MODELS:   E21-NG1 Natural Gas   E21-LP1 Propane
WARNING:  FOR YOUR SAFETY
If the information in these instructions are not followed exactly, What to do if you smell gas:
a fi re or explosion may result causing property damage, Do not try to light any appliance
personal injury or loss of life. Do not touch any electrical switch: 
do not use any phone in your 
FOR YOUR SAFETY
building.
Do not store or use gasoline or other fl ammable 
                    
                    Краткое содержание страницы № 2 
                    
                        CONGRATULATIONS! You are the owner of a state-of-the-art Gas Insert by: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency Gas Fireplace Series has been designed to provide you with all  the warmth and charm  of a fi replace, at the fl ick of a switch.  The models E21-NG1 and E21-LP1 of this series have been  approved by Warnock Hersey for safety.  As it also bears our own mark, it promises to provide you with  economy, comfort and security for many trouble free years to follow.  Please take a 
                    
                    Краткое содержание страницы № 3 
                    
                        TABLE OF CONTENTS E21 GAS INSERT       Page           Page OPERATING INSTRUCTIONS SAFETY LABEL Operating Instructions .................................................20 Safety Label ..................................................................4 Lighting Procedure ......................................................20 Shutdown Procedure ...................................................20 First Fire ......................................................................20 INSTALLATION INS
                    
                    Краткое содержание страницы № 4 
                    
                        SAFETY LABEL This is a copy of the label that accompanies  Note: Regency units are constantly being  each Regency Gas Insert. We have printed  improved. Check the label on the unit  a copy of the contents here for your review.  and if there is a difference, the label  The safety label is located on the front inside  on the unit is the correct one.  base of the unit visible when the bottom louver  is open.   Please note that with the addition  of thermostat control and outside  combustion air sup
                    
                    Краткое содержание страницы № 5 
                    
                        INSTALLATION  11) To prevent injury, do not allow anyone who  IMPORTANT:   YOUNG CHILDREN SHOULD BE  is unfamiliar with the operation to use the  CAREFULLY  SUPERVISED WHEN  SAVE THESE  fi replace insert. THEY ARE IN THE SAME ROOM  INSTRUCTIONS AS THE APPLIANCE. 12) Wear gloves and safety glasses for protection  while doing required maintenance. The Regency Gas Fireplace must be installed  C L O T H I N G O R O T H E R  in accordance with these instructions. Carefully 13) Ensure adequate combusti
                    
                    Краткое содержание страницы № 6 
                    
                        INSTALLATION  POLICY FOR SOLID INSTALLATION MINIMUM FIREPLACE  FUEL BURNING & CHECKLIST CLEARANCES FACTORY BUILT  1) Locate appliance, check Clearances to Diagram shows the minimum fi replace opening  Combustibles, page 7. required to be able to install the Regency gas  FIREPLACES fi replace insert. 2) Make gas and electrical connections, page   The Regency E21 may be installed and vented  8. Test the pilot. Must be as per diagram,  into any solid fuel fi replace that has been installed  page 11. i
                    
                    Краткое содержание страницы № 7 
                    
                        INSTALLATION  CLEARANCES TO  COMBUSTIBLES The minimum clearance from the side of the appliance to a combustible Note: A non-combustible mantel may be installed at a lower height  side wall is 9 inches (229mm). The minimum clearance from the top of if the framing is made of metal studs covered with a non- the louver to a combustible mantel is 14 14 inches inches (356mm) (356mm). The minimum combustible board. height from the top of the louver to the ceiling is 36 36 inches inches (914mm) (914mm).
                    
                    Краткое содержание страницы № 8 
                    
                        INSTALLATION For minimum and maximum supply pressure  GAS CONNECTION System Data see the System Data table. Only persons licensed to work with gas piping  For altitude: Natural Gas 0-2000 ft.    1) If the appliance is to be installed into an  may make the necessary gas connections to    Propane: 0-4500 ft. existing chimney system, thoroughly clean  this appliance.   the masonry fi replace that has been chosen  for the Regency Gas Fireplace. Burner Inlet Orifi ce Sizes: The gas connection is a 3/8"
                    
                    Краткое содержание страницы № 9 
                    
                        O L Black N O INSTALLATION WIRING DIAGRAM FOR THE E21-NG1 AND E21-LP1 This heater does not require a 120V A.C. supply codes the current CSA C22.1 (in Canada) or  Caution: Ensure that the wires do  for operation. In case of a power failure, the with the National Electrical Code ANSI/NFPA  not touch any hot surfaces and are  burner switch and the optional remote control/ 70-1987 (in USA).  away from sharp edges. thermostat will continue to operate. However,  a 120V A.C. power supply is needed for 
                    
                    Краткое содержание страницы № 10 
                    
                        INSTALLATION B-Vent chimneys require a 1" clearance to  OFFSET FLUE COMBUSTION AND  combustibles. ADAPTOR VENTILATION AIR A 3" diameter type B-Vent or approved aluminium  fl ex liner may also be used with a 4" to 3" reduc- A Offset Flue Adaptor Kit, Part #532-920 is WARNING:  This appliance needs fresh air  ing adapter. Consult venting charts and local  available as an accessory to move the fl ue for safe operation and must be installed  code requirements. outlet back for easier liner installation
                    
                    Краткое содержание страницы № 11 
                    
                        INSTALLATION a scrap piece of sheet metal (or other  Valve Description GAS INSERT AERATION  noncombustible material) in the upper louver,  this will prevent the natural convection of the  SYSTEM 1) Gas cock knob unit from interfering with the test. 2) Manual high/low adjustment The aeration adjustment rod is attached to the  Note: The smoke should be drawn into the  3) Pilot Adjustment air shutter which is located just above the orifi ce  louver. If the smoke is still not drawn  bracket. The rod 
                    
                    Краткое содержание страницы № 12 
                    
                        INSTALLATION 4) Place the Front Left Log B) 02-67 on the 2  LOG SET  front pins. INSTALLATION Read the instructions below carefully and  refer to the diagrams.  If logs are broken  do not use the unit until they are replaced.  Broken logs can  interfere with the pilot  operation. The gas log kit (set# 532-930) contains  the following: a) 02-66 Rear Log   b) 02-67 Front Left Log  c) 02-68 Middle Left Log  d) 02-70 Middle Right Log  e) 02-69 Front Right Log  Cutout   f)  Embers   5) Place the Midd
                    
                    Краткое содержание страницы № 13 
                    
                        INSTALLATION 7) Tuck the wires into the faceplate to keep  FLUSH  GLASS them away from the insert using the clip  provided.  Attach the clip to the rear of the  faceplate to ensure that the wires do not 1) Install the bottom glass trim onto the glass  touch the side of the unit.  See diagram 3. support. 2) Slide the glass into the bottom glass trim  and secure with the glass clips using the 2  phillips head screws at the top. 3) Slide the top glass trim by sliding under the  two spring clips. No
                    
                    Краткое содержание страницы № 14 
                    
                        INSTALLATION FLUSH LOUVERS OPTIONAL BAY FRONT BAY LOUVERS 1) Install top louver by sliding the two bracket  IMPORTANT  1) The Top Louver is held in place by Spring  clips into the brackets located on top of the   Flush glass must stay in place  Clips. Push into place as shown. bay door. See below. The fi tted louver leaves  when bay option is used. The bay  a small gap between faceplate bottom and  louver top. front is a decorative overlay only.  1) Place the bay door onto the 2 pins on the  top 
                    
                    Краткое содержание страницы № 15 
                    
                        INSTALLATION Conversion Kit from Natural Gas to Propane Model #533-969  THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Turn the unit off and allow it to cool to room temperature. 8) Pull off the pilot cap to expose the pilot orifi ce. 2) Shut off gass supply 9) Unscrew the pilot  orifi ce with the allen key (provided) and replace  3) Unplug or disconnect power source to stove. with the LP pilot orifi ce in the kit. 4) Remove glass front (see manua
                    
                    Краткое содержание страницы № 16 
                    
                        INSTALLATION 16) Attach clear label "This unit has been converted to Propane" near or  11) Remove and discard the 3 pressure regulator mounting screws (A),  on the serial # decal. Attach white label "This valve has been converted  pressure regulator tower (B) and diaphragm (C). from NG to LPG using SIT conversion Kit  Code 0.907.202" onto the  valve. 12) Insure that the rubber gasket (D) is properly positioned and install  the new HI/LO pressure regulator assembly to the valve using the  new scr
                    
                    Краткое содержание страницы № 17 
                    
                        INSTALLATION FULL SCREEN FRONT 1) Hold the full screen door up against the unit in order to make the 3) Completely secure full screen door to the unit by securing 4 screws  following wire connections. to the Left and Right Side Trim.  Pull the ON/OFF connector wires thru the box and connect them to  the switch.  Connect the fan switch wires with the wire connectors from the fan  speed control. Place clips over wires and tuck into side trim.  4) Secure the Top Frame by sliding it on the screws at
                    
                    Краткое содержание страницы № 18 
                    
                        INSTALLATION 7) Install the Left and Right Side Screen Doors by placing over top of  5) Install Spring Hinges to the Left and Right Side of the bottom of the  fi rebox using 2 screws per hinge. the hinges on the faceplate.  Hold the door at a 45 degree angle to avoid scratching the  faceplate. Hinge 6) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and  secure with 3 screws each. Screen Door Hinge Location Bottom Frame 8) Close screen doors. 18 Regency E21 Gas Fireplace Insert       
                    
                    Краткое содержание страницы № 19 
                    
                        I H T O L PI F F O T o thermopile INSTALLATION Option 1:  Option 2: Option 3:  REMOTE CONTROL WALL SWITCH WALL THERMOSTAT  Use the Regency Remote Control Kit  approved 1) Run the wire through the right or left side  A wall thermostat may be installed if desired,  for this unit. Use of other systems may void inlet opening. Be careful not to damage the  connect the wires as per the wiring diagram.  your warranty. wire. Use table below to determine the maximum  wire length. The remote control kit c
                    
                    Краткое содержание страницы № 20 
                    
                        OPERATING INSTRUCTIONS 6) Verify log placement. If the pilot cannot be 7) Turn gas control knob counter clockwise to  FINAL CHECK "ON". seen when lighting the unit - the logs or the  embers have been incorrectly positioned. Before leaving this unit with the customer, the  8) Use the rocker switch to operate main  installer must ensure that the appliance is fi ring  burner. 7) The unit should never be turned off and on  correctly. This includes: again without a minimum of a 60 second  9) Rotate th