Краткое содержание страницы № 1 
                    
                        Wood burnIng FIrepla Ce
oWner’s opera TIon and InsT alla TIon Manual
ICC-ES #ESR-2542
Models (V)C36, (V)C36I, (V)C36H, (V)C36l, (V)C36lI,  
(V)C36lH and CWC36C
SAVE THIS BOOK
This book is valuable. In addition to instructing you 
on how to install and maintain your appliance, it also 
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep 
it with your other important papers.
This fireplace is approved for use as a wood burning fire-
place or
                    
                    Краткое содержание страницы № 2 
                    
                        Table oF ConTenTs Safety .................................................................. 2 Operation and Maintenance .............................. 14 Specifications ...................................................... 3 Technical Service............................................... 15 Fireplace Installation............................................ 4 Parts .................................................................. 16 Venting Installation ........................................
                    
                    Краткое содержание страницы № 3 
                    
                        speCIFICa TIons GAS LINE RIGHT SIDE ELECTRICAL KNOCK  OUTS 1" AIRSPACE OUTLET TO COMBUSTIBLE MATERIAL 0" TO 8.125" NO COMBUSTIBLE  TOP 2.5" MATERIAL ON FACE SPACERS 7.092" 8.717" AIR KIT  11.217" KNOCK OUT  LEFT SIDE GAS LINE KNOCK  COMBUSTIBLE WALL BOARD OUTS 0.75"  AIR 10.435" 8.125" SPACE  2.5" BACK  AND  SIDES 8.717" NOT LESS  THAN 12" TO 14.437" OUTSIDE  PERPENDICULAR  AIR (LEFT  SIDEWALL SIDE ONLY) HEARTH  0" TO EXTENSION BOTTOM 52" X 16" 8" EACH  SIDE 29" 22" 14.25" 21" 12.5" 32.5" 41" 0.
                    
                    Краткое содержание страницы № 4 
                    
                        FIrepla Ce InsT alla TIon 3. Set fireplace directly in front of this open- SELECTING LOCATION ing and slide unit back until nailing flanges  To determine safest and most efficient location  touch side framing. for fireplace, you must take into consideration  4. Check level of fireplace and shim with  the following guidelines: sheet metal if necessary. 1. Location must allow for proper clearances  5. Before securing fireplace to prepared  (see Figures 1 and 2). framing, ember protector must be pl
                    
                    Краткое содержание страницы № 5 
                    
                        FIrepla Ce InsT alla TIon Continued HEARTH ExTENSION Seal Gap Fireplace Front A hearth extension projecting a minimum of  16" in front of and a minimum of 8" beyond  each side of fireplace opening is required to  Ember Protector protect combustible floor construction in front  of fireplace. Fabricate a hearth extension  using a material which meets the following  NO specifications: a layer of noncombustible,  inorganic material having a thermal conductiv- Do Not Block Louver Hearth  ity of K=0.8
                    
                    Краткое содержание страницы № 6 
                    
                        FIrepla Ce InsT alla TIon Continued MANTELS FAN/BLOWER KIT ASSEMBLY A mantel may be installed if desired (see Fan or blower kit is optional with this fireplace  Figures 4 and 5). Woodwork such as wood (circulating models only). Use of blowers or  trims, mantels or any other combustible fans other than those manufactured by DESA  material projecting from front face, must not Heating, LLC voids warranty. Fan is operated  be placed within 9" of fireplace opening and by pressing rocker switch (see F
                    
                    Краткое содержание страницы № 7 
                    
                        VenTIng InsT alla TIon OPTIONAL OUTSIDE AIR KIT   WARNING: The opening in  (MODEL AK4/AK4F) collar around chimney at top of  Installation of an outside air kit should be  fireplace must not be obstructed.  performed during rough framing of fireplace  Never use blown insulation to fill  due to the nature of it's location. Outside com- bustion air is accessed through a vented crawl  chimney enclosure. space (AK4F) or through a sidewall (AK4).  3 See Figure 24 on page 15 for instruction of  12 /8" 
                    
                    Краткое содержание страницы № 8 
                    
                        VenTIng InsT alla TIon Continued Continue to assemble chimney sections as  ASSEMBLY AND INSTALLATION OF  outlined, making sure that both inner and  DOUBLE WALL CHIMNEY SYSTEM outer pipe sections are locked together. When  Each double wall chimney section consists of  installing double wall snap-lock chimney to- a galvanized outer pipe, a stainless steel in- gether, it is important to assure joint between  ner flue pipe and a wire spacer. Pipe sections  chimney sections is locked. Check by pullin
                    
                    Краткое содержание страницы № 9 
                    
                        VenTIng InsT alla TIon Continued See Detail A Ceiling Support  Pipe 12S-8DM 2" Min. See Detail B Straps Straps Straps Straps Detail A Detail B  Return Elbow Angle  Firestop Figure 10 - Ceiling Support Pipe  12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 3 3 4 / " 16 / " ELBOW SET ONLY 8 8 3 1 9 / " 25 / " 1 4 2 3 3 12 / " 30 / " 1 4 4 3 15" 34 / " 1 4 18" 40" 1 1 1 1 21 /4" 46 /4" 1 3 1 23 / " 49 / " 1 1 4 4 3 3 27 / " 56 / " 1 4 4 3 30" 60 / " 1 1 4 B Screws 33" 66" 1 1 36" 71" 1 1 
                    
                    Краткое содержание страницы № 10 
                    
                        VenTIng InsT alla TIon Continued 4. Remove shingles around opening mea- FIRESTOP SPACERS (v3600FS-8DM) sured. Cut out this section. Firestop spacers are required at each point  5. Add next sections of pipe until end  where chimney penetrates a floor space.  Their purpose is to establish and maintain penetrates roof line. Check to see that  proper clearances are maintained. Extend  required clearance between chimney and  chimney by adding sections of double wall  combustible materials. When pipe 
                    
                    Краткое содержание страницы № 11 
                    
                        18" MIN. TYP. 24" MIN. 24" MIN. VenTIng InsT alla TIon Continued Terminations with 16" slip pipe sections are  Overlap  Storm Collar Shingles Top available. RTT-8DM and RTTL-8DM are  Flashing  and Sides Only approved for flashing installations. When  Cone needed, these adjustable terminations may  Nail Only  be used in combination with pipe assembly  Outer  to achieve correct chimney height. Perimeter  Note: In rare instance there is a problem with  of Flashing side driven rain or wind or chimne
                    
                    Краткое содержание страницы № 12 
                    
                        VenTIng InsT alla TIon Continued 10 FOOT RULE FINISHING THE FIREPLACE All flue gas outlet chimney terminations must Combustible materials, such as wallboard,  extend a minimum of 3 feet in height above gypsum board, sheet rock, drywall, plywood,  highest point where it passes through roof and etc. may make direct contact with sides and  must be at least 2 feet above highest point of top around the fireplace face. It is important  the roof that is within a horizontal distance of that combustible 
                    
                    Краткое содержание страницы № 13 
                    
                        opTIonal gas lIne InsT alla TIon Gas line hook up should be done by your  supplier or a qualified service person.  WARNING: Do not operate an  Note: Before you proceed, make sure your  unvented gas log set in this fire- gas supply is turned off. place with chimney removed. Use only a 1/2" black iron pipe and appropri- If you install a decorative gas appliance (vent- ate fittings.  ed gas log), decorative gas appliance must  1. Remove knockout indentation on refracto- comply with the Standard for
                    
                    Краткое содержание страницы № 14 
                    
                        opTIonal gas lIne InsT alla TIon Continued  WARNING: If the fireplace  WARNING: When using a dec- has been used for wood burn- orative vented gas log, damper  ing, firebox and chimney must must be removed or permanently  be cleaned of soot, creosote and locked in fully open position and  ashes be a qualified chimney glass doors must be in fully open  cleaner. Creosote will ignite if position. heavily heated. opera TIon and MaInTenanCe GLASS DOORS Glass doors are optional with this fireplace.  Wh
                    
                    Краткое содержание страницы № 15 
                    
                        OPEN CLOSE opera TIon and MaInTenanCe Continued For further operating guidelines, instruc- OUTSIDE AIR AND DAMPER  tions and warranty information, please re- HANDLE OPERATION fer to your homeowner's guide or contact  Damper handle, which opens and closes  your authorized dealer. damper blade, is located in upper front face  Damper  of fireplace. Pushing handle into left of key- Handle way slot will free damper blade to automati- Keyway  cally open. Pushing handle into right will lock  Slot dampe
                    
                    Краткое содержание страницы № 16 
                    
                        p ar Ts WOOD BURNING FIREPLACE MODELS (v)C36, (v)C36I, (v)C36H, (v)C36L,  (v)C36LI, (v)C36LH, CWC36C  34 29 2 1 21 5 8 15 17 28 20 30 25 18 11 36/37 9 7 42 12 3 35 40/41 19 31 10 6 38/39 22 26 13 14 33 24 4 16 27 32 16 27 23 16 www.desatech.com 107777-01E                                                                                                                                                                                                                                                     
                    
                    Краткое содержание страницы № 17 
                    
                        ar p Ts WOOD BURNING FIREPLACE MODELS (v)C36, (v)C36I, (v)C36H, (v)C36L,  (v)C36LI, (v)C36LH, CWC36C This list contains replaceable parts used in your fireplace. When ordering parts, see Replace- ment Parts on page 18 of this manual. KEY NO. PART NO. DESCRIPTION QTY. 1 106638-01 Insulation Pan • • • 1 2 ** Fireplace Top • • • 1 3 106641-01 Fireplace Surround • • • 1 4 106642-01 Air Rod Retainer • • • 1 5 106643-01 Damper Rod Retainer • • • 1 6 ** Firebox Bottom • • • 1 7 ** Firebox Surround • • 
                    
                    Краткое содержание страницы № 18 
                    
                        repla CeMenT p ar Ts STANDARD BRICK LINER HERRINGBONE BRICK  vC36(I)/vC36L(I)/CWC36C LINER Left - 106658-01 vC36H/vC36LH Right - 106659-01 Left - 108164-01 Rear - 106660-01 Right - 108165-01 Bottom Rear 106661-01 Rear - 108166-01 Bottom Front 106662-01 Bottom Rear - 108167-01 Bottom Front - 108168-01 C36(I)/C36L(I) Left - 106658-02 C36H/C36LH Right - 106659-02 Left - 108164-02 Rear - 106660-02 Right - 108165-02 Bottom Rear - 106661-02 Rear - 108166-02 Front Rear - 106662-02 Bottom Rear - 108167-
                    
                    Краткое содержание страницы № 19 
                    
                        aCCessorIes Continued FIRESTOP SPACER v3600FS-8DM OUTSIDE AIR KIT FOR SIDE WALL  INSTALLATION - AK4 FAN KIT - BK3 OUTSIDE AIR KIT FOR FLOOR  INSTALLATION AK4F BLOWER KIT - BK SQUARE CHASE-TOP  TERMINATION ROUND TOP TERMINATIONS ET-8DM, ETO-8DM RT-8DM, RTL-8DM ECONO-TOP TERMINATION WITH  ROUND TOP TERMINATIONS WITH  SLIP SECTION SLIP SECTION ETL-8DM, ETLO-8DM RTT-8DM, RTTL-8DM 107777-01E www.desatech.com 19                                                                                           
                    
                    Краткое содержание страницы № 20 
                    
                        DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www.desatech.com 107777-01 1-866-672-6040 Rev. E 06/08