Resumo do conteúdo contido na página número 1 
                    
                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
TIARA PETITE B
DIRECT VENT ROOM HEATER 
Model: 
Tested and Portland
O-T O-T L
Oregon USA
Listed by
C US
TIARAP-BK
OMNI-Test Laboratories, Inc.
TIARAP-BR
TIARAP-CES
TIARAP-CTO
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and 
• Important operating and • Leave this manual with 
follow these instructions 
maintenance instructions party responsible for use 
included. for safe installation and 
and operation.
operation.
WARNING
     WA
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Read this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance - an This Owner's Manual should be retained for future reference.  elegant and clean alternative to wood burning appliances.  We suggest that you keep it with your other important  The Heat & Glo gas appliance you have selected is designed documents and product manuals. to provide the utmost in safety, reli
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        - TABLE OF CONTENTS - Section 7: Electrical Information Section 1: Listing and Code Approvals  A. Recommendation for Wire ..................29  A. Appliance Certifi cations ......................4  B. Connecting to the Appliance ...............29  B. Glass Specifi cations ............................4  C. Standing Pilot Ignition System   C. Specifi cations ......................................4    Wiring ..................................................29  D. High Altitude Installations .........
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        Listing and Code Approvals 1 C.  Specifi cations A.  Appliance Certifi cation Maxi- Mini- Orifi ce *Steady  **P.4 MODEL Tiara Petite B  Model mum mum Size State  % (US or Canada) Input Input (DMS) Effi ciency  LABORATORY OMNI-Test Laboratories, Inc. BTU BTU % 061-S-47b-5 Tiara Petite B (NG) 17,000 12,000 49 73.93 57.30 TYPE Vented Gas Fireplace Heater Tiara Petite B (LP) 17,000 13,000 56 78.19 63.22 STANDARD ANSI Z21.88b-2003 ּ CSA 2.33b-2003 ּ  *Maximum Vent Blower On UL307b ּ CAN/CBA 2.17-M91 **Ca
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        Inspection NOTE: The following requirements reference various  The state or local gas inspector of the side wall horizontally  Massachusetts and national codes not contained in this  vented gas fueled equipment shall not approve the installa- document. tion unless, upon inspection, the inspector observes carbon  monoxide detectors and signage installed in accordance with  G.  Requirements for the Commonwealth of      the provisions of 248 CMR 5.08(2)(a) 1 through 4.       Massachusetts Exemption
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        Getting Started 2 C. Inspect Appliance & Components A.  Design & Installation Considerations Heat & Glo direct vent gas appliances are designed to oper- ate with all combustion air drawn from outside of the building  WARNING and all exhaust gases expelled to the outside. No additional  air source is required. Inspect appliance and components for  damage. Damaged parts may impair safe  operation. • Do NOT install damaged components. CAUTION • Do NOT install incomplete components. Check building c
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        Appliance Location and Clearances 3 NOTE:  WARNING ·  Illustrations refl ect typical installations and are FOR  Fire Risk  DESIGN PURPOSES ONLY. Provide adequate clearance: ·    Illustrations/diagrams are not drawn to scale. • Around air openings • To combustibles ·   Actual installation may vary due to individual design    • For service access  preference. Locate appliance away from traffi c areas. A. Selecting Appliance Location WARNING When selecting a location for your appliance it is importan
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Termination Locations 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. VERTICAL Fire Risk. MIN. WALL Explosion Risk. LOWEST  DISCHARGE  Maintain vent clearance to combustibles OPENING as specifi ed. GAS DIRECT VENT  TERMINATION CAP • Do not pack air space with insulation or  other materials. X 12 Failure to keep insulation or other materials  away from vent pipe may cause fi re. ROOF PITCH IS  X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OP
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        M N P R G v A H D Q (See Note 2) E v V B L U.S. B T v (3 FT) v B B v S S Electrical V V Service F v v M I D* v X A J or K V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED V K = 3 ft. (U.S.A.) A = 12 inches ............. clearances above grade, veran- 6 ft. (Canada) ......... clearance to a mechanical (See Note 1) da, porch, deck or balcony (powered) air supply inlet B = 12 inches ............ clearances to window or door L** = 7 ft. ......................... clearanc
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Vent Information 5 A. Venting Components B. Use of Elbows In order to comply with applicable codes and product  warranties, use only  following venting components: CAUTION •  Hearth & Home Technologies (HHT)  ALL vent confi guration specifi cations MUST be followed. •  Simpson Dura-Vent • This product is tested and listed to these  specifi cations. •  Selkirk Direct-Temp  • Appliance performance will suffer if specifi cations are  •  Amerivent Direct not  followed. •  Security Secure Vent Diagonal r
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        D. How to Use the Vent Graph E. Venting Guidelines 1. Measure the distance from the top of appliance to the Notes:    center of the 90° elbow. On the graph below, draw a • The maximum horizontal vent run is 15 ft. (5m) when the  horizontal line from that measurement on the vertical vertical vent rise is 10 ft. (3m). axis across until it intersects with the slanted line. • Horizontal sections require a 1/4 in. (6mm) rise for every  2. From the point of this intersection, draw a vertical line to  
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        F.  Horizontal Termination WARNING Fire Hazard. Type A - Up & Out Installation Exhaust Fume Risk. TERMINATION CAP Impaired Performance of Appliance. 90° ELBOW • Ensure vent components are locked together correctly. CENTER LINE • Pipe may separate if not properly joined.  PIPE LENGTH WALL THIMBLE Step 2.   WALL THIMBLE COVER Direct vent pipe is designed with a locking connection. To  connect the venting system to the appliance flue outlet, a  PIPE LENGTH twist-lock adapter is built into the appli
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        Step 3. Step 4.  For installations using a round support box/wall thimble Position the horizontal termination cap in the center of the 10  (check pipe manufacturer's instructions), mark the wall for a in. x 10 in. (254mm x 254mm) square hole and run a bead  10 in. x 10 in.  (254mm x 254mm) square hole.  The center of non-hardening mastic around its outside edges, so as to  of the square hole should line up with the center line of the make a seal between it and the wall, attach termination cap  h
                    
                    Resumo do conteúdo contido na página número 14 
                    
                          (NOTE:  Some termination caps may cause the vent Note: The attachment from the vent pipe to the vent  pipe to be off center on flashing).  Ensure that proper termination cap must be sealed with silicone.  Termination  clearances to combustible materials are maintained.  caps shall not be recessed into a wall or siding. If you are not using an approved termination cap with  a built-in standoff on a building with vinyl siding, a  vinyl siding standoff should be installed between the  WARNING ter
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        G.  Vertical Termination 1. Direct Vent Pipe VERTICAL  TERMINATION CAP STORM  COLLAR 25 ft. (8m)  FLASHING MAXIMUM FIRESTOP SUPPORT BOX PIPE LENGTH Figure 5.11   Step 2. Set the gas appliance in its desired location. Drop a plumb  bob down from the ceiling to the position of the appliance  flue exit, and mark the location where the vent will penetrate  the ceiling. Drill a small hole at this point. Next, drop a plumb  bob from the roof to the hole previously drilled in the ceiling,  and mark the
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Step 3. To install the round support box/wall thimble cover in a flat  CAP AND STORM  ceiling, cut a 10 in. (254mm) square hole in the ceiling, Shingles overlap on COLLAR NOT SHOWN  top edge of flashing FOR CLARITY centered on the hole drilled in Step 2.  Frame the hole as  shown in Figure 5.13. Ceiling  Joists Framing Figure 5.14   Step 7.  Continue to assemble pipe sections until the height of the  1 - 1/2 in. (38mm) Long vent (before adding the termination cap) meets the minimum  Wood Screws 
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Step 9. Twist-lock the vent cap and seal. Note:  For multi-story vertical installations, a ceiling firestop  is required at the second floor, and any subsequent floors  (Figure 5.16). The opening should be framed to 10 in. x  10 in. (254mm x 254mm) inside dimensions, in the same  manner as shown in Figure 5.13 on page 16. NAILS CEILING FIRES TOP MIN. 1 in. (25mm) CLEARANCE MIN. 1 in. (25mm) CLEARANCE MIN. 1 in. (25mm) CLEARANCE MIN. 1 in. (25mm) CLEARANCE Figure 5.16 WARNING Fire Risk. Explosion
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        2. Cathedral Ceiling Step 1. Follow installation Steps 1 and 2 under vertical installation  section, page 15. Step 2. Remove shingles or other roof covering as necessary to cut  the rectangular hole for the support box. Cut the hole 1/8 in.  (3mm) larger than the support box outline. Step 3. Lower the support box through the hole in the roof until the  bottom of the support box protrudes at least 2 in. (51mm)  below the ceiling (Figure 5.17). Align the support box both  vertically and horizontal
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        3. Class A Metal Chimney Step 4. Pass the flex pipe down through the center of the chimney  system, and center the top adapter on the top of the chimney  pipe. Drill four 1/8 in. (3mm) diameter holes through the  TERMINATION CAP top adapter, and into the chimney top. Ensure that you are  TOP  drilling into the metal on the chimney. Twist lock the high  ADAPTOR  wind termination cap  onto the top adapter (Figures 5.22  FLASHING  and 5.23).  EXISTING  METAL  CHIMNEY  SYSTEM  4 in. (102mm)   FLEX P
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        4. Existing Masonry Chimney Type A & B  Co-Axial to Co-Linear CHIMNEY LINER  CHIMNEY LINER  TERMINATION  TERMINATION CAP CAP 25 ft. (8m) OF 3 in.  (76mm) FLEX  LINER EXHAUST  SECTION 3 in. (76mm)  THIS SECTION OF  CO-AXIAL TO  FLEX LINER THE CHIMNEY MUST  CO-LINEAR  BE SEALED CO-AXIAL TO  CONNECTOR CO-LINEAR  CONNECTOR THE CHIMNEY MUST BE  PIPE LENGTH SEALED FROM THE 4 ft. (1m)  PIPE LENGTH  OPTIONAL SECTION TO TERMINATION  OPTIONAL USING A SMOKE SHELF OR A  DAMPER. THE SEAL SHOULD  BE 6 in. (15