Resumo do conteúdo contido na página número 1 
                    
                        ® ® 
Intel StrongARM SA-1100 
Microprocessor
Developer’s Manual
August 1999
Order Number: 278088-004                                                                                                                                                                                                                                                                                                                                                                                                                
                    
                    Resumo do conteúdo contido na página número 2 
                    
                        Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual  property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability  whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to  fitness for a particular purpose, me
                    
                    Resumo do conteúdo contido na página número 3 
                    
                        Contents 1 Introduction......................................................................................................................1-1 1.1 Intel® StrongARM® SA-1100 Microprocessor .................................................. 1-1 1.2 Overview............................................................................................................ 1-4 1.3 Example System................................................................................................ 1-5 1.4 ARM™ Ar
                    
                    Resumo do conteúdo contido na página número 4 
                    
                        5.2.11 Registers 10 – 12 RESERVED............................................................. 5-6 5.2.12 Register 13 – Process ID Virtual Address Mapping.............................. 5-7 5.2.13 Register 14 – Debug Support (Breakpoints)......................................... 5-8 5.2.14 Register 15 – Test, Clock, and Idle Control.......................................... 5-9 6 Caches, Write Buffer, and Read Buffer...........................................................................6-1 6.
                    
                    Resumo do conteúdo contido na página número 5 
                    
                        9 System Control Module...................................................................................................9-1 9.1 General-Purpose I/O.......................................................................................... 9-1 9.1.1 GPIO Register Definitions..................................................................... 9-2 9.1.1.1 GPIO Pin-Level Register (GPLR) ............................................ 9-3 9.1.1.2 GPIO Pin Direction Register (GPDR) ....................
                    
                    Resumo do conteúdo contido na página número 6 
                    
                        9.5.3.6 Booting After Sleep Mode...................................................... 9-29 9.5.3.7 Reviving the DRAMs from Self-Refresh Mode ...................... 9-30 9.5.4 Notes on Power Supply Sequencing .................................................. 9-30 9.5.5 Assumed Behavior of an SA-1100 System in Sleep Mode................. 9-30 9.5.6 Pin Operation in Sleep Mode.............................................................. 9-32 9.5.7 Power Manager Registers ........................
                    
                    Resumo do conteúdo contido na página número 7 
                    
                        10.5.3 DRAM Access Followed by a Refresh Operation............................. 10-25 10.6 PCMCIA Overview........................................................................................ 10-26 10.6.1 32-Bit Data Bus Operation............................................................... 10-27 10.6.2  External Logic for PCMCIA Implementation ................................... 10-28 10.6.3 PCMCIA Interface Timing Diagrams and Parameters ..................... 10-31 10.7 Initialization of 
                    
                    Resumo do conteúdo contido na página número 8 
                    
                        11.7.5.1Lines Per Panel (LPP) ......................................................... 11-36 11.7.5.2Vertical Sync Pulse Width (VSW)........................................ 11-36 11.7.5.3End-of-Frame Line Clock Wait Count (EFW)....................... 11-37 11.7.5.4Beginning-of-Frame Line Clock Wait Count (BFW)............. 11-37 11.7.6 LCD Controller Control Register 3.................................................... 11-39 11.7.6.1Pixel Clock Divider (PCD)....................................
                    
                    Resumo do conteúdo contido na página número 9 
                    
                        11.8.3.1UDC Disable (UDD)............................................................. 11-64 11.8.3.2 UDC Active (UDA) .............................................................. 11-64 11.8.3.3Bit 2 Reserved ..................................................................... 11-64 11.8.3.4Endpoint 0 Interrupt Mask (EIM).......................................... 11-64 11.8.3.5Receive  Interrupt Mask (RIM)............................................. 11-64 11.8.3.6Transmit  Interrupt Mask (TI
                    
                    Resumo do conteúdo contido na página número 10 
                    
                        11.9.1.5Data Field ............................................................................ 11-81 11.9.1.6CRC Field ............................................................................ 11-81 11.9.1.7Baud Rate Generation......................................................... 11-81 11.9.1.8Receive Operation............................................................... 11-82 11.9.1.9Transmit Operation.............................................................. 11-83 11.9.1.10Simult
                    
                    Resumo do conteúdo contido na página número 11 
                    
                        11.9.9.5Receive Transition Detect Status (RTD)  (read/write, noninterruptible)................................................ 11-99 11.9.9.6End of Frame Flag (EOF)  (read-only, noninterruptible)................................................. 11-99 11.9.9.7CRC Error Status (CRE)  (read-only, noninterruptible)............................................... 11-100 11.9.9.8Receiver Overrun Status (ROR) (read-only, noninterruptible)............................................... 11-100 11.9.10 UAR
                    
                    Resumo do conteúdo contido na página número 12 
                    
                        11.10.10.4Transmit FIFO Service Request Flag (TFS)  (read-only, maskable interrupt).......................................... 11-122 11.10.10.5Receive FIFO Service Request Flag (RFS) (read-only, maskable interrupt).......................................... 11-122 11.10.10.6Framing Error Status (FRE)  (read/write, nonmaskable interrupt)................................... 11-123 11.10.11HSSP Status Register 1 ................................................................ 11-124 11.10.11.1Receive
                    
                    Resumo do conteúdo contido na página número 13 
                    
                        11.11.7.2Receive FIFO Service Request Flag (RFS)  (read-only, maskable interrupt).......................................... 11-139 11.11.7.3Receiver Idle Status (RID)  (read/write, maskable interrupt) ......................................... 11-140 11.11.7.4Receiver Begin of Break Status (RBB) (read/write, nonmaskable interrupt) ................................... 11-140 11.11.7.5Receiver End of Break Status (REB)  (read/write, nonmaskable interrupt)11-140 11.11.7.6Error in FIFO Flag (EIF) (rea
                    
                    Resumo do conteúdo contido na página número 14 
                    
                        11.12.6.1Audio Transmit FIFO Service Request Flag (ATS)  (read-only, maskable interrupt).......................................... 11-163 11.12.6.2Audio Receive FIFO Service Request Flag (ARS) (read-only, maskable interrupt).......................................... 11-163 11.12.6.3Telecom Transmit FIFO Service Request Flag (TTS)  (read-only, maskable interrupt).......................................... 11-164 11.12.6.4Telecom Receive FIFO Service Request Flag (TRS) (read-only, maskable interrup
                    
                    Resumo do conteúdo contido na página número 15 
                    
                        11.12.12.1Transmit FIFO Not Full Flag (TNF) (read-only, noninterruptible)............................................... 11-181 11.12.12.2Receive FIFO Not Empty Flag (RNE) (read-only, noninterruptibl11-181 11.12.12.3SSP Busy Flag (BSY) (read-only, noninterruptible)............................................... 11-181 11.12.12.4Transmit FIFO Service Request Flag (TFS)  (read-only, maskable interrupt)............................................ 1-181 11.12.12.5Receive FIFO Service Request Flag (R
                    
                    Resumo do conteúdo contido na página número 16 
                    
                        16.4 Instruction Register.......................................................................................... 16-2 16.5 Public Instructions ........................................................................................... 16-2 16.5.1 EXTEST (00000) ................................................................................ 16-3 16.5.2 SAMPLE/PRELOAD (00001) ............................................................. 16-3 16.5.3 CLAMP (00100)................................
                    
                    Resumo do conteúdo contido na página número 17 
                    
                        Figures 1-1 SA-1100 Features.............................................................................................. 1-1 1-2 SA-1100 Example System................................................................................. 1-5 2-1 SA-1100 Block Diagram .................................................................................... 2-2 2-2 SA-1100 Functional Diagram............................................................................. 2-3 2-3 SA-1100 Memory Map............
                    
                    Resumo do conteúdo contido na página número 18 
                    
                        11-24 HP-SIR Modulation Example....................................................................... 11-104 11-25 UART Frame Format for IrDA Transmission (<= 115.2 Kbps) .................... 11-105 11-26 4PPM Modulation Encodings ...................................................................... 11-105 11-27 4PPM Modulation Example ......................................................................... 11-106 11-28 High-Speed Serial Frame Format for IrDA Transmission (4.0 Mbps)..........
                    
                    Resumo do conteúdo contido na página número 19 
                    
                        10-5 DRAM Memory Size Options......................................................................... 10-14 10-6 DRAM Row/Column Address Multiplexing .................................................... 10-14 11-1 Peripheral Control Modules’ Register Width and DMA Port Size .................... 11-2 11-2 Peripheral Units’ Base Addresses ................................................................... 11-3 11-3 Peripheral Units’ Interrupt Numbers ..............................................
                    
                    Resumo do conteúdo contido na página número 20