Краткое содержание страницы № 1 
                    
                         
 
 
Daylight Corrected, Constant Color  
 
 
 
StudioMax ® III 
 
 
Operator’s Manual 
 
Studio Max ® III AKC320 
   Studio Max ® III AKC320B 
Studio Max ® III AKC160 
   Studio Max ® III AKC160B                                                                                                                                                                                                                                                                                                               
                    
                    Краткое содержание страницы № 2 
                    
                        OPERATOR MANUAL FOR MONOLIGHTS    StudioMax ® III AKC320     StudioMax ® III AKC320B  StudioMax ® III AKC160     StudioMax ® III AKC160B    Thank you for selecting the Photogenic Professional  StudioMax ® IIII AKC series.  The StudioMax IIII series  incorporates state of the art electronic components, providing  economical lighting control, power setting repeatability and  corrected, constant color.  These products are built for the  operational needs of the semi-professional and amateur  photog
                    
                    Краткое содержание страницы № 3 
                    
                        SAFETY PRECAUTIONS    Despite the measures that have been taken to make electronic flash  equipment safe, it must be recognized that high voltages and high  temperatures do exist within the power supply / lighting unit.  Certain  precautions must be observed in handling the unit.  Contact with internal high voltage may result in severe injury or death.    1. Before installing or removing the flashtube and modeling  lamp, be sure this appliance is turned off, cooled and  unplugged from AC power s
                    
                    Краткое содержание страницы № 4 
                    
                        PREPARATION AND BASICS    Unpacking and Setup:    Unpack all units carefully to remove all parts from the carton(s).  Do  not discard or destroy the packing material until the equipment has  been inspected, assembled, and all parts accounted for.  After  unpacking, all parts should be examined for any damage, which  may have been caused by rough handling  during shipment.  If any  damage is detected, contact the delivering carrier at once.  Claim for  damage should be made to the delivering carr
                    
                    Краткое содержание страницы № 5 
                    
                        Reflector, soft box,  bare bulb, or other  “quick-change”  attachments.  Flashtube.  Modeling lamp.  Thumb screw to hold reflector.  Umbrella holder (shaft passes  through knock-out in reflector.)  Thumb screw for umbrella shaft.  AC line cord jack.        CONTROL PANEL AND BASIC OPERATION:        Power Input:    The power required to operate the StudioMax III is 105 to 125 volts AC,  50/60 Hz, 4 Amp, and/or, for a B (battery) model, an approved DC battery  power pack (not included).  The power 
                    
                    Краткое содержание страницы № 6 
                    
                        Circuit Protection:    Circuit protection (fuse) automatically protects this appliance from  excessive damage due to circuit or component failure.  Operation  exceeding the rated cycle of the appliance may cause the fuse to open.    [Always replace fuse with same rating of fuse.]    To replace a blown fuse (power cord must be disconnected), simply  unscrew the fuse holder cap (side front of unit) and replace the exposed  fuse with a new fuse.  If fuses continue to blow, contact your dealer or  q
                    
                    Краткое содержание страницы № 7 
                    
                        Modeling Light:    The modeling light has two modes of operation:  1.   With POWER switch in MODEL/FLASH upper position, the modeling  lamp is ON.  2.  With POWER switch in FLASH or center position, the modeling lamp is  OFF.  [Note: With battery models the modeling lamp is disabled to conserve the  available battery power.]    Test Function:    The TEST button is pressed to fire the flashtube for test purposes.    Power Off:    Turning OFF the POWER switch will turn OFF both the AC line power a
                    
                    Краткое содержание страницы № 8 
                    
                        Photocell/Slave:    The built-in photoslave is operational when the unit is ON.  If you  wish to disable the photoslave, plug in your SYNC cord.      AKC160 and AKC320 Accessories:    A large assortment of Photogenic standard “Quick-Change”  reflectors, umbrellas, grids, softboxes, snoots, barndoors and cases  are available.   AKC160B and AKC320B:    A battery pack power source (AKB-1) is available, as well as a large  assortment of Photogenic standard “Quick-Change” reflectors,  umbrellas, grid
                    
                    Краткое содержание страницы № 9 
                    
                        OPERATION    StudioMax III All Models  Flashing Rate:  The unit recharges quickly, as indicated by the READY light on the control  panel.  A quick series of flashes can be obtained within the limits of the  recharge time.  Continuous rapid flashing, however, can overheat and  damage the flashtube and internal parts.  The maximum recommended rate  of flashing depends upon the power level being used and the amount of  operation time.  Use the following chart to serve as a guide for the  maximum ra
                    
                    Краткое содержание страницы № 10 
                    
                        SPECIFICATIONS  AKC320 & AKC320B    General:    Flash Power....................................................10 to 320 watt-seconds.                                                                                (6 f-stops)  Flash Duration................................................1/120 second at Full  1/400 second at ½  1/840 second at ¼  1/1660 second at 1/8  1/2900 second at 1/16  1/4800 second at 1/32  Recycling time................................................0.02 to 3 seconds  Po
                    
                    Краткое содержание страницы № 11 
                    
                          SPECIFICATIONS  AKC160 & AKC160B    General:    Flash Power....................................................5 to 160 watt-seconds.                                                                                (6 f-stops)  Flash Duration................................................1/175 second at Full  1/700 second at ½  1/1300 second at ¼  1/2400 second at 1/8  1/4100 second at 1/16  1/7400 second at 1/32  Recycling time................................................0.01 to 1.5 seconds
                    
                    Краткое содержание страницы № 12 
                    
                          Color Temperature  Consistent and Constant  The problem: With the rare exception of units costing many  thousands of dollars, flash lighting packs, up to now, do not control  the color temperature of the light.  The color temperature typically  decreases by over 100 degrees Kelvin for every f-stop of power  reduction. Over a 6-stop adjustment range, this results in a color  temperature decrease of over 600K.  Even units that have a small 3- stop range can produce significant color shifts of ov
                    
                    Краткое содержание страницы № 13 
                    
                        film. The reciprocity law applies to commonly available black-and- white and color films at exposure times from approximately 1/10   second to 1/1,000 second. This means that no adjustments are  necessary for exposure or color in this shutter range. Most modern  films however have increased this range to the point that no  adjustments are necessary from approximately 1 second to  1/10,000 second. It should be pointed out that all photographic  emulsions are subject to an effect often called “rec
                    
                    Краткое содержание страницы № 14 
                    
                        SERVICE    The photographer should not attempt to make repairs.    Consult a dealer for an authorized Photogenic Professional Lighting service  agent.  This will provide you safety, insure proper operational functions and  provide continuation of your warranty.    Before removing the old tubes or installing new tubes, always  unplug your StudioMax and discharge the stored energy by  switching the POWER switch to OFF.  Wait approximately two hours  for the main capacitors to deplete any residual 
                    
                    Краткое содержание страницы № 15 
                    
                          General Trouble Shooting    COMMON PROBLEMS AND CAUSES    Unit does not charge.   Probable causes:  a. Fuse blown. (Unplug and discharge the unit-Replace fuse.)  b. No line power to unit. (Check line cord and outlet.)  c. Defective unit.  (Return for repair.)    Modeling light does not turn on.   Probable causes:  a. Lamp turned off. (Press FULL ON/OFF button until LED  lights.)  b. Lamp burned out. (Inspect and replace, when cool.  Replace  with same part number.)    Light flashes by itself w
                    
                    Краткое содержание страницы № 16 
                    
                                                          Photogenic Professional Lighting  1268 Humbracht Circle  Bartlett, Illinois  60103-1631 USA    Phone: (630)830-2500  Fax: (630)830-2525          Manual: # 016338-00  Revision: 01,  6-2005      16