent termination into the  outer ends of the venting. Do not force the termination.  If the vent pipes do not align with the temination remove  10 ³⁄₈” and realign the venting at the appliance flue collars.  (265 mm) Attach the termination to the wall as outlined in the 
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        DVRTSB Bay Window Fireplace • The maximum number of 90° elbows per side wall  Example: In Fig. 22 installation is three (3).   Elbow 1 = 90°  Elbow 2 = 45° • If a 90° elbow is fitted directly on top of the fireplace   Elbow 3 = 45° flange, the maximum horizontal vent run before the   Elbow 4 = 90° termination or a vertical rise is 36” (914 mm).  Total Angular Variation = 270° Max. 36" o 1 + 2 + 3 + 4 = 270 (914mm) Max. 20" (508mm) 1 1 2 2 3 3 4 4 FP1381 Fig. 20  Maximum horizontal vent run. FP1383 
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        DVRTSB Bay Window Fireplace STEP 2 STEP 5 Measure wall thickness and cut zero clearance sleeve Measure the horizontal length requirement including a  parts to proper length (MAXIMUM 12”/305 mm). As- 2” (51 mm) overlap, i.e. from the elbow to the outside  semble sleeve and attach to firestop with #8 sheet wall face plus 2” (51 mm) (or the distance required if  metal screws (supplied). Install firestop assembly. (Fig. installing a second 90° elbow. (Fig. 26) 24) Always install horizontal venting on 
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        DVRTSB Bay Window Fireplace Do not back fill around snorkel. Below Grade Installation A clearance of at least 4” (100mm) must  When it is not possible to meet the required vent ter- be maintained between the snorkel and the  minal clearances of 12” (305 mm) above grade level a soil. starter kit is recommended. It allows installation depth  If the foundation  of down to 7” (178 mm) below grade level.  The 7”  is recessed, use  (178mm) is measured from the center of the horizontal  recess brackets 
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        DVRTSB Bay Window Fireplace   Min. Max. Height 40' (12.2m) 2' (610 mm) Min. Height 8' (2.4m) Max. 10' (3m) FP1389 Support straps  Fig. 31  Minimum termination to roof clearance. every 36" (914mm) Vertical Through-The-Roof Installation 1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling  Max. 10' (3m) above and mark position. Max.  Height 40' (12.2m) 3. Cut opening equal to 9 ³⁄₈” x 9 ³⁄₈” (240 x 240 mm). 4. Proceed to plumb for additional openings through  Min.  Heigh
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        DVRTSB Bay Window Fireplace Attic Insulation  Shield 3 #5 Sheet Metal  Screws per Joint Storm Collar Upper Floor Sealant 11” 11” (279mm) (279mm) TWL101a Fig. 33  Roof flashing. Joist If there is a room above ceiling level,  TWL101a Twist Lock Pipe firestop spacer must be installed on both  Firestop Spacer 2/8/99   djt the bottom and the top side of the ceiling  joists. (Fig. 34) If an attic is above ceiling  Nails (4) FP1029 level a 7DVAIS (Attic Insulation Shield)  must be installed. Fig. 34  Att
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        DVRTSB Bay Window Fireplace Twist Lock Venting Components   Starter Kit-Model 7TDVSK-Sidewall/Rearwall Venting  Starter Kit-Model 7TDVSKV-Vertical Venting   for 7TDVSKV-A order 1/12 to 6/12 roof pitch       for 7TDVSKV-B order 7/12 to 12/12 roof pitch   for 7TDSKV-F order flat roof  Starter Kit-Model 7TDVSKS-Snorkel Kit   for Below Grade Installation    45˚ Elbow   7TDV45 for Rear Vent to Vertical Vent   or Vertical/Horizontal Offsets 584B    Vent components   90˚ Transition Elbow Starter Kit