IntelliG 1000
Model 3024 and 3024H
GARAGE DOOR OPENER
OPERATION AND MAINTENANCE MANUAL
® ®
Includes INTELLICODE 2 Remote Control. Safe-T-Beam System must be installed to close door.
For use only with residential sectional or one piece overhead garage doors.
® ®
Homelink and Car2U compatible.
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
WARNING: To reduce the risk of injury to persons or damage to property – Use this opener only with a one piece 
or sectional door.
                    
                    Краткое содержание страницы № 2 
                    
                        SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION CONVENTIONS USED IN THESE INSTRUCTIONS Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors.  Since moving  objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading  the information in this manual.  If you have questions or do not understand the information presented, call your nearest tr
                    
                    Краткое содержание страницы № 3 
                    
                        OPENER FEATURES INTELLICODE® 2 Access Security System A new generation superior encryption system  that enhances the security of the door opener by continuously  changing the access code each time the remote is used.  The door opener responds to each new code only once.   An access code copied from a working system and tried again will not control the door opener. Wall Console, Series III Operates door opener from inside garage.  The Wall Console has an Indicator Light with: Open/Close, Sure-Loc
                    
                    Краткое содержание страницы № 4 
                    
                        TABLE OF CONTENTS Section  ....................................................................................Page Safety Information  .................................................................................................... 2 Opener Features & Safety Features ................................................................... 3 Table of Contents  ....................................................................................................... 4 Installation  Important Installa
                    
                    Краткое содержание страницы № 5 
                    
                        Begin here after the opener's physical assembly  and installation has been completed.   There are no assembly or installation steps included in this manual.  Contact  your Genie® Professional Dealer for an installation poster, if required, or visit  www.geniecompany.com to download a PDF file.  The following mechanical assembly tasks must be completed before continuing.  Powerhead and rail are bolted to each other  (An illustration is shown on page 11) Example illustrations of the following ite
                    
                    Краткое содержание страницы № 6 
                    
                        ©2010  The Genie Company 12/2010 6 NOTICE I IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE WARNING PROGRAMMING LIMITS & FORCE  1 (Continuing from Installation Poster if provided) � Make sure doorway is in view and clear of obstacles  and people to avoid injury or damage to property. SETTING & TESTING LIMITS AND FORCE � DO NOT operate this unit from wall console before  The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making  LIMITS and FORCE are set.  Severe damage to the  a
                    
                    Краткое содержание страницы № 7 
                    
                        ©2010     The Genie Company 12/2010 7 NOTICE I IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE B) OPEN DOOR TRAVEL LIMIT PRESS and HOLD until door is FULLY OPEN then RELEASE 6 7 8 PRESS and  PRESS and  RELEASE RELEASE Watch door move Door Limits are set. Both LEDs flash Blue  and go OFF. Continue with  SEE long Blue LED  Step 9  SET FORCE. NOTE: You can start and stop door  flashing movement using either   buttons until  door is in correct open or closed position. 10 SET FORCE Force is set automa
                    
                    Краткое содержание страницы № 8 
                    
                        ©2010  The Genie Company 12/2010 8 CONTACT REVERSE TEST  WARNING   The Force and Limit settings on the previous page MUST be COMPLETED before Contact  A moving door can cause serious injury or death. Reverse testing. 1.  Keep people clear of opening while door is moving. 2.  Do NOT allow children to play with opener, including  1. Test. wall console, remote, or wireless keypad. �  Open garage door using wall console. 3.  During programming, door opener could begin to run,  –  Place a 2" x 4" boa
                    
                    Краткое содержание страницы № 9 
                    
                        ©2010     The Genie Company 12/2010 9 PROGRAM INTELLICODE® 2 REMOTE TO POWERHEAD FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM 2 Bring remote(s) to powerhead location.     WARNING   Begin with Step 1 and continue through Step 7 for each button to be programmed. A moving door can cause serious injury or death. NOTE: The following instructions are for the remote(s) provided with this opener.  This  1.  Keep people clear of opening while door is moving. remote is preset for use with the IntelliCo
                    
                    Краткое содержание страницы № 10 
                    
                        ©2010  The Genie Company 12/2010 10 Homelink® programming OPTIONAL      PROGRAMMING POWERHEAD TO Homelink®, Car2U®, or IntelliCode® 1 REMOTES and  IntelliCode® 1 WIRELESS KEYPADS If your Homelink® has been previously programmed to an  Genie® opener begin with Step 1 and continue through Step  To complete any of these tasks you MUST have at least one Genie® IntelliCode® 2 remote  5 and 6 of the Homelink® section below. button already programmed to the powerhead present. If your Homelink® has not 
                    
                    Краткое содержание страницы № 11 
                    
                        REFERENCE  - POWERHEAD & RAIL ASSEMBLED VIEW    RÉFÉRENCE – VUE DE LA TÊTE D’ALIMENTATION & DU RAIL ASSEMBLÉ REFERENCIA - VISTA DEL CABEZAL ELÉCTRICO Y RIEL ENSAMBLADOS NOTE: Use wall console and safety sensors provided with this unit.  Do NOT substitute wall console or safety sensors. REMARQUE: Utilisez la console sur le mur et les capteurs de sécurité fournis avec cet appareil. NE PAS substituer la console du mur ou les capteurs de sécurité. NOTA: Use la consola de pared y los sensores de segu
                    
                    Краткое содержание страницы № 12 
                    
                        NOTICE IF DOOR BECOMES OBSTRUCTED I PULL DOWN ON HANDLE 3 TYPICAL SECTIONAL DOOR INSTALLATION   FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM INSTALLATION TYPIQUE SUR UNE PORTE SECTIONELLE .................................POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE UNA PUERTA SECCIONAL ................................. PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician.  Power cord must 
                    
                    Краткое содержание страницы № 13 
                    
                        I IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE TYPICAL ONE PIECE DOOR INSTALLATION    ........... FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM INSTALLATION TYPIQUE D’UNE PORTE DE GARAGE D’UNE PIÈCE  .............POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE PUERTA DE UNA SOLA PIEZA ................................... PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician.  Power cord must r
                    
                    Краткое содержание страницы № 14 
                    
                         OVERVIEW OF POWERHEAD CONTROLS 4 This section describes the simple programming  Programming Overview functions.  Use this page to familiarize yourself with the  There are four Powerhead program menus: buttons and LED indicators used to program the opener. Remote Program (Default menu) NOTE: These  and  buttons are for programming use  only.  Do NOT use these buttons to operate the opener. Limits Program Speed Program* Force Program* Programming steps for Limits and remotes are found on  pages 6
                    
                    Краткое содержание страницы № 15 
                    
                         OVERVIEW - REMOTES AND OPTIONS   5 LOST OR STOLEN REMOTE - CLEARING MEMORY  WARNING   Clearing remotes from powerhead memory will  A moving door can cause serious injury or death. clear ALL programmed remotes and wireless  1.  Keep people clear of opening while door is  keypad. moving. 2.  Do NOT allow children to play with opener,  NOTE: Follow the PROGRAM REMOTE TO  including wall console, remote, or wireless  POWERHEAD steps to re-enter remaining or new  keypad. remotes.  See page 9. 3.  Dur
                    
                    Краткое содержание страницы № 16 
                    
                        ATTENTION If your garage door opener has a Serial Number sticker which  looks like this, in which the first two numbers are 10 or higher,  your opener is equipped with INTELLICODE®2. MODEL AC SR3 THE GENIE COMPANY FCC ID: B8Q AC SR3 Residential Door Operator IC:  2133A-CSD1D 120V. 60HZ. 5A S/N:10XXXXXXXXXXXX FOR HELP CALL 1-800-35GENIE OR WWW.GENIECOMPANY.COM Programming remote to previously installed  If you have another garage door opener that does NOT have  IntelliCode® 1 Genie® garage door o
                    
                    Краткое содержание страницы № 17 
                    
                        TRANSMITTER COMPLIANCE STATEMENT Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture.   No warranty is made that they comply with all legal requirements of any other jurisdiction.  If transmitters  are to be used in another country, the importer must determine compliance with any local laws and  regulations which may differ from United States and Canadian requirements prior to use. Los transmisores cumplen con todas las reglamentaciones legale
                    
                    Краткое содержание страницы № 18 
                    
                           WARNING WARNING    �  Garage door hardware (springs, cables, brackets, Use wall console supplied with opener.  Other  pulleys, etc.) are under extreme pressure and approved wall consoles may be available.  tension. Unapproved or incompatible wall consoles can  �  DO NOT attempt to repair or adjust door cause the opener to operate unexpectedly.  springs or any hardware, and DO NOT OPERATE  Safe-T-Beam® (STB) SYSTEM CHECK garage door automatically or manually if door  is improperly balanced or 
                    
                    Краткое содержание страницы № 19 
                    
                        NOTICE IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE CARRIAGE ENGAGE/DISENGAGE Use Release Handle to manually connect or release  chain or belt bullet to Carriage. TO RELEASE CARRIAGE: CHANGE LIGHT BULBS  1.  Pull handle DOWN then let go.   2.  Manually move door until carriage releases from bullet.    3.  Raise or lower door manually.  WARNING   �  Observe all safety warning and precautions!  Improper light bulb removal or replacement  could result in Death or Serious Injury. �  Disconnect pow
                    
                    Краткое содержание страницы № 20 
                    
                        B/W W B/W W This opener has a Serial Number sticker in which the serial  Open/Close Button numbers begin with 10 or higher.   Open and closes door from inside garage ATTENTION Sure-Lock™ Button If your garage door opener has a Serial Number sticker which  – LOCK disables controls    looks like this, in which the first two numbers are 10 or higher,  your opener will operate using this Series III wall control.  after door is completely    MODEL AC SR3 THE GENIE COMPANY  closed FCC ID: B8Q AC SR3 R