Краткое содержание страницы № 1 
                    
                        3-SIDED (PENINSULA), VENTED DECORATIVE GAS APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
MARBLEHEAD
NATURAL GAS MODELS GL36PN AND GL36PNE
PROPANE/LP GAS MODELS GL36PNP AND GL36PNEP
WARNING: If the information in these instructions is 
not followed exactly, a fire or explosion may result 
causing property damage, personal injury or death.
FOR YOUR SAFETY
— Do not store or use gasoline or any other flammable 
vapors or liquids in the vicinity of this or any other 
appliance.
— WHAT TO DO IF YO
                    
                    Краткое содержание страницы № 2 
                    
                        WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation  and operational procedures. For assistance or addi- tional information consult a qualified installer, service  agency or the gas supplier. NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATION SAVE THIS BOOK This book is valuable. In addition to instructing you on  how to install and maintain your appliance, it also co
                    
                    Краткое содержание страницы № 3 
                    
                        1. This appliance is only for use with the type  SAFETY INFORMATION of gas indicated on the rating plate. This ap- pliance is not convertible for use with other   WARNING: This product  gases. contains and/or generates  2. For propane/LP fireplace, do not place propane/ chemicals known to the State  LP supply tank(s) inside any structure. Locate  of California to cause cancer or  propane/LP supply tank(s) outdoors. To prevent  birth defects or other reproduc- performance problems, do not use prop
                    
                    Краткое содержание страницы № 4 
                    
                        16. Do not install fireplace directly on carpeting,  SAFETY INFORMATION vinyl tile or any combustible material other  Continued than wood. The fireplace must set on a metal  11. Keep the area around your fireplace clear of  or wood panel extending the full width and  combustible materials, gasoline and other  depth of the fireplace. flammable vapor and liquids. Do not run fire- 17. Do not use fireplace if any part has been ex- place where these are used or stored. Do not  posed to or under water. Immed
                    
                    Краткое содержание страницы № 5 
                    
                        This appliance complies with ANSI Z21.50B-1990  INTRODUCTION and CAM/CGA-2.22-M89 as a Vented Gas Ap- Models GL36PN/P and GL36PNE/P are decora- pliance and is listed and tested by the Omni Test  tive gas appliances that use a millivolt gas control  Laboratories. and piezo pilot or an electronic gas control valve  with an electronic ignition system respectively.   WARNING: Installation of  These systems require a 6", B-type venting system  this appliance should be done by  for operation. a qualifi
                    
                    Краткое содержание страницы № 6 
                    
                        1" Minimum SELECTING LOCATION 1" Minimum Clearance from Pipes Clearance to Combustibles to Combustibles Continued In selecting a location, the following precautions  3 22 / " 4 must be observed: 19" 1. Do not connect this appliance to a chimney  3 11 / " 8 system used for a solid fuel burning fire- place. 5 2. Install in an area providing ventilation and 21 / " 8 6" O.D. adequate combustion air. 4" Min. from the Perpendicular Side Wall to the Fireplace Opening (Typ.) 3. Due to high temperatures, 
                    
                    Краткое содержание страницы № 7 
                    
                        3 40 /8" FIREPLACE  1" Min. to Combustibles INSTALLATION Continued Nailing Flanges FRAMING Construct framing using dimensions shown if Figures  6, 7 and 8. (Use the figure applicable to your applica- Prepared Framing tion.) Figure 6 shows the framing dimensions prior  to having the appliance in place. If installing on a  platform, platform must be solid, flat and fully sup- Nails or Screws ported (see Figure 7). Once the unit has been fitted,  bring studs in against nailing flanges located on the  s
                    
                    Краткое содержание страницы № 8 
                    
                        T FIREPLACE   CAUTION: Do not connect  INSTALLATION this millivolt system wall switch  Continued to a regular 120v power source!  OPTIONAL OUTSIDE AIR KIT  Gas valve be damaged - will be (MODEL AK4) yond repair.  The installation of an outside air kit should be  completed during the rough framing of the fire- Wall Switch Installation place due to the nature of it's location. Outside  1. Remove the J-box cover plate from side of  combustion air is accessed through a vented  applianceʼs outer surro
                    
                    Краткое содержание страницы № 9 
                    
                        A E The gas control valve is secured to the burner pan  FIREPLACE  assembly underneath the front ledge. A 1/8" NPT  INSTALLATION plugged tapping is provided on the gas control  Continued valve for a test gauge connection immediately  upstream of the gas supply connection to the ap- pliance (see Figures 13 and 14). Pilot Gas Line Do Not Kink Pilot  To Pilot  Adjustment  Burner ON/OFF  Cap Knob To Main  Burner Strain Relief  Grommet Common  Ground Wire Inlet  Outlet  Pressure Pressure Figure 12 - 
                    
                    Краткое содержание страницы № 10 
                    
                        Shutoff  FIREPLACE  Key Valve INSTALLATION Continued To install: 1. Remove gas line cover plate from applianceʼs  outer surround at the location to be used. 2. Remove insulation from inside the gas line Extension conduit sleeve. 3. Run gas line through sleeve. Typical Exterior Wall Gas  4. Prepare incoming black iron gas line with  Shutoff Installation Teflon tape or pipe joint compound. (Check  Figure 15 - Typical Exterior Wall Gas  local codes as to the use of Teflon tape.) Shut-Off Installation
                    
                    Краткое содержание страницы № 11 
                    
                        FIREPLACE  Pilot Burner Ignitor Flame  INSTALLATION 1/8" to 1/4" Sensor  Continued 3/8" to 1/2" Noncombustible  Facing Material Pan  Burner Do Not  Block  Effective  Opening Figure 19 - Correct Pilot Flame Pattern  "L" Shaped Metal Support - Electronic Assembly Noncombustible Facing Material BURNER FLAME ADJUSTMENT The air shutter, located at the base of the main  burner tube, has been factory preset to the proper  air to bas ratio which results in a long, blue, cleaner  Figure 17 - Fireplace Fa
                    
                    Краткое содержание страницы № 12 
                    
                        Top Slot  FIREPLACE  Under Frame INSTALLATION Adjustment  Continued Clip OPTIONAL GLASS DOOR Adjustment  Glass doors are optional with this gas appliance (see Screw Replacement Parts and Accessories, page 19). Long Pivot Pin Installing Glass Door 1. Be sure top spring clip hole is aligned with  hole in fireplace frame (see Figure 21). Fit  glass door top pin into aligned holes. Bottom Pin 2. Swing inner end of bottom clip out away from  Bottom Slot fireplace frame. Fit door bottom pin into clip. A
                    
                    Краткое содержание страницы № 13 
                    
                        1. STOP! Read the safety information,  OPERATING FIREPLACE column 1. MILLIVOLT MODELS 2. Turn wall switch to the OFF position. 3. Turn off all electric power to the appliance. FOR YOUR SAFETY  4. Open control access panel. READ BEFORE LIGHTING 5. Push in gas  control knob and turn clock- wise  to the OFF position (see   WARNING: If you do not fol- Figure 23). Note: It is recommended that  low these instructions exactly,  you maintain the gas control knob in the  a fire or explosion may result  fu
                    
                    Краткое содержание страницы № 14 
                    
                        E A C. Use only your hand to push in or turn the     OPERATING FIREPLACE gas control knob. Never use tools. If the  Continued knob will not push in or turn by hand, donʼt  try to repair it, call a qualified service tech- TO TURN OFF GAS  nician or gas supplier. Force or attempted  TO APPLIANCE repair may result in a fire or explosion. 1. Turn off the wall switch. D. Do not use this appliance if any part has  2. Turn off all electric power to the appliance  been under water. Immediately call a  if 
                    
                    Краткое содержание страницы № 15 
                    
                        OPERATING FIREPLACE  WARNING: Turn off gas and  Continued electrical power before servicing  appliance. Any safety screen  or guard removed for servicing  must be replaced prior to operat- ing the appliance.  WARNING: Failure to keep  the primary air opening(s) of  the burner(s) clean may result in  Figure 26 - Pilot sooting and property damage. Keep control compartment, logs, burner and area  TO TURN OFF GAS  surrounding logs clean by vacuuming or brushing  TO APPLIANCE at least twice a year. T
                    
                    Краткое содержание страницы № 16 
                    
                        MV TH PV/MVTR GND PV IGN O WIRING DIAGRAMS PILOT THERMOPILE IGNITOR DO NOT CONNECT TO 120V N.C.SW HEAT LIMIT SWITCH TH TP TH/TP INCOMING MAIN GAS SUPPLY PILOT SAFETY WIRE WALL SWITCH (SUPPLIED) MILLIVOLT WIRING DIAGRAM PILOT INCOMING IGNITOR WALL SWITCH MAIN GAS (SUPPLIED) SUPPLY SENSOR BLACK INCOMING 120V AC WHITE (FUSE BOX GREEN OR BREAKER) N.C.SW HEAT LIMIT  EV1 SWITCH ELECTRICAL RATING: 120v, 60Hz, 0.7A EV2 24V AC STEP DOWN TRANSFORMER 120V AC OPTIONAL REMOTE GAS LINE CONTROL TO   BURNER ELE
                    
                    Краткое содержание страницы № 17 
                    
                        TROUBLESHOOTING MILLIVOLT SYSTEM Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.  The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot will not light 1. No gas supply or shutoff 1. Check to see if you have gas  valve is OFF supply 2. Air in gas line 2. Hold regulator control valve  in the PILOT position for 
                    
                    Краткое содержание страницы № 18 
                    
                        TROUBLESHOOTING ELECTRONIC IGNITION SYSTEM Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.  The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot will not light 1. No gas supply or shutoff 1. Check to see if you have gas  valve is OFF supply 2. Construction debris clog- 2. Remove debris and dirt, in- ging pil
                    
                    Краткое содержание страницы № 19 
                    
                        REPLACEMENT PARTS AND ACCESSORIES Purchase these fireplace replacement parts and BRUSHED BRASS CABINET STYLE  accessories from your local dealer. If they can not  DOOR KIT - DBBGL36PN supply these parts, call DESA at 1-866-672-6040  Right Panel Assy - 22367 for referral information. You can also write to the  Left Panel Assy - 22368 address listed on the back page of this manual. End Panel Assy - 22369 Before ordering, please have your applianceʼs  For use with all models. model name or number an
                    
                    Краткое содержание страницы № 20 
                    
                        LIMITED 2-YEAR WARRANTY DESA warrants this gas appliance to be free from the defects in material or workmanship at the time of manufacture. REMEDY AND EXCLUSIONS The coverage of this warranty is limited to all components of the gas appliance manufactured by DESA, with the  exception of glass and refractory. The glass is warranted for 90 days. There will be no cost for replacement of glass  within 90 days of installation, provided that breakage is due to heat from the appliance. We do not warrant