Краткое содержание страницы № 1 
                    
                        Installation & Operating manual
The harman SF 250 Coal Stove
r3
SAFETY NOTICE
PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr.  F AIlurE 
TO FOllOw INSTruCTIONS mAY rESul T IN PrOPErTY dAmAgE, bOdIl Y INjur Y, Or EvEN dEATh.
FOr uSE IN ThE u.S. ANd CANAdA.  NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES
IF ThIS hArmAN STOvE IS NOT PrOPErl Y INSTAllEd, A hOuSE FIrE mAY rESul T.  FOr YOur SAFETY, FOl -
lOw INSTAllATION dIrECTIONS.  
CONTACT lOCAl buIldINg Or FIrE OFFI
                    
                    Краткое содержание страницы № 2 
                    
                        TAblE OF CONTENTS Safety Considerations..........................3 Assembly..............................................4 Installation............................................5 Chimney & Venting...............................6 Operating Instructions..........................8 Preventive Maintenance.......................9 Optional Hot Water Coil.......................0 Testing Label....................................... Warranty..............................................3           
                    
                    Краткое содержание страницы № 3 
                    
                        SAFETY CONSIdErATIONS CAuTION Curing Paint During the first few hours of burning, a blue smoke  l  Keep Children Away will be observed rising from the painted surface of the  l  may Cause Serious burns stove. It is advisable to increase the amount of fresh  l  All Surfaces of stove are hot. do not touch.  air (open window) in the room during this breaking-in  l  Keep children away.  period. Do not be alarmed, this is normal and does not  l  Serious burns will result if touched.  cause harm. mobi
                    
                    Краткое содержание страницы № 4 
                    
                        ASSEmbl Y blower  The blower slides into the channel bracket on the rear  of the stove as shown at right. Plug the blower into a  properly grounded receptacle. Shaker handle The shaker handle installs onto the shaker handle  mount using the two hex-bolts and washers provided.  Firebricks The SF250 uses 14 “standard” firebricks, as shown  below. These standard firebricks measure 9” X 4½”  X 1¼” each. The firebricks are already installed in  the stove but can be removed to lighten the stove for  m
                    
                    Краткое содержание страницы № 5 
                    
                        INSTAllATION wArNINg: This stove must be installed in accor- Adjustable leveling Feet dance with all state and local building code require- To accomodate an un-even hearth surface, the SF250  ments. is equipped with adjustable leveling feet. Each foot  can be turned in or out of the leg to lower or raise that  locating the stove corner of the stove. Locate the stove as close to the chimney or flue as  possible, while still maintaining the clearances to com- bustibles. Locate the stove where ther
                    
                    Краткое содержание страницы № 6 
                    
                        ChImNEY & vENTINg Types Of Chimneys The chimney is one of the most important, yet most  neglected and misunderstood portions of any solid  fuel burning stove installation. Do not connect this  stove to a chimney flue serving another heating de- vice. THE STOVE MUST BE CONNECTED TO ITS OWN  TILE-LINED FLUE. A MINIMUM FLUE SIZE OF 8” X  8” IS NECESSARY FOR PROPER OPERATION. UNDER NO CIRCUMSTANCES SHOULD A MANUAL  FLUE DAMPER BE INSTALLED IN THE SMOKE  PIPE BETWEEN THE STOVE AND THE CHIMNEY. The th
                    
                    Краткое содержание страницы № 7 
                    
                        ChImNEY & vENTINg Possible causes of insufficient draft; dimensions of the liner be at least as large as the ap- A. Chimney Leaks - Air leaking in around a loose fit- pliance flue outlet and no larger than 125% of the col- ting cleanout door, flue pipe joints and/or seams not  lar for a round flue. An example, a 8” flue collar is 50  secured, improper plug openings or defective ma- square inches. Increased by 25% would be 63 square  sonry. inches, or approximately a 9” round flue. In general  B.
                    
                    Краткое содержание страницы № 8 
                    
                        OPErATINg INSTruCTIONS The SF250 is approved for use with coal only. Increasing heat From A low Fire burning wood or other such fuels in this stove, Every effort should be made not to let a coal fire burn  except for the purpose of igniting a coal fire, is so long that it has started to die. This will cause the  prohibited. reloading process to be much longer, and there is a  good posibility of losing the fire.  Starting A Fire Do not shake or stir a low fire. Begin by opening the draft control 
                    
                    Краткое содержание страницы № 9 
                    
                        mAINTENANCE ShAKEr  hANdlE (external) grATES ShAKEr  bAr grATE lINK Close-up view of grate system components Periodic and Normal Everyday maintenance Blower Motor- Clean periodically to remove pet hair  and lint from the intake and fan. Spiral Chamber Cleanout Grates- Keep ash pan empty. CAUTION: BEFORE CLEANING THE CHIMNEY AND  SMOKE PIPE, BE SURE THE FIRE IS OUT AND THE  STOVE IS COOL. Avoid Chimney Fires. On a regular schedule, check  for creosote and soot buildup in the chimney, smoke  pipe,
                    
                    Краткое содержание страницы № 10 
                    
                        wATEr COIl OPTION water Coil Installation Use a hole saw and the template sup- plied with the coil to make two holes  through the side wall of the stove. Keep  the coil holes above the firebrick, and  away from the loading door. Place one  of the supplied nuts on each leg of the  coil. Place the coil through the holes in  the stove, and adjust the nuts so that the  pipes stick out about 1¼” to 1½” from  the sidewall of the stove. Put flat wash- ers and nuts on the outside, and tighten  within ¼ 
                    
                    Краткое содержание страницы № 11 
                    
                        wATEr COIl OPTION Example 1: Thermo-siphon Method. This is the simplest and most economical method, providing the existing  water heater (storage tank) is within 10 feet of the stove. The water inlet, where the Temp/Pressure relief valve  is located, must be higher than the top leg of the water coil. The storage tank should be elevated, if necessary,  to allow for proper thermo-siphon action. A). Turn off the water heater and the water supply to it. Drain the tank completely. B). Remove the Temp
                    
                    Краткое содержание страницы № 12 
                    
                        TESTINg lAbEl * This appliance is also approved for installation into a shop                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Краткое содержание страницы № 13 
                    
                        3                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Краткое содержание страницы № 14 
                    
                        4                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Краткое содержание страницы № 15 
                    
                        Notes 5                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Краткое содержание страницы № 16