Краткое содержание страницы № 1 
                    
                         
Supported Equipment Manual 
For the BHT-7500 and BHT-103 Devices Manufactured by Denso Corporation 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Краткое содержание страницы № 2 
                    
                            Copyright © 1996 - 2006 by Connect, Inc.  All rights reserved. This document may not be reproduced in full or in part, in any form,  without prior written permission of Connect Inc., 1701 Quincy Avenue, Suites 5 & 6,  Naperville, IL 60540.  Connect, Inc. makes no representation or warranties with respect to the contents  of this document and specifically disclaims any implied warranties of  merchantability or fitness for any particular purpose. Further, Connect, Inc.  reserves the right to r
                    
                    Краткое содержание страницы № 3 
                    
                          Table of Contents  Chapter 1 • Introduction............................................................................................. 1-1  Release Notes…………….............................................................................................1-1  Descriptions………………............................................................................................1-1  Pictures…………………….. ..........................................................................................1-2  Setup Requi
                    
                    Краткое содержание страницы № 4 
                    
                          This page is intentionally blank.  iv Supported Equipment Manual   •    March, 2006                                                                                                                                                                                                                                                                                                                                                                                                                               
                    
                    Краткое содержание страницы № 5 
                    
                          Chapter 1 • Introduction  Release Notes  1. For the 7500W terminal only (not 7500S) in all emulations, setting the backlight  timer in the Timers tab to 5 seconds or more enables the backlight when the trigger  (or any key) is pressed.    2. For the 7500W terminal only (not 7500S) in all emulations, choosing Spec 1 in       the Mode scrolling list box under the Alarm tab enables vibrate only, and choosing     Spec 2 enables vibrate and beep.  3. Denso 103: firmware version E001 is required. De
                    
                    Краткое содержание страницы № 6 
                    
                        Introduction  • Scanner Unit   o laser scanning system  o scanning area of 520mm max. (*2)  o resolution of 0.127 mm (PCS=0.9 min.)    • Communications Unit  o Optical interface   Communication speed of 115.2 kbps max.    Communication system of Infrared interface (IrDA-SIR 1.0 compliant)  o Wireless interface utilizing SS wireless communications  o RS-232C 115.2 kbps max. Cable interface    The new features for the BHT-103 (above and beyond the 7500) are as follows.  • Touch screen  • PDF scann
                    
                    Краткое содержание страницы № 7 
                    
                          Setup Requirements  Setup Requirements  Installation of PowerNet Twin Client requires, at a minimum, the following:  • A Pentium-class processor   • 32 MB of RAM  • 10 MB of free hard disk space available  • Microsoft Windows 95, 98, ME, XP, or NT/2000 operating system    Accessories  The following accessories are available:    • IrDA communication unit CU-7001  • Battery charger C-700  • 4-slot battery charger C-750  • Software (see http://www.denso-id.com/Default.aspx?tabid=27)  o Ir-transfe
                    
                    Краткое содержание страницы № 8 
                    
                        Introduction  This page is intentionally blank. 1-4   Supported Equipment Manual    •   March, 2006                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Краткое содержание страницы № 9 
                    
                          Chapter 2 • Terminal Setup  Downloading From the WEB  The PowerNet Twin Client software package can be downloaded from the Connect web  site at http://www.connectrf.com. Click on Partner Services and then click on Software  Downloads. Select the file named PowerNet Twin Client for Denso.  Running Setup from a Download File  The downloaded file is a compressed archive. After extraction using a utility such as  WinZip or PKWARE, folders are created on the hard disk as shown in the following  fig
                    
                    Краткое содержание страницы № 10 
                    
                        Terminal Setup  Installation  The InstallShield wizard runs and presents the following screen.    Click on Next to begin the installation process.     To change the default Destination Location, click on Browse and select a location. Then  click on Next.   2-2   Supported Equipment Manual    •   March, 2006                                                                                                                                                                                                
                    
                    Краткое содержание страницы № 11 
                    
                          Installation    The default folder is PowerNet. This default may be changed either by selecting an  existing program group or by typing in a new name at the prompt. Then click on Next.     When the installation is complete, reboot the system to initialize the Twin Client  software.  a. To reboot the system immediately, click on Finish.   b. To reboot later, click on the option to restart the computer later, and then click on  Finish.       2-3 Supported Equipment Manual   •   March, 2006      
                    
                    Краткое содержание страницы № 12 
                    
                        Terminal Setup  Running the Manager  The PowerNet Twin Client Manager is the utility that manages the terminal software and  configurations.  Select Start, Programs, PowerNet, and Twin Client Manager. The PowerNet Twin  Client Manager screen appears as shown in the following figure. This is the  administrator's main screen, and all functions are accessed from its menu bar, tool bar,  and tabs.  Menu Bar  The menu bar provides access to the functions used to configure the terminals and  manage th
                    
                    Краткое содержание страницы № 13 
                    
                          Quick Start  Quick Start  Quick Start describes how to prepare the Twin Client Manager and the Denso terminal  for a Telnet session with the host. Following an initial serial download, the terminal  software and configuration is managed automatically, over the wireless network.  Note: Denso terminals are normally delivered with Denso files pre-installed.   Configuring the Manager  The first step is to configure the Twin Client Manager to meet site-specific requirements,  and then prepare it fo
                    
                    Краткое содержание страницы № 14 
                    
                        Terminal Setup    To set these addresses from the Settings menu, click on Servers and then click on Add.  Enter the name of each server, its IP Address and IP port (normally 23 for Telnet  servers), and emulation type. Then click on OK.     Repeat this step for each Telnet server the terminals are required to access. If an error is  made in the name, IP Address, IP Port number, or Terminal emulation type, click on the  line that is in error and then click on the Edit button to make the correctio
                    
                    Краткое содержание страницы № 15 
                    
                          Quick Start      Saving the Configuration  Click File and Save As. Enter a name for this configuration.       For the purposes of this example, the name is vt220.        2-7 Supported Equipment Manual   •   March, 2006                                                                                                                                                                                                                                                                                        
                    
                    Краткое содержание страницы № 16 
                    
                        Terminal Setup  Configuring the Terminal for Download  The terminal is prepared for the addition of Twin Client by booting to command mode,  selecting the program loader on the terminal, erasing the EEPROM, and setting the serial  port parameters as described in this section. This simple procedure is described in the  following sections, and requires only a few minutes to complete.  Connecting the Cradle  The terminal download requires a serial connection between the terminal and the PC  through
                    
                    Краткое содержание страницы № 17 
                    
                          Quick Start  SYSTEM MENU    1: EXECUTE PROGRAM  2: DOWNLOAD  3: UPLOAD  4: SET SYSTEM  5: TEST  6: VERSION  7: FTP  8: RF     In the Set System menu, there are eight settings. Cursor down or press 5:   Communication and press Enter.    SET SYSTEM    1: EXECUTE PROGRAM  2: DISPLAY  3: DATE /TIME  4: BARCODE  5: COMMUNCATION  6: KEY  7: RESUME  8: TCP/IP     There are four settings in the Set Communication menu. Select number 1: Optical and  press Enter.  SET COMMUNICATION    1: OPTICAL  2: CONN
                    
                    Краткое содержание страницы № 18 
                    
                        Terminal Setup  SET PROTOCOLS      1: SERIAL NO.   ON OFF  2: H. PARITY    ON OFF  3: LINKUP TIME      NONE   30    60    90   120  4: FIELD SPACE      IGNORE      DATA    When the settings have been recorded, press Enter. This will return the terminal to the  Set Communication Menu.     SET COMMUNICATION    1: PARAMETER  2: PROTCOL   Press 1 and Enter, and cursor to 115,200.    SET PARAMETER      1: TRANSMIT SPEED   2400       9600      19200  38400     57600    115200    Pres
                    
                    Краткое содержание страницы № 19 
                    
                          Quick Start    Press  to return to the Set Communication Menu. Press 3:  and Enter.    SET COMMUNICATION    1: OPTICAL  2: CONNECTOR  3: COM PORT  4: PROTOCOL TYPE     Press 1 for Basic Mode settings, and cursor to Optical.  Press 2 for System Mode settings, and cursor to Optical.    SET COM DEFAULT PORT     1: BASIC   OPTICAL    CONNECTOR    2. SYSTEM MODE   OPTICAL    CONNECTOR     Press  to return to the Set Communication Menu.  Press 4:  and Enter.    SET COM
                    
                    Краткое содержание страницы № 20 
                    
                        Terminal Setup    At the prompt, choose Yes or No to download configurations. Choosing Yes is needed to  run in Telnet mode.    The following screen will appear.    Choose OK at the prompt above.  Note: The screen above is for the BHT 103 terminal. The BHT 7500W terminal requires  special firmware version SB06, and the BHT 7500S terminal requires latest  firmware version 1.12.  At the same time, press 1 and Enter to start file download.    YMODEM MENU    1: DOWNLOAD  2: UPLOAD   The terminal wil