Краткое содержание страницы № 1 
                    
                         
 
 
  
 
 
 
 
 
  
 
 
 
 
102RAS 
Industrial  
Remote Access Server 
          
User Manual & 
Installation 
Guide 
 
 
 
 
 
 
 
 
 
 
 
(Revised 2010-11-15)                                                                                                    page 1 of 30                                                                                                                                                                                                                                  
                    
                    Краткое содержание страницы № 2 
                    
                              Table of Contents    Industrial Remote Access Server Installation Guide .....................................................................................3  General Safety Warnings ...............................................................................................................................4  Environmental Safety.....................................................................................................................................5  Electrical Safety ......
                    
                    Краткое содержание страницы № 3 
                    
                                  Industrial Remote Access Server Installation Guide     102RAS                                           The N-TRON 102RAS provides connectivity to an industrial LAN for telecommuters or mobile  users, or to remotely installed equipment, via an integrated V.92/56K modem.  The small size of the  102RAS makes it ideal for placing alongside other industrial equipment to be accessed remotely.    Product Features     LAN Port:  10/100BaseT; RJ-45   WAN Port:  V92/56K modem; RJ-11   Rates:  D
                    
                    Краткое содержание страницы № 4 
                    
                                Copyright, © N-Tron Corp., 2008  820 S. University Blvd., Suite 4E  Mobile, AL  36609    USA    All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-Tron  Corp. is prohibited, except as allowed under copyright laws.    Ethernet is a registered trademark of Xerox Corporation.  All other product names, company names, logos  or other designations mentioned herein are trademarks of their respective owners.    The information contained in this 
                    
                    Краткое содержание страницы № 5 
                    
                              Environmental Safety      WARNING:  Disconnect the power and allow to cool 5 minutes before touching.    Electrical Safety      WARNING: Disconnect the power cable before removing any modules, or any enclosure panel.    WARNING: Do not operate the unit with the cover removed.    WARNING: Properly ground the unit before connecting anything else to the unit.  Units not properly  grounded may result in a safety risk and could be hazardous and may void the warranty.  See the grounding  techniq
                    
                    Краткое содержание страницы № 6 
                    
                              5. Class I, Div 2 Installations require that power connections must be current limited at the power source  with an in-line fuse rated at 0.5A.    6. Class I, Div 2 installations require that all devices connected to this product must be UL listed for the  area in which it is installed.    7. Use 60/75ºC rated Copper wire, (022Nm) 2 inch-lbs Tightening torque for field installed connectors.    8. Limited Operating Voltage: 10-30V for Class I, Div 2 installations.    9. This apparatus is su
                    
                    Краткое содержание страницы № 7 
                    
                              DIN Rail Mounting    Install the unit on a standard 35mm DIN rail.  Recess the unit to allow at least 3” of horizontal clearance for  cable bend radius.                                         To mount the unit to the 35mm DIN rail,      To remove the unit from the 35mm DIN rail, typically  place top edge of the brackets on the back of the it is possible to remove the unit by using your index and  unit against the DIN rail at a 45° upward angle. middle fingers or use flat head screwdrivers
                    
                    Краткое содержание страницы № 8 
                    
                              Front Panel                                From Top to Bottom:           Green LED lights when Power is supplied to the module RJ-45 Port Auto sensing 10/100 Base-TX Connection  RJ-11 Port Phone line connection  TR     Transmit Ready  CD     Carrier Detect  TX     Transmit  RX     Receive    Note: The RJ45 data port has two LED’s located at the side of the connector.  The bottom LED indicates  LINK status, and the top LED indicates ACTIVITY.    LED’s:  The table below describes the operati
                    
                    Краткое содержание страницы № 9 
                    
                              Applying Power (Top View)         Remove Supplied #6 Phillips head grounding screw from top of unit.   Connect ground wire with lug (not supplied) and re-install the grounding screw securely.    Unscrew & Remove the DC Voltage Input Plug from the Power Input Header   Install the DC Power Cables into the Plug (observing polarity).   Plug the Voltage Input Plug back into the Power Input Header.   Tightening torque for the terminal block power plug is 0.22 Nm/0.162 Pound Foot.   Verify the Po
                    
                    Краткое содержание страницы № 10 
                    
                              N-TRON SWITCH GROUNDING TECHNIQUES    The grounding philosophy of any control system is an integral part of the design.  N-Tron switches are  designed to be grounded, but the user has been given the flexibility to float the switch when required.  The  best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to  earth ground via a drain wire.  Some N-Tron switches have metal din-rail brackets that can ground the  switch if the din-rail is grounded
                    
                    Краткое содержание страницы № 11 
                    
                              RJ45 CONNECTOR CRIMP SPECIFICATIONS    Please reference the illustration below for your Cat5 cable specifications:  (Revised 2010-11-15)                                                                                                    page 11 of 30                                                                                                                                                                                                                                                     
                    
                    Краткое содержание страницы № 12 
                    
                                Overview of Features    Compact Remote Access Solution     The 102RAS includes one integrated V.92/56K modem, housed in a compact, industrial chassis which  provides V.92/56K download speeds and 48K upload speeds when connecting with V.92 servers. Dial-in  users can achieve V.34/33.6K connections. Unit ships with 35mm DIN rail connector suitable for mounting  the unit on 35mm DIN rail in industrial environment.    Secure Remote Access    The 102RAS has a built-in security database for us
                    
                    Краткое содержание страницы № 13 
                    
                              Troubleshooting  1. Make sure the  (Power LED) is ON.  2. Make sure you are supplying sufficient current.  Note:  The Inrush current will exceed the  steady state current by ~ 2X.  3. Verify that Link LED’s are ON for connected ports.  4. Verify cabling used between stations.  5. Verify the phone socket that the phone line from the 102RAS is plugged into is operational.    6. Verify that cabling is Category 5E or greater for 100Mbit Operation.    Support:    Contact N-Tron Corp. at:  TEL: 
                    
                    Краткое содержание страницы № 14 
                    
                              Regulatory Statements    47 CFR Part 15 Regulation    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) this device may not cause harmful interference, and (2) this device must accept any interference  received, including interference that may cause undesired operation.    Industry Canada    This Class A digital apparatus complies with Canadian ICES-003.    Cet appareil numérique de la classe A est conforme à la norme NMB-o003 du
                    
                    Краткое содержание страницы № 15 
                    
                              9.  If your home or office has specially wired alarm equipment connected to the telephone line, ensure  the installation of this equipment does not disable your alarm equipment.  If you have questions  about what will disable alarm equipment, consult your telephone company or a qualified installer.  10. This equipment is hearing aid compatible.  11. Manufacturing Information:  Manufacturer:    N-Tron Corp.  Trade Name:    102RAS  Model Number:   102RAS  Registration No:   AU7USA-25814-M5-E
                    
                    Краткое содержание страницы № 16 
                    
                              restricted to lower bit rates when connected to some PSTN implementations.  Telecom will accept no  responsibility should difficulties arise in such circumstances.  2.  Immediately disconnect this equipment should it become physically damaged, and arrange for its  disposal or repair.  3.  This modem shall not be used in any manner which could constitute a nuisance to other Telecom  customers.  4.  This device is equipped with pulse dialing, while the Telecom standard is DTMF tone dialing. 
                    
                    Краткое содержание страницы № 17 
                    
                              China     Approved  20650004500320  China NALTE    Approved  10-6066-060989    Cyprus     Approved   CE  Czech Republic   Approved   CE  Denmark    Approved   CE  Estonia    Approved   CE  Finland    Approved   CE  France     Approved   CE  Germany    Approved   CE  Greece     Approved   CE  Hong Kong    Approved  SL 300063  Hungary    Approved   CE  Iceland     Approved   CE  India     Approved  TEC/NR/I/MOD-08/01/082.JUL03  Indonesia    Approved  01144/1/POSTEL/2003  Ireland     Approved
                    
                    Краткое содержание страницы № 18 
                    
                              Software Configuration    Web Management     Enter the switch’s IP address in any web browser and login to the web management feature of the  102RAS.                  Default:   Username: admin   Password: admin        (Revised 2010-11-15)                                                                                                    page 18 of 30                                                                                                                                              
                    
                    Краткое содержание страницы № 19 
                    
                              Web Management - Home    When the administrator first logs onto the 102RAS, the default home page is displayed.  At the top  of the screen there is a list of configurable settings which the 102RAS supports.  This section of the manual  will go through each choice listed at the top of the screen and explain how to configure those settings.  In  the center of the main home page the administrator/user can see some basic information like what firmware  revision the 102RAS is running.    (Revis
                    
                    Краткое содержание страницы № 20 
                    
                              Web Management – Menu Structure        Home   Shows information about the manufacturer and the 102RAS, along with support Website and E-Mail  addresses.  Login    Brings up the Login page    Logout    Logs off the current user    Administration   IP Configuration  – Shows the current IP Configuration and allows User to change.   SMTP Configuration – Shows the current SMTP Configuration and allows User to change.   Time Configuration  – Shows the current Time Configuration and allows User t