Краткое содержание страницы № 1 
                    
                          I N S T A L L A T I O N
 I N S T R U C T I O N S                                            
CARE AND USE MANUAL FOR:
CLASSICAL  ISLAND RANGE HOODS 
Models covered by these instructions:
SIU3, SIU4, SIU5, SIU8, 
* * * B E F O R E I N S T A L L A T I O N * * *
ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED 
DURING SHIPPING  
* * * S H I P P I N G D A M A G E * * *
MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT 
Telephone (Toll Free):  866.528.4987    Fax (Toll Free):  866.365.9204
www.siriush
                    
                    Краткое содержание страницы № 2 
                    
                        W A R N I N G S Thank you for purchasing a Sirius Range Hood. Please read all the          instructions in this manual before installing the appliance.   Save these instructions for future reference. The appliance is not intended for use by young children or infirm persons without supervision.   Young children should be supervised to ensure they do not play with the appliance.  If the  range hood is vented, the air so vented must be ducted into a dedicated duct that is not showed  with any other
                    
                    Краткое содержание страницы № 3 
                    
                        TABLE OF CONTENTS BEFORE YOU BEGIN 1 MINIMUM AND MAXIMUMS 1 DUCTING 1 Duct Run Calculation 2 ELECTRICAL 2 Electrical Supply 2 INSTALLATION 2 Structural preparation for the hood fan 2 installation  Fixing the Main Support Bracket 3 Attaching the range hood to the ceiling 4 Connecting Electricity and Ducting 4 Re-Circulating Requirements 4 Schematic of Classical Island Components 5 OPERATING PROCEDURES 6 General Advice 6 Functions 6 MAINTENANCE 7 Cleaning the Filter 7 Cleaning  the Hood 7 Light Bu
                    
                    Краткое содержание страницы № 4 
                    
                        B E F O R E Y O U B E G I N The manufacturer declines all      BEFORE STARTING – please read  responsibility in the event of failure this entire document and ensure you  to observe the instructions given are fully conversant with the require- here for installation, maintenance ments and limitations. These units  and suitable operation of the            weigh approximately 125lbs and  product.  The manufacturer further therefore require a minimum of two  declines all responsibility for injury peo
                    
                    Краткое содержание страницы № 5 
                    
                        heaters. To minimize the risk of based on the table below.  drawing these lethal gases back into  Maximum Run the home, please follow the heating  6” or 3 1/4 x 10” duct 100 FT equipment manufacturers safety  Deduct standards and guidelines. Refer to  NFPA and ASHRAE for additional  Each 90 elbow used 15FT information.  Each 45 elbow used 9FT Each 6” or 3 1/4 x 10” duct Duct Run Calculation  Transition used 1FT The maximum duct run before     Each 3’1/4 x 10”  to 6”  effecting the performance of
                    
                    Краткое содержание страницы № 6 
                    
                        and ideally not higher than 32”above  the frame by screwing through the     the cook-top. It is strongly              ceiling into the heavy members     recommended, at this point, that  inside the ceiling. This is critically  calculations and measurements be  important as the entire hood fan  made and all planning and heights  hangs from this position, and    be finalized. You will need to fit the  ceiling board alone will not            appropriate length of ducting to the  support the weight 
                    
                    Краткое содержание страницы № 7 
                    
                        items “B” on the schematic on page.  machine screws at point “E” on the  5. schematic on page 5 – THIS MUST  BE DONE IMMEDIATELY AND  Check that the plastic flaps at the  SHOULD NOT BE SKIPPED. exhaust outlet for the fan move  freely and have not become jammed  Ensure the entire structure is sturdy   during shipping or whilst working  - serious injury, death and MAJOR  with the power unit. Connect an   damage could result should the unit  appropriate length of ducting to the  not be well connect
                    
                    Краткое содержание страницы № 8 
                    
                        The deflector connects to the top of through the grills on the side of the  Bracket “A” and forces the air out chimney   section back into the  room. SCHEMATIC OF MODULAR ISLAND COMPONENTS 5                                                                                                                                                                                                                                                                                                                      
                    
                    Краткое содержание страницы № 9 
                    
                        O P E R A T I N G P R O C E D U R E S Never pick up a flaming pan – you  Read all the instructions before    may be burned.  DO NOT USE    operating the appliance.   WATER including wet dishcloths or  Save these instructions for future  towels, as a violent steam explosion  reference. may occur. General Advice Functions Ensure that the grease filters are in  Classical Island Range Hood – place.  Without these components,        Mechanical push buttons: operating blowers could catch on to  A: Lig
                    
                    Краткое содержание страницы № 10 
                    
                        M A I N T E N A N C E On the surfaces that are exposed  The hood-fan should provide many  directly to heat from the cook-top, it  years of trouble free service         is advisable to clean these on a  provided it is maintained properly.  regular basis, to avoid the marks  from becoming baked on.   Cleaning the Filter Do not under any circumstances use  Clean the grease filter either by  an abrasive type cleaner as this will  carefully hand washing (so as not to   scratch and damage the stainles
                    
                    Краткое содержание страницы № 11 
                    
                        T h r e e Y e a r L i m i t e d W a r r a n t y WARRANTY SERVICE To qualify for warranty service, you must notify Sirius Range Hoods at the      address stated below or call  toll free USA or Canada 1-866-528-4987 and     provide the model number, description of the fault or defect and original date of  purchase. Sirius reserves the right to request proof of original purchase. Sirius  will at its sole option and discretion replace products that arrive damaged  through shipping, provided shipping
                    
                    Краткое содержание страницы № 12 
                    
                        USA: CANADA: SIRIUS RANGE HOODS (USA) LTD. SIRIUS RANGE HOODS LTD. 1051 Clinton Street 1252 Speers Road Unit 11 Buffalo, NY 14206 Oakville, ON L6L 5N9 Telephone (Toll Free):  866.528.4987 Telephone:  905.257.0046 Fax (Toll Free):  866.365.9204 Fax:  905.847.0330 www.siriushoods.com                             Email:  info@siriushoods.com