Краткое содержание страницы № 1 
                    
                        PRIMESWITCH ™ 1 00/5 00 
PA P
USER GUIDE
®                                                                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Краткое содержание страницы № 2 
                    
                        ii   Document Number 10003137.00 Rev.1 Issued March 1998 NETWORK EQUIPMENT TECHNOLOGIES, INC., (N.E.T.) PROVIDES THIS  DOCUMENT AS IS, WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED  OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES  OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. This document constitutes the sole Specifications referred to in N.E.T.’s Product  Warranty for the products or services described herein. N.E.T.’s Product Warranty is  subject to all the condi
                    
                    Краткое содержание страницы № 3 
                    
                         iii Trademarks The N.E.T. logo is  a registered trademark, and PrimeSwitch, Network Equipment  Technologies and N.E.T. are trademarks of Network Equipment Technologies, Inc. All  other trademarks are the sole property of their respective companies. Note: In this manual, any reference to PrimeSwitch refers to the PrimeSwitch 100 Series    product line, unless specified differently.                                                                                                                    
                    
                    Краткое содержание страницы № 4 
                    
                        iv   10003137.00 Rev.1                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Краткое содержание страницы № 5 
                    
                         Contents  v Contents Introduction About this user guide,  1-2 Audience,  1-2 Using this guide,  1-3 Overview,  1-4 Filtering,  1-4 Buffering,  1-4 Display,  1-5 Basic Rate access,  1-5 Installation Installing PAP,  2-2 Local,  2-2 Remote via ADLM,  2-2 Remote via modem,  2-3 Connecting PAP to an ISDN interface module,  2-4 BRMN, BRMT and early IPMN and IPMT,  2-4 Later IPMN and IPMT,  2-4 QBRM and DTM,  2-4 Connecting PAP to a PC,  2-5 Software installation,  2-7 Starting PAP,  2-8 The PAP scre
                    
                    Краткое содержание страницы № 6 
                    
                        vi  Contents Commands Entering commands,  4-2 Keys,  4-3 Commands,  4-4 10003137.00 Rev.1                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Краткое содержание страницы № 7 
                    
                        Introduction 1-1 1Introduction                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Краткое содержание страницы № 8 
                    
                        1-2  About this user guide About this user guide This user guide describes the Protocol Analyzer Package (PAP). It covers the installation  and operation of the PrimeSwitch 100 Series Integrated Services Digital Network (ISDN)  PAP . PAP is available for both Primary Rate and Basic Rate in a number of protocol variations. The PrimeSwitch PAPTS14 is an ISDN Primary Rate monitor conforming to Austel  Specification TS14. The PrimeSwitch PAPTS13 is an ISDN Basic Rate monitor conforming to Austel  Sp
                    
                    Краткое содержание страницы № 9 
                    
                        Introduction 1-3 Using this guide The guide contains the following sections: Overview describes how PAP processes network traffic. The PAP screen describes the main screen and illustrates how PAP displays messages. Commands describes how to control PAP with function keys and typed commands. Installation describes how to install PAP and connect PAP to a PC. Technical assistance information If there is a problem using the N.E.T. products, call the N.E.T. Technical Assistance Center  (TAC) for assi
                    
                    Краткое содержание страницы № 10 
                    
                        1-4  Overview Overview The PrimeSwitch ISDN Protocol Analyzer Package (PAP) monitors and displays layer 1,  layer 2 and layer 3 protocol activity on a PrimeSwitch ISDN interface. PAP uses COM ports on the PC to transfer information to and from a PrimeSwitch ISDN  module. PAP can monitor multiple ISDN interfaces on PrimeSwitch 100 Series modules  which have more than one (for example, the DTM or QBRM), and can use either COM1,  COM2 or BOTH at the same time on the PC. When PAP is operating, all t
                    
                    Краткое содержание страницы № 11 
                    
                        Introduction 1-5 This default can be overridden from the command line as follows: PAPXXXX REAL forces the PAP software to use conventional memory and will  not operate if insufficient conventional memory is available. PAPXXXX VIRTUAL forces the PAP software to use Extended or Expanded memory  and will not operate if memory is not available. These overrides should not be used unless problems are experienced with the default. The size of the buffer therefore depends on the amount of memory (RAM) a
                    
                    Краткое содержание страницы № 12 
                    
                        1-6  Overview Figure 1 shows the relationship between CES, SAPI and TEI. Figure 1: CES, SAPI and TEI 10003137.00 Rev.1                                                                                                                                                                                                                                                                                                                                                                                              
                    
                    Краткое содержание страницы № 13 
                    
                        Installation 2-1 2Installation                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Краткое содержание страницы № 14 
                    
                        2-2  Installing PAP Installing PAP PAP can be used to monitor traffic on either a local or a remote PrimeSwitch. Local  To monitor local traffic connect the PC to the PrimeSwitch PAP connector, as in the  following diagram: PC PAP PrimeSwitch Figure 2: Local connection Remote via ADLM To monitor remote traffic, a V.24 ADLM must be installed in both the local and remote  PrimeSwitches. Connect the PAP connector to an ADLM V.24 port on the remote  PrimeSwitch, and connect the PC to an ADLM V.24 po
                    
                    Краткое содержание страницы № 15 
                    
                        Installation 2-3 Remote via modem You can also use a modem to monitor traffic on remote PrimeSwitches, as shown in Figure  4. PC PACER 2200 Modem Analog Network PAP PACER 2200 Modem PrimeSwitch Figure 4: Local connection via modem                                                                                                                                                                                                                                                                              
                    
                    Краткое содержание страницы № 16 
                    
                        2-4  Connecting PAP to an ISDN interface module Connecting PAP to an ISDN interface module BRMN, BRMT and early IPMN and IPMT You must place the PrimeSwitch PAP Module panel in the slot immediately to the right  of the ISDN interface module that you want to monitor, with the connector located at  the top. If necessary, rearrange the modules in the PrimeSwitch to clear the slot on the  right hand side of the ISDN interface module. Note that you must update the  configuration of the PrimeSwitch to
                    
                    Краткое содержание страницы № 17 
                    
                        Installation 2-5 Connecting PAP to a PC Connect the PrimeSwitch PAP protection device to a parallel port of the PC. To monitor local traffic: 1 Connect COM1 or COM2 on the PC to the 25-way D type connector on the  PrimeSwitch PAP panel using a straight through cable constructed according to Figure  5. 2 2 3 OR 2 3 3 7 7 5 DB 25 Female DB 25 Male DB 9 Male (to PC) (to PAP V.24 por t) (to built-in P AP por t) Figure 5: Local cable construction To monitor remote traffic: 1 Connect the PC to an ADLM
                    
                    Краткое содержание страницы № 18 
                    
                        2-6  Connecting PAP to a PC 2 Configure the ADLM V.24 as follows: Remote ON Auto answer Remote and local ON AT call control 19 200 Bit rate No Parity 1 Stop bits 8 Number of bits 10003137.00 Rev.1                                                                                                                                                                                                                                                                                                                
                    
                    Краткое содержание страницы № 19 
                    
                        Installation 2-7 Software installation The PAP software is installed as part of the PrimeSwitch Manager—NCS (Net Center  Software) installation process. To install individual versions: 1 Create a directory for the PAP software. Type: MD \PAP  2 Change to this directory. Type: CD \PAP  3 Insert the PAP disk (PM-NCS Disk 3) into the floppy drive and change to the PAP  subdirectory. Type: CD A:\PAP  4 Expand the required file. Type: expand A:PAPTS14.EXE  expand A:PAPTS13
                    
                    Краткое содержание страницы № 20 
                    
                        2-8  Starting PAP Starting PAP To start the program: 1 Either: • from Program Manager, double-click on the icon; or • from MS-DOS, change to the PAP directory and type one of the following: PAPTS14  PAPTS13  PAPETSI  PAPETSIB  PAPDASS2  PAPDPNSS  To change the COM port or baud rate settings, use the Port and/or Rate commands (see  Chapter 4 — Commands). Changes are saved when the program exits and will be used  each time the program starts. 10003137.00 R