                        INSTALLATION INSTRUCTIONS
SSDV Direct-Vent 
Gas Fireplaces
P/N 700031M   Rev. F   01/2011 
This manual is one of a set of two supporting this product.  
MODELS
Refer to P/N 725035M for Care and Operation Instructions.
MILLIVOLT: ELECTRONIC:
Ce manuel est disponible en francais, simplement  
SSDVST-CNM-B      SSDVST-CNE-B
en faire la demande. Numéro de la pièce 700031CF.
SSDVPF-CNM-B      SSDVPF-CNE-B
Portland
US
OTL Report No. 116-F-32-5
INSTALLER: Leave this manual with the appliance.
CONSUMER:
                    
                    Краткое содержание страницы № 2 
                    
                        PACKAGING GENERAL INFORMATION TABLE OF CONTENTS  Packaging .........................................Page 2 The  assembled vented gas fireplace heater  is  packaged with: Introduction ......................................Page 2        WARNING  1 -  One log set located in firebox area. General Information ..........................Page 2 2 -  One envelope containing the literature  Young children should be care- Requirements for the  package, located in the firebox which  fully supervised when th
                    
                    Краткое содержание страницы № 3 
                    
                        The appliance, when installed, must be electri- Note: Installation and repair should be done  cally grounded and wired in accordance with         WARNING by a qualified service person. The appliance  local codes or, in the absence of local codes,  should be inspected before use and at least  with the National Electrical Code, ANSI/NFPA  Improper installation, adjust- annually by a professional service person.  70 - latest edition, or the Canadian Electrical  ment, alteration, service or More fre
                    
                    Краткое содержание страницы № 4 
                    
                        O I O L I P T O IGNITER OFF ON CONTROL it TPTH TP TH L I P F LO F Gas Pressure - All Models Orifice Sizes -  Sea Level to High Altitude ON / OFF Switch (All Models) Manifold Pressure  Tables 3 and 4  show the appliances' gas  Port Inlet  These appliances are tested and approved for  pressure requirements: Pressure installation at elevations of 0-4500 feet (0-1372  Port meters) above sea level using the standard  Inlet Gas Supply Pressure burner orifice sizes (marked with an "*" in Table  (all mo
                    
                    Краткое содержание страницы № 5 
                    
                        COLD CLIMATE INSULATION For cold climate installations, seal all cracks  around your appliance with noncombustible  material and wherever cold air could enter  the room. It is especially important to insulate  outside chase cavity between studs and under  floor on which appliance rests, if floor is above  ground level.  Gas line holes and other open- Offset Venting Vertical ings should be caulked or stuffed with unfaced  (one end flush Venting with wall) fiberglass insulation.   If the fireplace
                    
                    Краткое содержание страницы № 6 
                    
                        VENT TERMINATION CLEARANCES Vertical Vent Termination  Clearances Termination Heights For Vents  These instructions should be used as a  TERMINATION HEIGHTS FOR VENTS ABOVE Above Flat Or Sloped Roofs guideline and do not supersede local codes  FLAT OR SLOPED ROOFS  Ref. NFPA 54 / ANSI Z223.1 Horizontal Overhang  in any way. Install venting according to local  Roof Pitch * Feet * Meters codes, these instructions, the current National  2 FT  Vertical  MIN.  Fuel Gas Code (ANSI-Z223.1) in the USA o
                    
                    Краткое содержание страницы № 7 
                    
                        V EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS  NOTE:  Local Codes Or Regulations May Require Different Clearances. * See Item D in the Text Below. N P N NOTE:  Location Of The Vent Termination Exterior Wall Inside Must Not Interfere With Access To The Corner Detail O Electrical Service. *18” V V G Q Horizontal Termination V 6” Ventilated Soffit A Inside Corner = 9” in U.S. � A = 12” in Canada Detail D H 3 ft. B B D E X C � A � A V V L Fixed Operable V Closed Window 3 ft. Window V
                    
                    Краткое содержание страницы № 8 
                    
                        MINIMUM CLEARANCES TO COMBUSTIBLES Appliance and Vent Clearances Maintain clearances from appliance to  Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is used,  combustible materials as detailed in Table  do not block the lower control compartment access door. Any hearth extension used is for appearance  6, with the following exception: When the  only and does not have to conform to standard hearth extension installation requirements. appliance i
                    
                    Краткое содержание страницы № 9 
                    
                        Step 1. FRAMING TYPICAL INSTALLATION SEQUENCE        WARNING  Frame these appliances as illustrated in Figures  The typical sequence of installation is outlined  Failure to position the parts in  12 and 13 on Pages 10 and 11.  All framing  below.  However, each installation is unique  accordance with these diagrams  details must allow for a minimum clearance to  and may result in variations to the steps  or failure to use only parts specifi- combustible framing members as shown in  described.  c
                    
                    Краткое содержание страницы № 10 
                    
                        FIREPLACE SPECIFICATIONS - SSDVST (SEE-THROUGH) • Inches (millimeters) SPECIFICATIONS • Minimum Framing Stud Size is 2 x 4 • See side views of fireplace below for  Natural and Propane 37,500     gas line inlet location options. (MV Low 30,000) Gas BTU Input **25-1/4 11-3/8 (641) (289) 4-1/2" Inner  10-1/2 Co-axial DV Vent Size Vent Framing -  7-1/2" Outer (267) Dimension A Top Vent With  Vent Center - Top  Secure Vent 47-1/8 (1194) Vent with one 90  One 90º  Elbow 10-1/2 Secure Flex 47-7/8 (1216
                    
                    Краткое содержание страницы № 11 
                    
                        FIREPLACE SPECIFICATIONS - SSDVPF (PENINSULA VIEW) Fireplace Framing Specifications • Inches (millimeters) SPECIFICATIONS • Minimum Framing Stud Size is 2 x 4 • See right side viewsof fireplace below for gas line inlet location options. Natural & Propane 37,500 inches (millimeters) **25-1/4 11-3/8 (MV Low 30,000) Gas BTU Input (641) Minimum Framing Stud Size is 2 x 4 10-1/2 Dimension A 4-1/2" Inner (267) Co-axial DV Vent Size Vent Center - Top Secure Vent 47-1/8 (1194) Vent Framing - Top Vent  7
                    
                    Краткое содержание страницы № 12 
                    
                        Step 2. ROUTING GAS LINE Proper Sizing of Gas Line Notes: • All appliances are factory-equipped with a  Properly size and route the gas supply line  Route a gas line along the inside of the right flexible gas line connector and 1/2 inch shutoff  from the supply regulator to the area where  side framing as shown in Figure 14.  Gas valve (see Figure 47 on Page 27). the appliance is to be installed per require- lines must be routed, constructed and made • See Massachusetts Requirements on Page  men
                    
                    Краткое содержание страницы № 13 
                    
                        Step 3. INSTALL THE VENT SYSTEM  Vent Seal Cap Insulation General Information These instructions should be used as a guideline and do not supersede  local codes in any way. Install venting according to local codes, these  instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the  USA or the current standards of CAN/CSA-B149.1 in Canada.  CROSS SECTION (INSIDE of (OUTSIDE of  Ensure clearances are in accordance with local installation codes and  Appliance) Appliance) the requirements 
                    
                    Краткое содержание страницы № 14 
                    
                        VERTICAL TERMINATION SYSTEMS (ROOF) VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART T Nominal 6 12 24 36 48 Nominal Section 6 12 24 36 48 VENT SECTION LENGTH CHART See Figure 18 and Figures 27 to 31 (Pages 17 T O Length (inches) Section Length  O T Nominal Section and 18) and their associated Vertical Vent Tables T VENT SECTION LENGTH CHART 6 12 24 36 48 (inches) T O Length (inches) A Net Section 4 ½ 10 ½ 22 ½ 34 ½ 46 ½ Nominal illustrate the vertical venting configurations that T T A Net Se
                    
                    Краткое содержание страницы № 15 
                    
                        Vertical (offset) Installation D. Install firestop / spacer at ceiling - When  B. Attach vent components to appliance - Se- cure Vent  SV4.5 direct-vent system compo- using Secure Vent, use SV4.5VF firestop /  Analyze the vent routing and determine the  nents are unitized concentric pipe components spacer at ceiling joists; when using Secure  number of vent sections and elbows required.  featuring positive twist lock connections (see Flex, use SF4.5VF firestop / spacer. If there is  Refer to Ver
                    
                    Краткое содержание страницы № 16 
                    
                        Use a carpenter’s level to measure from a  SV4.5CGV-1 SV4.5FA or constant surface and adjust the support straps  Termination SV4.5FB Flashing Storm as necessary.  and SV4.5SC  Collar Storm Collar It is important to maintain the required clear- 1” (25.4 mm) ances to combustibles: 1" (25 mm) at all sides  vWhen using  Minimum  for all vertical runs; and 3" (76 mm) at the top,  secure Flex, use  Clearance to 1" (25 mm) at sides, and 1" (25 mm) at the  Firestop/Spacer  Combustibles bottom for all ho
                    
                    Краткое содержание страницы № 17 
                    
                        VERTICAL VENT FIGURES/TABLES      Table A u When using Secure Flex, use Firestop  Notes:  V Minimum / Spacer SF4.5VF H Maximum  •	 Secure  Vent™  (rigid vent pipe)  is shown  in the Figures; Secure Flex™ (flexible vent feet (meter) feet (meter) pipe) may also be used. 2 (0.610) 1 (0.305) •	 It	 is	 ver y	 important	 that	 the	 horizontal/ inclined run be maintained in a straight (no 4 (1.219) 2 (0.610) dips) and recommended to be in a slightly  u Ceiling Firestop / Spacer (SV4.5VF) 6 (1.829) 3 (
                    
                    Краткое содержание страницы № 18 
                    
                        VERTICAL VENT FIGURES / TABLES (CONTINUED) Table C H1 H+H Maximum H Maximum V Minimum 1    feet (meter) feet (meter) feet (meter) u Ceiling  Firestop / Spacer  5 (1.524) 2 (0.610) 1 (0.305) (SV4.5VF) 10 (3.048) 4 (1.219) 2 (0.610) 15 (4.572) 6 (1.829) 3 (0.914) 20 (6.096) 8 (2.438) 4 (1.219) Wall Firestop/ v V + V + H + H = 40 feet (12.2 m) Max 1 1 Spacer (SV4.5HF) H = 8 feet (2.438 meters) Max. V1 H + H = 20 feet (6.096 meters) Max. u Ceiling Firestop /  1   Spacer (SV4.5VF) u When using Secure
                    
                    Краткое содержание страницы № 19 
                    
                        Push the vent component against the previous  Support Horizontal / Inclined Run Building section until it fully engages, then twist the  Brackets Support component clockwise running the dimples  Framing down and along the incline channels until they  SV4.5HT-2 SV4.5E90 seat at the end of the channels.  This seating  Termination Elbow Shown position is indicated by the alignment of the  arrow and dimple as shown in Figure 20 on  Page 15. SV4.5L6/12/24/36/48 Vent Sections Exterior  Firestop / Spac
                    
                    Краткое содержание страницы № 20 
                    
                        J. Assemble vent run to exterior wall - If not  previously measured, locate the center of the  To help minimize water infiltration it is recommended that the Firestop/Spacer vent at the exterior wall.  Prepare an opening  (SV4.5HF) be installed on the exterior as described in Step B.  Assemble the vent  side of the wall. system to point where the terminus of the last SV4.5 HT-2 Termination section is located relative to the exterior surface  7" (178) to which the termination is to be attached as