Resumo do conteúdo contido na página número 1 
                    
                        R
 
 
 
 
 
 
 
®
Intel 955X Express Chipset  
 
Thermal/Mechanical Design Guide 
®
– For the Intel 82955X Memory Controller Hub (MCH) 
 
 
April 2005 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Document Number: 307012-001                                                                                                                                                                                                                                                                                     
                    
                    Resumo do conteúdo contido na página número 2 
                    
                          R                                    ® INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY  ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN  INTEL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL  DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR  WARRANTIES RELATI
                    
                    Resumo do conteúdo contido na página número 3 
                    
                             R    Contents    1 Introduction ......................................................................................................................... 7  1.1 Definition of Terms ................................................................................................. 8  1.2 Reference Documents............................................................................................ 8  2 Packaging Technology........................................................................
                    
                    Resumo do conteúdo contido na página número 4 
                    
                          R    Figures  Figure 2-1. MCH Package Dimensions (Top View)............................................................ 9  Figure 2-2. MCH Package Dimensions (Side View)........................................................... 9  Figure 2-3. MCH Package Dimensions (Bottom View)..................................................... 10  Figure 5-1. Thermal Solution Decision Flowchart............................................................. 16  Figure 5-2. Zero Degree Angle Attach Methodolog
                    
                    Resumo do conteúdo contido na página número 5 
                    
                             R    Revision History    Revision Description Revision Date  Number  -001 • Initial Release. April 2005  §  ® Intel 955X Express Chipset Thermal/Mechanical Design Guide 5                                                                                                                                                                                                                                                                                                                                     
                    
                    Resumo do conteúdo contido na página número 6 
                    
                          R        ® 6 Intel 955X Express Chipset Thermal/Mechanical Design Guide                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Resumo do conteúdo contido na página número 7 
                    
                           Introduction  R    1 Introduction  As the complexity of computer systems increases, so do the power dissipation requirements. Care  must be taken to ensure that the additional power is properly dissipated. Typical methods to  improve heat dissipation include selective use of ducting, and/or passive heatsinks.  The goals of this document are to:  ® • Outline the thermal and mechanical operating limits and specifications for the Intel 82955X  Express Chipset Memory Controller Hub (MCH).  • Desc
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        Introduction  R    1.1 Definition of Terms    Term Description  BGA Ball grid array. A package type, defined by a resin-fiber substrate, onto which a die is  mounted, bonded and encapsulated in molding compound. The primary electrical interface is  an array of solder balls attached to the substrate opposite the die and molding compound.   BLT Bond line thickness.  Final settled thickness of the thermal interface material after installation  of heatsink.  ICH7 I/O Controller Hub. Seventh generati
                    
                    Resumo do conteúdo contido na página número 9 
                    
                           Packaging Technology  R    2 Packaging Technology  The 955X Express chipset consists of two individual components: the MCH and the ICH7. The  MCH component uses a 34 mm squared, 6-layer flip chip ball grid array (FC-BGA) package (see  ® Figure 2-1 through Figure 2-3). For information on the ICH7 package, refer to the Intel I/O  Controller Hub 7 (ICH7) Thermal Design Guidelines.   Figure 2-1. MCH Package Dimensions (Top View)  Ø5.20mm Capacitor Area, Handling Exclusion Die 19.38 Zone Keepout 1
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        Packaging Technology  R    Figure 2-3. MCH Package Dimensions (Bottom View)    NOTES:   1. All dimensions are in millimeters.  2. All dimensions and tolerances conform to ANSI Y14.5M-1994.  2.1 Package Mechanical Requirements  The MCH package has an exposed bare die that is capable of sustaining a maximum static normal  load of 10-lbf.  The package is NOT capable of sustaining a dynamic or static compressive load  applied to any edge of the bare die.  These mechanical load limits must not be exc
                    
                    Resumo do conteúdo contido na página número 11 
                    
                           Thermal Specifications  R    3 Thermal Specifications  3.1 Thermal Design Power (TDP)  Analysis indicates that real applications are unlikely to cause the chipset MCH to consume  maximum power dissipation for sustained time periods. Therefore, to arrive at a more realistic  power level for thermal design purposes, Intel characterizes power consumption based on known  platform benchmark applications. The resulting power consumption is referred to as the Thermal  Design Power (TDP). TDP is the 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        Thermal Specifications  R        ® 12 Intel 955X Express Chipset Thermal/Mechanical Design Guide                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    Resumo do conteúdo contido na página número 13 
                    
                           Thermal Simulation  R    4 Thermal Simulation  Intel provides thermal simulation models of the 955X Express chipset MCH and associated user's  guides to aid system designers in simulating, analyzing, and optimizing their thermal solutions in  an integrated, system-level environment. The models are for use with the commercially available  Computational Fluid Dynamics (CFD)-based thermal analysis tool “FLOTHERM”* (version 5.1  or higher) by Flomerics, Inc. Contact your Intel field sales represe
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        Thermal Simulation  R      ® 14 Intel 955X Express Chipset Thermal/Mechanical Design Guide                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Resumo do conteúdo contido na página número 15 
                    
                           Thermal Metrology  R    5 Thermal Metrology  The system designer must make temperature measurements to accurately determine the thermal  performance of the system. Intel has established guidelines for proper techniques to measure the  MCH die temperatures. Section 5.1 provides guidelines on how to accurately measure the MCH  die temperatures. The flowchart in Figure 5-1 offers useful guidelines for thermal performance  and evaluation.  5.1 Die Case Temperature Measurements  To ensure function
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        Thermal Metrology  R    Figure 5-1. Thermal Solution Decision Flowchart  Start Attach Run the Power thermocouples using Attach device program and recommended Tdie > to board using monitor the No metrology. Setup the Specification? normal reflow device die system in the desired process. temperature. configuration. End Heatsink Select Heatsink Yes Required Therm_Solution_Flow      Figure 5-2. Zero Degree Angle Attach Methodology       Figure 5-3. Zero Degree Angle Attach Methodology (Top View)  Di
                    
                    Resumo do conteúdo contido na página número 17 
                    
                           Reference Thermal Solution  R    6 Reference Thermal Solution  Intel has developed a reference thermal solution designed to meet the cooling needs of the MCH  under operating environments and specifications defined in this document. This chapter describes  the overall requirements for the Plastic Wave Soldering Heatsink (PWSH) reference thermal  solution including critical-to-function dimensions, operating environment, and validation criteria.  Other chipset components may or may not need att
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        Reference Thermal Solution  R    Figure 6-1. Reference Heatsink Measured Thermal Performance versus Approach Velocity    6.3 Mechanical Design Envelope  While each design may have unique mechanical volume and height restrictions or implementation  requirements, the height, width, and depth constraints typically placed on the MCH thermal  solution are shown in Figure 6-2.  When using heatsinks that extend beyond the MCH reference heatsink envelope shown in  Figure 6-2, any motherboard components 
                    
                    Resumo do conteúdo contido na página número 19 
                    
                           Reference Thermal Solution  R    Figure 6-2. Heatsink Volumetric Envelope for the MCH  Ram p Retainer Heatsink Fin Heatsink Base TIM Die FCBGA + Solder Balls Motherboard 60.6 mm 48.0 mm 26.79 mm TNB Heatsink Fin Max 2. 2 m m Component Height No component O 135 this Area 47.0 mm HS_Vol_Envelope_MCH   ® Intel 955X Express Chipset Thermal/Mechanical Design Guide 19     81.0 mm 67.0 mm 45.79 mm 60.92 mm 2.50 mm 1.90 mm 33.50 mm                                                                      
                    
                    Resumo do conteúdo contido na página número 20 
                    
                        Reference Thermal Solution  R    6.4 Board-Level Components Keep-out Dimensions  The location of hole patterns and keep-out zones for the reference thermal solution are shown in  Figure 6-3 and Figure 6-4.  Figure 6-3. MCH Heatsink Board Component Keep-out   60.6 mm 48.0 mm 26.79 mm TNB Heatsink Fin Max 2.2 mm Component Height No component O 135 this Area 47.0 mm Air Flow HS_Brd_Component_Keepout   ® 20 Intel 955X Express Chipset Thermal/Mechanical Design Guide     81.0 mm 67.0 mm 45.79 mm 60.92