Resumo do conteúdo contido na página número 1 
                    
                         
  
 
SyAM Software* Server 
Monitor Local/Central* on a 
Microsoft* Windows* 
Operating System 
 
Intel® Server Board S5000VSA with Internal 
Storage Focusing on IPMI Out of Band 
Management 
  
Recipe ID: 19SYAM190000000011-01 
                                                                                                                                                                                                                                                                             
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        SyAM Software* Comprehensive Installation Guide for Management Software  Intel® Server Board S5000VSA        Contents    Hardware Components...........................................................................................................................................................................................................3  Software Used in the Installation.........................................................................................................................
                    
                    Resumo do conteúdo contido na página número 3 
                    
                         SyAM Software* Comprehensive Installation Guide for Management Software   Intel® Server Board S5000VSA    Hardware Components   Quantity Item Manufacturer Model  1 Intel® Server Board Intel S5000VSA  1 Intel® Server Chassis  Intel SC5299-E    4 GB minimum Memory Any supported   2 Intel® Xeon® Processor Intel Any supported  2 max SATA 3.5” hard drives Any supported     Table 1 – Intel® Server Board S5000VSA Configuration Hardware     Software Used in the Installation  Dist. By Description File N
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        SyAM Software* Comprehensive Installation Guide for Management Software  Intel® Server Board S5000VSA        Introduction  This Intel® Enabled Server Acceleration Alliance (Intel® ESAA) recipe explains how to install and  configure SyAM Software* Server Monitor Local or Agent (Local installs a web browser and a  monitoring agent while installing Agent provides only a monitoring agent) on the Intel® Server Board  S5000VSA with internal storage, It also explains how to install and configure SyAM S
                    
                    Resumo do conteúdo contido na página número 5 
                    
                         SyAM Software* Comprehensive Installation Guide for Management Software   Intel® Server Board S5000VSA      System Requirements  • 200-MB disk space  • 512-MB memory  • A valid operating TCP/IP network adapter  • A x86/x64 computer running a compatible operating system  • A password set for the Administrator account on the system    Browser Requirements  • Microsoft Internet Explorer* 6+ (Service Pack 1)  • Mozilla* Firefox* (V1.0.x or above)  Installation and Configuration  Pre-Install Conside
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        SyAM Software* Comprehensive Installation Guide for Management Software  Intel® Server Board S5000VSA        4) Do not change the RMI port default value of 1099 unless this port is being used by another  application.  5) To enable security through 128-bit data encryption from the SyAM Software* server Web server  to the browser, choose the SSL option. The default is “No”.  6) After the installation has finished, the SyAM Software* services will start and dynamically  discover and configure the s
                    
                    Resumo do conteúdo contido na página número 7 
                    
                         SyAM Software* Comprehensive Installation Guide for Management Software   Intel® Server Board S5000VSA    Firewall Security  The ports listed below are automatically opened on Microsoft* Windows 2003* and Microsoft*  Windows XP* Pro systems during the installation:  • 3894: Used for Agent Management service  • 3895: Used for Central Management service  • 3930: Used for Web server service  • 5800: Used for remote console access from Central Manager  • 5900: Used for remote console access from Ce
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        SyAM Software* Comprehensive Installation Guide for Management Software  Intel® Server Board S5000VSA        1) The Baseboard Management Controller's (BMC) IP address and password using the vendor- provided utilities must be configured before the IPMI over LAN feature can be utilized.   Select the IPMI enabled system from the list of managed systems on the Central Manager* screen  and click on the “Remote Management” icon.           In the Remote Management screen (see the following figure), sel
                    
                    Resumo do conteúdo contido na página número 9 
                    
                         SyAM Software* Comprehensive Installation Guide for Management Software   Intel® Server Board S5000VSA      Figure 6 – IPMI over LAN Tab: Details Applied      Figure 7 – IPMI over LAN Tab: Connected Status  Once connected, the IPMI over LAN tab shows the status as “Connected”, depicted in figure 7, and the  following options may be performed:  • Power Off: Performs a forced power off instead of a graceful shutdown. The operating system  may or may not receive notification and shut down. This va
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        SyAM Software* Comprehensive Installation Guide for Management Software  Intel® Server Board S5000VSA        • Identify: This will light the identification LED of the system. This feature is not supported in all  hardware platforms.  • Event Log: The IPMI event log is accessed in exactly the same manner described above.  IPMI Event Log  Server Monitor* can monitor managed physical events occurring on IPMI-enabled servers. These  events are recorded in the IPMI event log, which is accessible thro
                    
                    Resumo do conteúdo contido na página número 11 
                    
                         SyAM Software* Comprehensive Installation Guide for Management Software   Intel® Server Board S5000VSA      Figure 8 – IPMI Event Log  The IPMI event log provides administrators with the option to clear or purge the log by clicking the  “Clear Log” button.   Note: This action cannot be undone.  IPMI Event Retrieval  The IPMI event log provides administrators with the option of retrieving and viewing some or all  events recorded for the server, and sorting them by type.   To retrieve the events 
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        SyAM Software* Comprehensive Installation Guide for Management Software  Intel® Server Board S5000VSA          Figure 9 – IPMI Event Log Retrieval  The ID values assigned to events are generated by the IPMI controller and are dependent on how the  system’s firmware is configured. As a result, the event ID may differ based on server platform.  Generate CSV  This button retrieves the events and saves them to a CSV file.       12                                                                      
                    
                    Resumo do conteúdo contido na página número 13 
                    
                         SyAM Software* Comprehensive Installation Guide for Management Software   Intel® Server Board S5000VSA                            www.intel.com/go/esaa    The information contained in this document is provided for informational purposes only and represents the current view of   Intel Corporation (“Intel”) and its  contributors ("Contributors") on, as of the date of publication.  Intel and the Contributors make no commitment to update the information contained in this  document, and Intel reserv