Краткое содержание страницы № 1 
                    
                        DO NOT
DISCARD
R
Owner’s Manual
Installation and Operation
Models:
QV32B-A
QV36B-A
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with 
and maintenance these instructions for safe 
party responsible for use 
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these 
HOT SURFACES! 
instructions is not followed exactly, a fi re 
Glass and other surfaces are hot during 
or explosion may re
                    
                    Краткое содержание страницы № 2 
                    
                        Read this manual before installing or operating this appliance.  Please retain this owner’s manual for future reference. This owner’s manual should be retained for future  A. Congratulations reference. We suggest that you keep it with your other  Congratulations on selecting a Quadra-Fire gas fi replace, an  important documents and product manuals. elegant and clean alternative to wood burning fi replaces. The  The information contained in this owner’s manual, unless  Quadra-Fire gas fi replace you
                    
                    Краткое содержание страницы № 3 
                    
                            Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Краткое содержание страницы № 4 
                    
                        13 Finishing   A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 52 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 14 Appliance Setup   A. Remove Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . 54 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 54 C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 D. Accessories . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Краткое содержание страницы № 5 
                    
                        B. Limited Lifetime Warranty Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for  HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership  of the appliance at the site of installation within
                    
                    Краткое содержание страницы № 6 
                    
                        B. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS:                                   WARRANTY EXCLUSIONS:                        -       -          -                               -   -    This warranty is void if:               LIMITATIONS OF LIABILITY:                                                    4021-645C 12-29-10 Page 2 of 2 6 Quadra-Fire  •  QV32B-A, QV36B-A  •  2014-900 Rev. U  •  1/12                                                                                         
                    
                    Краткое содержание страницы № 7 
                    
                        Listing and Code Approvals   1 1   A. Appliance Certifi cation C. BTU Specifi cations Maximum Minimum Orifi ce MODELS:  QV32B-A, QV36B-A Models Input Input  Size (DMS) U.S. (0-2000 ft.) or Canada (2000-4500 ft.) BTU/h BTU/h LABORATORY:  Underwriters Laboratories, Inc. (UL) US 28,000 17,000 38 QV32B-A (NG) TYPE:  Direct Vent Gas Fireplace Heater CANADA 25,200 15,300 39 STANDARD: ANSI Z21.88-2005 • CSA2.33-2005  US 26,300 15,000 1.55 mm QV32B-A (LP) CANADA 23,670 13,500 53 This product is listed to A
                    
                    Краткое содержание страницы № 8 
                    
                        Inspection Note: The following requirements reference various  The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this  tally vented gas fueled equipment shall not approve the  document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed  H. Requirements for the Commonwealth of  in accordance with the provisions of 248 CMR 5.08(2)(a)1  Massachusetts through 4.  For all side wall 
                    
                    Краткое содержание страницы № 9 
                    
                        User Guide Operating Instructions   2 2  • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether  operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES!  Glass and other surfaces are hot during  • Consider not using the fi replace when children will be  operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT to
                    
                    Краткое содержание страницы № 10 
                    
                        CLEAR SPACE  3 FT. IN FRONT OF FIREPLACE C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added.  Contact your dealer to See Section 14.G. order the correct fan kit. G. Remote Controls, Wall Controls and Wall  D. Clear Space Switches WARNING! DO NOT place combustible objects in front  Follow the instructions supplied with the control installed  of the fi replace or block louvers. High temperatures may  to operate your fi replace: start a fi re. See Figure 2.2. For safety: 
                    
                    Краткое содержание страницы № 11 
                    
                        I. Lighting Instructions (Standing Pilot) LIGHTING FOR YOUR SAFETY INSTRUCTIONS READ BEFORE LIGHTING 1. Open control access panel. WARNING: If you do not follow these instructions exactly, a fi re or explosion  2. Turn off all electric power to  may result causing property damage, personal injury or loss of life. the appliance. 3. Push in gas control knob  A. This appliance has a pilot which •   If you cannot reach your gas sup- slightly and turn clockwise  plier, call the fi re department. must b
                    
                    Краткое содержание страницы № 12 
                    
                        J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours  continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously  on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
                    
                    Краткое содержание страницы № 13 
                    
                        Maintenance and Service   3 3   Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be  replaced prior to operating the fi replace. Frequency: Annually By:  Homeowner When properly maintained, your fi replace will give you  many years of trouble-free service.  We recommend an- Tools needed:  Protective gloves, stable work surface nual service by a qualifi ed service technician.  • Assess condition of screen and replace as necessary.   A. Maintenance Tasks-Homeowner • Insp
                    
                    Краткое содержание страницы № 14 
                    
                        B. Maintenance Tasks-Qualifi ed Service Burner Ignition and Operation Technician Frequency: Annually The following tasks must be performed by a qualifi ed ser- By:  Qualifi ed Service Technician vice technician. Tools needed: Protective gloves, vacuum cleaner, whisk  Gasket Seal and Glass Assembly Inspection broom, fl ashlight, voltmeter, indexed drill bit set, and a  manometer. Frequency: Annually • Verify burner is properly secured and aligned with pilot  By:  Qualifi ed Service Technician or ignit
                    
                    Краткое содержание страницы № 15 
                    
                        Installer Guide Getting Started   4 4  A. Typical Appliance System NOTICE:  Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not  drawn to scale. Actual product may vary from pictures in manual HORIZONTAL  TERMINATION CAP  Note: Dual venting configurations  (SECTION 10.L) ARE NOT allowed. Appliance MUST  be vented EITHER vertically OR  horizontally. VERTICAL TERMINATION CAP  (SECTION 10.I) NON-COMBUSTIBLE ROOF FLASHING  MAINTAINS
                    
                    Краткое содержание страницы № 16 
                    
                        B. Design and Installation Considerations D. Inspect Appliance and Components Quadra-Fire direct vent gas appliances are designed to • Carefully remove the appliance and components from  operate with all combustion air siphoned from outside of the packaging.  the building and all exhaust gases expelled to the outside.  • The vent system components and decorative doors and  No additional outside air source is required. fronts may be shipped in separate packages.  Installation MUST comply with loc
                    
                    Краткое содержание страницы № 17 
                    
                        Framing and Clearances   5 5   NOTICE: Illustrations refl ect typical installations and are  A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams  When selecting a location for the appliance it is important to  are not drawn to scale. Actual installation may vary due to  consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate  clearance around air openings and for service access.  Due to
                    
                    Краткое содержание страницы № 18 
                    
                        fi restops should be caulked with caulk with a minimum of  B. Constructing the Appliance Chase 300ºF continuous exposure rating to seal gaps. Gas line  A chase is a vertical box-like structure built to enclose the  holes and other openings should be caulked with caulk  gas appliance and/or its vent system. In cooler climates  with a minimum of 300ºF continuous exposure rating or  the vent should be enclosed inside the chase. stuffed with unfaced insulation. If the appliance is being in- NOTICE: T
                    
                    Краткое содержание страницы № 19 
                    
                        D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specifi ed. Framing or fi nishing material closer than  the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc). 3 IN.  TOP VIEW MINIMUM Combustible Mantels 5-3/8 IN.  All measurements are in inches. CEILING MINIMUM UNLIMITED Note: Clearance from opening  to perpendicular wall. 12 11 10 Figure 5.5  Wall Projection (Acceptable on one side of o
                    
                    Краткое содержание страницы № 20 
                    
                        Termination Locations   6 6  A. Vent Termination Minimum Clearances AB 6 in. (minimum) up to 20 in. 18 in. minimum 152 mm/508 mm 457 mm WARNING 20 in. and over 0 in. minimum Fire Risk. Gas, Wood or Fuel Oil Maintain vent clearance to combustibles as  Termination Cap specifi ed. • DO NOT pack air space with insulation or other  materials. B Failure to keep insulation or other materials away  from vent pipe may cause overheating and fi re. A * HORIZONTAL Gas OVERHANG Termination Cap ** 2 FT. 20 INCH