Краткое содержание страницы № 1 
                    
                        Thru-the-wall
Air Conditioners and Heat Pumps
115-Volt: WS08, WS10, WS12
230-Volt:  WS10, WS13, WS15, WE10, WE13, WE15, WY09, WY12
920-007-16 (5-10)
WallMaster
Installation and Operation Manual                                                                                                                                                                                                                                                                                                                   
                    
                    Краткое содержание страницы № 2 
                    
                        Table of Contents Your Safety and the safety of others .........................................................................................................................................3 General Information Economizing Tips  ........................................................................................................................................................................ 3 Electrical Data .................................................................................
                    
                    Краткое содержание страницы № 3 
                    
                        WELCOME to years of economical comfort These are some suggestions for saving money on cooling costs.  Your new Friedrich Room Air Conditioner has been carefully  Some, however, may not be applicable to your house or area. Check  engineered and man u fact ured to give you many years of de pend able,  with your local utility company for more especialized information.   efi cient operation, keeping your room at a comfortable temperature  and hu midi  ty level. Many extra fea tures have been built i
                    
                    Краткое содержание страницы № 4 
                    
                        How to operate your Friedrich room air cond it ione r To start unit To activate Smart Fan (WY/WE heat-cool models) If your air conditioner is installed and plugged into a proper re cep tac le,  9 Press the Smart Fan button to activate the Smart Fan. The light  it is ready to go. The f i rst time the unit is started, the compressor will  will indicate that this feature is in use. delay for three minutes. See Automatic Component Protection on the  Smart Fan will adjust the fan speed automatically 
                    
                    Краткое содержание страницы № 5 
                    
                        Digital Control Panels Using the remote control To start unit (See Figure 3, page 6) 1 POWER - Press the Power button once. The unit will automatically    start in the mode and fan speed it was last left on. PM To set mode of operation 2 C OOL - Press the Cool button to automatically switch the operat- Power  ing mode to COOL. Cool Fan ® Money Saver Speed Mode 3 FAN ONLY - Press the Fan Only button if you want to run the    Fan Only fan only.  Clock Timer Set Start Time 4 HEAT  (WY/WE models onl
                    
                    Краткое содержание страницы № 6 
                    
                        To set the timer NOTE: You can set the START and STOP times a minimum of one  hour apart, and a maximum of 23 hours apart. 10 TIMER START - Press Start to view the current start time for cool-   ing. Continue pressing the START button until you arrive at the start  Temperature Cooler Warmer time you desire. The start time for cooling will then be set. Power Cool Heat 11 TIMER STOP - Press the Stop button. Continue pressing the    Fan Fan Money STOP button until you arrive at the stop time you de
                    
                    Краткое содержание страницы № 7 
                    
                        Rotate How to change airfl ow direction The DISCHARGE GRILLE is installed at the factory to provide 45º upward airflow into the room. (Direction 1 in Figure 5).  If a vertical  WARNING air flow is desired (Direction 2), the direction can be changed by rotating  the DISCHARGE GRILLE.   Electrical Shock Hazard Unplug the air conditioner.   Use correct circuit protection. Failure to follow these instructions can Remove the DISCHARGE GRILLE RETAINER attached with one  result in death, fire, or electr
                    
                    Краткое содержание страницы № 8 
                    
                        WARNING Figure 6 NOTE: Your LCDI device will resemble one of these illustrations. Electrical Shock Hazard Do not use plug adapters. RESET TEST Do not use an extension cord. RESET Do not remove ground prong. Replace damaged cords with new cord WARNING TEST BEFORE EACH USE 1. PRESS RESET BUTTON from manufacturer. 2. PLUG LDCI INTO POWER  TEST     RECEPTACLE 3. PRESS TEST BUTTON, Failure to follow these instructions can      RESET BUTTON SHOULD                                    POP UP result in de
                    
                    Краткое содержание страницы № 9 
                    
                        Frosting of the indoor coil Things to know about a WallMaster heat pump Certain operating conditions may produce indoor coil frost. During During the heat pump operation, you may notice some functions that  the cooling operation, a dirty  filter or restricted air distribution in did not occur when the unit was used for cooling: combination with cool, damp weather could cause such an occurrence.  1. It is common for ice to form on the outdoor coil of your  Should the indoor coil frost over while 
                    
                    Краткое содержание страницы № 10 
                    
                        Installation requirements Sleeve installation STEP 1 The WSD SLEEVE should be positioned so that the STEP 1 After unpacking the WSD SLEEVE from the carton, remove  9 DRAIN EXTENSION extends a minimum of 16" beyond the FRONT PANEL. Place the WSD SLEEVE in the wall  the OUTSIDE WALL (See Figure 7). opening following the instructions given in the INSTALLA- TION REQUIREMENTS. Attach the SLEEVE to the  STEP 2 The WSD SLEEVE must extend a minimum of  ⅞" beyond  INSIDE WALL by driving two #12A x 2" scr
                    
                    Краткое содержание страницы № 11 
                    
                        STEP 3  The decorative front is packaged in a separate box inside  WallMaster chassis installation  the chassis shipping carton, be tween the chassis and  the carton. Remove this box and set the box aside until  instructions for WS, WE and WY  later. models  STEP 4 With the help of an assistant, remove the chassis from  the shipping carton. Be careful not to allow anything to  impact against the hairpins as this may result in dam age  CAUTION to them.  With the help of an assistant, lift the cha
                    
                    Краткое содержание страницы № 12 
                    
                        Figure 9 Chassis Seal  Gasket Decorative Front Screws (4) Return  Air  Grille Alternate drain kits WARNING Moving Object Hazard       Replace all panels before operating your air   conditioner.  Failure to do so can result in severe personal  injury or death and damage to product or  Drain nipple Drain hose other property.  Basepan Condensate removal (WS, WE  Figure 10 Sleeve and WY models) If you desire to drain condensate from the basepan during unit opera- DK (Drain Kit) tion, this unit is pr
                    
                    Краткое содержание страницы № 13 
                    
                        Friedrich Air Conditioning Company  P.O. Box 1540   San Antonio, TX 78295  210.357.4400  www.friedrich.com WALLMASTER THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY  FIRST YEAR  ANY PART:  If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from  date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible  for service.  Any additional labor cost for removing inaccessible