Краткое содержание страницы № 1 
                    
                                    REV. E 
 
TM 
Cooler is Better!
 
USER’S 
MANUAL    
 
 
 
 
 
 
BLAST CHILLERS (SHOCK FREEZERS) 
MODEL AP24BC250-3 
MODEL AP24BCF300-3 
MODEL AP40BC350-3 
MODEL AP40BCF450-3 
 
 
 
 
American Panel Corporation 
5800 S.E. 78th Street, Ocala, Florida 34472-3412 
Phone: (352) 245-7055 Fax: (352) 245-0726  
E-mail: service@americanpanel.com                                                                                                                                                     
                    
                    Краткое содержание страницы № 2 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   INDEX  INTRODUCTION 3  CONTROLLER FEATURES 3  OPERATING MODES 3  AUTOMATIC MODE 3  MANUAL MODE 4  OPERATING CYCLES 4  PRINTER (OPTIONAL) 4  PC CONNECTION (OPTIONAL) 4  INSTALLATION OF REMOTE UNITS 5  REQUIREMENTS TO BE MET DURING INSTALLATION (8 STEPS) 5  INSTALLATION AT THE SAME LEVEL 5  INSTALLATION AT DIFFERENT LEVELS 6  CONNECTION PIPING FOR REMOTE CONDENSING UNITS 6  INSTALLATION 7  WARNINGS 7  PREPARATION 7  INSTALLATION 7  LOCA
                    
                    Краткое содержание страницы № 3 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   MANUAL SOFT CYCLE PARAMETERS PROGRAMMING 22  MANUAL HARD CYCLE PARAMETERS PROGRAMMING 23  MANUAL SHOCK CYCLE PARAMETERS PROGRAMMING 24  3. RECIPE NAME PROGRAMMING 25  OPERATION 26  1. AUTOMATIC MODE - SOFT CHILL 26  2. MANUAL MODE - SOFT CHILL 27  3. HARD CHILL CYCLE 28  4. SHOCK FREEZE CYCLE 29  5. UV (STERILIZATION) CYCLE 29  6. DEFROST CYCLE 29  7. HEATED FOOD PROBE 30  8. PREPARING AND USING THE OPTIONAL PRINTER 31  9. TO CLEAR DA
                    
                    Краткое содержание страницы № 4 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   INTRODUCTION    Blast Chiller Models AP24BC250-3 and AP40BC350-3 are used to rapidly chill cooked foods to  temperatures suitable for refrigerated storage. They are capable of lowering the core temperature  o o of most foods from 160 F to 40 F in 90 minutes. Chiller/Freezer Models AP24BCF300-3 and  AP40BCF450-3 have the same chilling capabilities as the Blast Chiller Models and when the shock  o  freezing option is selected, are capab
                    
                    Краткое содержание страницы № 5 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   MANUAL MODE    Operating time is set manually, by the operator, for the meal that has been chosen. Air  temperature is controlled by the air probe. If the food probes have been inserted into the food they  will provide temperature readouts only. The unit will automatically switch into the holding mode at  the end of the cycle.      OPERATING CYCLES    The operator can choose from the following 6 operating cycles:    MODE FOOD TEMP. US
                    
                    Краткое содержание страницы № 6 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual     INSTALLATION OF REMOTE UNITS    REQUIREMENTS TO BE MET DURING INSTALLATION (8 STEPS)                                  COMPRESSOR     FIG. 1 FIG. 2 1. Inclination of the piping. 2. Fastening of brackets on insulated piping.      FIG. 3 FIG. 4 3. Airtight welding.  4. Create the vacuum and load the line.    5. Check for leaks.  6. Open the shut-off valves (A & B, FIG.4) on both sides of remote unit and of cabinet.  7. Check the exact 
                    
                    Краткое содержание страницы № 7 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual       INSTALLATION AT DIFFERENT LEVELS    If the remote condensing unit is installed at a higher level than the cabinet (FIG. 6) insert a siphon  in the return line at every 6 ft. of difference in height. If the remote condensing unit is installed at a  lower level than the cabinet (FIG. 7) it is not necessary to insert any siphons.                                                                                                   FIG. 6 
                    
                    Краткое содержание страницы № 8 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual     INSTALLATION    WARNINGS    READ ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE YOU ATTEMPT TO INSTALL  THE EQUIPMENT.    ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE PERFORMING  ANY SERVICE OR MAINTENANCE.     INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY  APPROVED & AUTHORIZED BY AMERICAN PANEL CORPORATION.  DOING OTHERWISE  MAY VOID THE WARRANTY.    Note: Any changes made to the equipment with
                    
                    Краткое содержание страницы № 9 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   ELECTRICAL AND REFRIGERATION SPECIFICATIONS    CABINET REMOTE CONSENSER  MODEL VOLTAGE  POWER SUPPLY BTU/H AT 14°F EVAP. TEMP.  TYPE  AMPS  CORD & 105°F COND. TEMP.  AP24BC250-3 208/3/60 8 14-4 25,000 MEDIUM TEMP.  -10°F/+40°F  AP24BCF300-3 208/3/60 8 14-4 50,000 MEDIUM/LOW TEMP.  -40°F/+40°F AP40BC350-3 208/3/60 10 14-4 35,000 MEDIUM TEMP.  -10°F/+40°F  AP40BCF450-3 208/3/60 10 14-4 70,000 MEDIUM/LOW TEMP.  -40°F/+40°F   NOTES:  1. T
                    
                    Краткое содержание страницы № 10 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   l. Make sure that the fans inside the cabinet rotate clockwise.  m. Make sure that the cabinet has been leveled.        SPACES AROUND THE CABINET    • At least 15" clear space is required above  the unit for service.    • At least 6" clear space is required on both  sides of the cabinet.    • At least 6" clear space is required on the  rear of the cabinet for drain hookup and  maintenance.    • Enough space should be provided in front
                    
                    Краткое содержание страницы № 11 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   USING THE HURRICHILL™ TECHNOLOGY      BLAST CHILLING    All cooked food rapidly loses its quality and aroma if it is not served promptly. Natural bacteria  growth, the main reason why food becomes stale, takes place at an exponential rate between  140°F and 40°F. However lower temperatures have a hibernating effect that increases as the  temperature drops, thereby gradually reducing bacterial activity until it stops altogether.  Only 
                    
                    Краткое содержание страницы № 12 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   PANNING AND LOADING    PANNING    1. Standard pan depth is 2-1/2”. Other depths can be used but are not recommended as their  use would require an increase in the cycle time.    2. Stainless steel or aluminum pans are recommended, as plastic containers will increase the  chilling time.    3. Crockery or stainless steel cylinders, 6” dia. and 10” max. height, are acceptable.    4. Slack filled Cryovac bags can be used if placed on wire
                    
                    Краткое содержание страницы № 13 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   CONTROL PANEL FOR MODELS AP24 & AP40  BLAST CHILLERS / SHOCK FREEZERS                                                                                                        12                                                                                                                                                                                                                                                                       
                    
                    Краткое содержание страницы № 14 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   KEYBOARD KEYS     ON/OFF & START/STOP  CYCLE KEYS  ON/OFF SOFT CYCLE       START/STOP HARD CYCLE        SHOCK CYCLE      PROGRAMMING KEYS AUTOMATIC CYCLE     UP MANUAL CYCLE        DOWN UV LIGHT CYCLE        SELECT DEFROST CYCLE       ENTER PRINT         HEAT PROBE CYCLE       KEY COMBINATIONS   Initial Programming state – to initially set the device  o With the display reading "OFF", press and hold  (“START/STOP”) for 5 seconds   Cyc
                    
                    Краткое содержание страницы № 15 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   PROGRAMMING    1. INITIAL PROGRAMMING    NOTE:  Initial programming is preset at the factory.  Use this section only if changes are  desired.  If no changes are to be made, skip to Page 17 ( 2. Programming the cycles ).    OFF  a. With the display reading "OFF", press     ("START/STOP") for a few seconds.          INITIAL PROGRAMMING      b. To change the language, press  or  then    SELECT LANGUAGE  ENGLISH   ENGLISH    Blinks  press
                    
                    Краткое содержание страницы № 16 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual    INITIAL PROGRAMMING    g. To set the day, press  or  then press  SET DAY  03(day) 03    Blinks .     INITIAL PROGRAMMING  h. To set the hour, press  or  (be sure to    continue to press the buttons until the hour and "AM"  SET TIME  10(hours) 10:25 AM    Blinks or "PM" show correctly) then press .   INITIAL PROGRAMMING    i. To set the minutes, press  or  then press  SET TIME  25(minutes) 10:25 AM    Blinks .   INITIAL PROGRAMMING   
                    
                    Краткое содержание страницы № 17 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual     The low food alarm temperature should be left at    o  INITIAL PROGRAMMING  35 F. However, to make a change:  SOFT & HARD  LOW FOOD ALARM  35  Blinks o. To change the temperature, press  or   35 °F    then press .   INITIAL PROGRAMMING    p. To change to YES or NO, press  or  then  SHOCK FREEZE?  YES Blinks   YES *    press .  * YES for shock freezers (AP24BCF300-3, AP40BCF450-3)     NO for blast chillers (AP24BC250-3, AP40BC350-3) 
                    
                    Краткое содержание страницы № 18 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual     For YES, the display will show:    INITIAL PROGRAMMING  The printer baud rate should be left at 1200.    However, to make a change:  PRINTER BAUDRATE  1200 Blinks 1200    x. To change the baud rate, press  or  then  press .    INITIAL PROGRAMMING    y. To change the timing, press  or  then    PRINT & SAVE EVENTS  15 Blinks   EVERY         15 MIN    press .    INITIAL PROGRAMMING    z. To change to YES or NO, press  or  then  PRINT D
                    
                    Краткое содержание страницы № 19 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   AUTOMATIC SOFT CYCLE PARAMETERS PROGRAMMING         PARAM. PROGRAMMING  The LED for "A" will be "ON".  AUTOMATIC MODE  The LED'S for cycles will be blinking.  CHOOSE  PROGRAMMING CYCLE    c. Press . The LED for "SOFT" will be steady  "ON".  PARAM. PROGRAMMING  AUTOMATIC SOFT CYCLE  d. To change the temperature, press  or   LOW AIR TEMPERATURE  28 Blinks 28 °F    then press .  PARAM. PROGRAMMING  AUTOMATIC SOFT CYCLE  e. To change the 
                    
                    Краткое содержание страницы № 20 
                    
                        AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP40BCF450-3 Manual   then press .  o *  0 F for shock freezers (AP24BCF300-3, AP40BCF450-3)  o   10 F for blast chillers (AP24BC250-3, AP40BC350-3)  PARAM. PROGRAMMING  AUTOMATIC HARD CYCLE  k. To change the temperature, press  or     HIGH AIR TEMP PART 1  10 Blinks    10 °F **    then press .  o ** 10 F for shock freezers (AP24BCF300-3, AP40BCF450-3)  o     20 F for blast chillers (AP24BC250-3, AP40BC350-3)  PARAM. PROGRAMMING  AUTOMATIC HARD CYCLE  l. T