Краткое содержание страницы № 1 
                    
                        Owners & 
™ 
U32 Sunrise Gas Insert
Installation Manual
MODELS: U32S-NG5 Natural Gas   
       U32S-LP5 Propane
www.regency-fi re.com
WARNING:  FOR YOUR SAFETY
Improper installation, adjustment, alteration, service or What to do if you smell gas:
maintenance can cause injury or property damage. Refer to  Do not try to light any appliance
this manual. For assistance or additional information consult  Do not touch any electrical switch: 
an authorized installer, service agency or the gas supplier. 
                    
                    Краткое содержание страницы № 2 
                    
                        TO THE NEW OWNER Congratulations!  You are the owner of a state-of-the-art Gas Insert by FPI. The U32 Sunrise Gas Insert has been  designed to provide you with all  the warmth and charm of a fi replace,  at the fl ick of a switch.  The U32S-NG5 and U32S-LP5 have been approved by Warnock Hersey/Intertek for  both safety and effi ciency.  As it also bears our own mark, it promises to provide you with economy, comfort  and security for many trouble free years to follow.   Please take a moment now to a
                    
                    Краткое содержание страницы № 3 
                    
                        TABLE OF CONTENTS OPERATING INSTRUCTIONS SAFETY LABEL Safety Label...................................................................4 Operating Instructions  ................................................22 Lighting Procedure ......................................................22 Shutdown Procedure ...................................................22 REQUIREMENTS  First Fire ......................................................................22 Automatic Convection Fan Operation.........
                    
                    Краткое содержание страницы № 4 
                    
                        SAFETY LABEL This is a copy of the label that accompanies each U32S-5 Gas Insert. NOTE: FPI units are constantly being improved. Check the label  We have printed a copy of the contents here for your review. The safety on the unit and if there is a difference, the label on the unit is the  label is located on a plate inside the base of the unit visible when the correct one. bottom louver is opened. For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter lice
                    
                    Краткое содержание страницы № 5 
                    
                        REQUIREMENTS  MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements:  (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  seven (7) feet above finished gr
                    
                    Краткое содержание страницы № 6 
                    
                        UNIT DIMENSIONS 6 U32S-5 FPI Direct Vent Gas Insert                                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Краткое содержание страницы № 7 
                    
                        INSTALLATION General Safety Information IMPORTANT MESSAGE  GAS PRESSURE  TESTING 1) The appliance installation must conform  SAVE THESE  with local codes or in the absence of local  INSTRUCTIONS codes, with CAN/CGA B149 (in Canada) or  The appliance must be isolated from the gas  the National Fuel Gas Code ANSI Z223.1 in  supply piping system by closing its individual  The FPI Gas Insert must be installed in   the U.S.A. This appliance should be installed  manual shut off valve during any pressu
                    
                    Краткое содержание страницы № 8 
                    
                        INSTALLATION   INSTALLATION CLEARANCES TO  MANUFACTURED  CHECKLIST COMBUSTIBLES MOBILE HOME  ADDITIONAL  Before installing vent system ensure that the Minimum Clearances to Combustibles damper plate is open and secure to prevent the  REQUIREMENTS damper plate from falling down and crushing                              From Unit             the liner. Sides A 10" / 255 mm 1) Ensure that structural members are not cut  Ceiling B 47.5" / 1205 mm or weakened during installation. The FPI Gas Insert i
                    
                    Краткое содержание страницы № 9 
                    
                        INSTALLATION GAS CONNECTION  COMBUSTIBLE MANTEL  CLEARANCES GAS CONNECTION WARNING: G Only persons licensed to work  12 10 8 6 4 2 with gas piping may make the  necessary gas connections  18 to this appliance.   12" Mantel 16 47” 1) If the appliance is to be installed into an  (1194mm) 3-1/2" existing chimney system, thoroughly clean  to ceiling 14 Mantel the masonry or factory built fi replace. 12 2) The appliance is provided with an opening on  10 the left hand side of the control compartment. 
                    
                    Краткое содержание страницы № 10 
                    
                        INSTALLATION  5) The pressure check should be carried out  with the unit burning and the setting should  FLUE LINER  be within the limits specifi ed on the safety  label. INSTALLATION 6) When fi nished reading manometer, turn  1) Cut the fl ex liner as required. off the gas valve, disconnect the hose and    tighten the screw (clockwise) with a 1/8"  2) Mark the end of one liner to indicate  fl at screwdriver. Note: Screw should be  Inlet. snug, but do not over tighten. 3) Connect the other end of th
                    
                    Краткое содержание страницы № 11 
                    
                        INSTALLATION  CONVERSION KIT # 434-969 FROM NG TO LP   U32S-5 using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!  b)  Swing the door out 45 degrees from  Each Kit contains one LP  the bottom  and lift up and out. Conversion Kit and one DC Sparker Kit. 3) Remove the burner by undoing the 2  LP Conversion Kit Contains: screws as shown below.  Qty. Part # Description          1 904-163 Burner Orifi ce #54 1 918-590 Decal "Conv
                    
                    Краткое содержание страницы № 12 
                    
                        INSTALLATION 15) Insert a 5/32” or 4mm Allen wrench into  WARNING! the hexagonal key-way of the screw  (Fig. 2), rotate it counter-clockwise until  Do not overtighten the screw.  it is free and extract it. Recommended to grip the wrench by the short side. 19) Verify that if the conversion is from  Pilot Cap NG to LPG, the screw  must be re- assembled with the red o-ring visible  9) Pull off the pilot cap to expose the pilot (Fig. 5).  orifi ce. LPG Configuration Red o-ring visible Fig.5  20) Re-a
                    
                    Краткое содержание страницы № 13 
                    
                        INSTALLATION  11) Install the supplied battery into the DC  6) Connect one end of the supplied green  Installation of the DC Sparker Sparker Box by opening the battery  ground wire to the lug with the nut and  compartment. washer from the kit.  1) Locate the Piezo Ignitor situated at the   NOTE: The battery in the DC Sparker  side of valve. Box will need to be replaced annually. Ground  wire from  kit Battery Piezo ignitor Compartment  2) Remove the Piezo Ignitor by unscrewing  7) Install the 1/
                    
                    Краткое содержание страницы № 14 
                    
                        INSTALLATION OPTIONAL WALL THERMOSTAT  FINAL CHECK A wall thermostat may be installed if desired, follow the wiring diagram  Before leaving this unit with the customer, the installer must ensure that  below. FPI offers an optional programmable thermostat but any 250- the appliance is fi ring correctly. This includes: 750 millivolt rated non-anticipator type thermostat that is CSA, ULC or  UL approved may be used. 1) Clocking the appliance to ensure the correct fi ring rate (rate noted  on label) a
                    
                    Краткое содержание страницы № 15 
                    
                        O L Black Regency N O INSTALLATION  WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/  thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes Green Fan Ground Neutral Ground Live 
                    
                    Краткое содержание страницы № 16 
                    
                        INSTALLATION  For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. 16 U32S-5 FPI Direct Vent Gas Insert                                                                                                                                                                                                                                                                                                          
                    
                    Краткое содержание страницы № 17 
                    
                        INSTALLATION  GLASS CRYSTAL OR OPTIONAL CERAMIC STONES INSTALLATION ON BURNER  Spread the supplied Glass Crystals (or optional Ceramic  Spa Stones) evenly over the burner. Ensure the crystals (or  stones) do not overlap too much as this will effect the fl ame  pattern. NOTE: When installing, use either the supplied Glass Crystals or  optional Ceramic Spa Stones - DO NOT combine the two.  Only  Burner shown with Glass Crystals the supplied approved Cobalt Blue Glass or optional 70 pieces  of Ceram
                    
                    Краткое содержание страницы № 18 
                    
                        INSTALLATION STANDARD To remove the fl ush door, reverse the above steps. FLUSH DOOR IMPORTANT NOTE: The chain must rest on TOP of the gas inlet  pipe never under it. The standard fl ush door comes with a black frame. To install the frame,  simply hook the top door fl ange onto the top of the unit and swing the  door towards the unit, diagram 1. Be careful that the glass gasket does  not roll up; there must be a gap between the gasket and the door lip to  ensure that the door sits securely on the u
                    
                    Краткое содержание страницы № 19 
                    
                        INSTALLATION  FACEPLATE AND DOOR FRAME INSTALLATION Kit# 425-914 Contents List: Note:  Ensure that the fl anges on the sides of the fi rebox are on the                  outside, when installing the faceplate (see below). 1 Complete Faceplate with Switches 1 Door Frame 1 Bottom Louver 2 Hinges 2              Bottom Louver Brackets 4 Pan Head Screws Faceplate 1 Wire Clip 1 Instruction Sheet Flange on fi rebox 1) Bring the faceplate up in front of the unit and connect the red &  black ON/OFF wires fro
                    
                    Краткое содержание страницы № 20 
                    
                        INSTALLATION  7) Install the door frame by hooking the top fl ange over the top of the  glass door. 8)  Lower the door frame gently into place. 9)  Run supplied 120V power cord along front face of masonry fi replace and plug into nearest receptacle. 10)  Slide unit into fi nal position. Completed Faceplate & Door Frame Installation 20 U32S-5 FPI Direct Vent Gas Insert