Краткое содержание страницы № 1 
                    
                        OPERATOR’S MANUAL
Manuel de l’opérateur 
Manual del operador
PORTABLE GENERATOR
Générateur portable
Generador portátil
RD8000 / RD80011
Series / Série / Serie
To register your RIDGID 
product, please visit:  
http://register.RIDGID.com
Pour enregistrer votre 
produit de RIDGID,  
s’il vous plaît la visite: 
http://register.RIDGID.com
Para registrar su producto 
de RIDGID, por favor visita: 
http://register.RIDGID.com
NEUTRAL BONDED TO FRAME
(CONNECTEUR NEUTRE RELIÉ AU CADRE, PUNTO NEUTRO CONECTA
                    
                    Краткое содержание страницы № 2 
                    
                        TABLE OF CONTENTS  	 Introduction ..................................................................................................................................................................... 2  	 Important Safety Instructions .......................................................................................................................................3-4  	 Specific Safety Rules ..................................................................................................
                    
                    Краткое содержание страницы № 3 
                    
                        IMPORTANT SAFETy INSTRUCTIONS 	 Keep all bystanders, children, and pets at least 10 feet  away. DANGER: Carbon Monoxide. Using a generator indoors WIll  	 Wear sturdy and dry shoes or boots. Do not operate while  KIll YOU IN MINUTES. barefoot. Generator exhaust contains high levels of carbon  	 Do not operate generator when you are tired or under the  monoxide (CO), a poisonous gas you cannot see or  influence of drugs, alcohol, or medication. smell. If you can smell the generator exhaust, yo
                    
                    Краткое содержание страницы № 4 
                    
                        IMPORTANT SAFETy INSTRUCTIONS 	 Maintain the unit per maintenance instructions in this 	 Inspect the unit before each use for loose fasteners, fuel  Operator’s Manual. leaks, etc. Replace damaged parts. SPECIFIC SAFETy RULES 	  Do not connect to a building’s electrical system unless a  transfer switch has been properly installed by a qualified  WARNING: electrician. When this generator is used to supply a building  wiring system: generator must be installed 	  Do not allow the generator’s ga
                    
                    Краткое содержание страницы № 5 
                    
                        SyMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product. SyMBOL SIGNAL MEANING Indicates an imminently hazardous situation, which, if not avoided, will result  DANGER: in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, could result  WARNING: in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, may result in  CAUTION: minor or moderate injury.  (W
                    
                    Краткое содержание страницы № 6 
                    
                        SyMBOLS Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper  interpretation of these symbols will allow you to operate the product better and safer. SyMBOL NAME DESIGNATION/EXPLANATION Fuel and its vapors are extremely flammable and explosive. Fire  Fire/Explosion or explosion can cause severe burns or death. To reduce the risk of injury or damage, avoid contact with any hot  Hot Surface surface. To reduce the risk of serious injury, avoid
                    
                    Краткое содержание страницы № 7 
                    
                        SyMBOLS FUEL WARNING No smoking when filling with gasoline. Do not overfill. Full level is 1 in. below the  top of the fuel neck. Stop the engine for five minutes before refueling to avoid the  heat from the muffler igniting fuel vapors. ENGINE LUBRICANT WARNING You must add lubricant before first operating the generator. The oil reservoir  capacity is 1.1 qt. Always check the lubricant level before each operation. The  lubricant level should always register between the hatched areas on the dips
                    
                    Краткое содержание страницы № 8 
                    
                        ELECTRICAL ELECTRIC MOTOR LOADS It is characteristic of common electric motors in normal operation to draw up to six times their running current while start- ing. This table may be used to estimate the watts required to start “Code G” electric motors; however, if an electric motor  fails to start or reach running speed, turn off the appliance or tool immediately to avoid equipment damage. Always check  the requirements of the tool or appliance being used compared to the rated output of the gener
                    
                    Краткое содержание страницы № 9 
                    
                        ELECTRICAL 1. With nothing connected to the generator, start the engine  GENERATOR CAPACITy as described later in this manual. Make sure the generator can supply enough continuous (run- 2. Plug in and turn on the first load, preferably the largest  ning) and surge (starting) watts for the items you will power  load you have. at the same time. Follow these simple steps. 3. Permit the generator output to stabilize (engine runs  1. Select the items you will power at the same time. smoothly and atta
                    
                    Краткое содержание страницы № 10 
                    
                        FEATURES PRODUCT SPECIFICATIONS ENGINE GENERATOR Engine Type .......................................... Subaru, EX40 OHC Rated Voltage .....................................................120V/240V Bore x Stroke .............................................89 mm x 65 mm Rated Amps .................................................. 66.7 A / 33.3A Rated Output ..........................................................8,000 W Cooling System ...................................................Forced 
                    
                    Краткое содержание страницы № 11 
                    
                        ASSEMBLy WARNING: WARNING: If any parts are damaged or missing do not operate   Do not attempt to operate the generator until  this product until the parts are replaced. Use of  assembly is complete. Failure to comply could  this product with damaged or missing parts could  result in possible serious personal injury. result in serious personal injury. LOOSE PARTS LIST See Figure 4. WARNING:  The following items are included with the generator: Do not attempt to modify this product or create   Ke
                    
                    Краткое содержание страницы № 12 
                    
                        ASSEMBLy 	 Raise the handle end of the generator high enough to  gain access to the frame bottom; securely position props   WARNING: underneath to support. Keep metal objects away from the battery  terminals. Metal objects can make a connection  	 Insert an axle through the center of the wheel. from one terminal to another. Shorting the battery  	 Place a washer on the axle, then slide the axle through  terminals together may cause sparks, burns, or  the bracket on the frame.  a fire. 	 Slid
                    
                    Краткое содержание страницы № 13 
                    
                        OPERATION APPLICATIONS DANGER: This generator is designed to supply electrical power for  Carbon Monoxide. Using a generator indoors  operating compatible electrical lighting, appliances, tools,  WIll KIll YOU IN MINUTES. Generator exhaust  and motor loads. contains high levels of carbon monoxide (CO), a  poisonous gas you cannot see or smell. If you can BEFORE OPERATING THE UNIT smell the generator exhaust, you are breathing CO.  	 Only use OUTSIDE and far away from windows, doors,  But even i
                    
                    Краткое содержание страницы № 14 
                    
                        OPERATION resulting from the use of an oxygenated fuel containing more  CHECKING/ADDING FUEL  than the percentages of oxygenates stated previously are  See Figure 13. not covered under warranty. 	 Remove the fuel cap. 	 Fill the fuel tank to 1 in. below the top of the fuel neck. CAUTION: 	 Replace and secure the fuel cap. On a level surface with the engine off, check the  NOTE: Always use unleaded gasoline with a pump octane  lubricant level before each use of the generator.  rating of 86 or 
                    
                    Краткое содержание страницы № 15 
                    
                        OPERATION ™ Reading GenSmart Monitoring System  MOVING THE GENERATOR At startup, the unit will display a message instructing the  See Figure 17. operator to read and understand the operator’s manual   Turn the off switch OFF ( O ). Disconnect any equipment  before using this product. that is plugged into the generator. While the generator is running, the panel will display a  	 Turn the fuel valve to the OFF position. power bar, load percentage, and total hours the unit has   Allow 30 minutes
                    
                    Краткое содержание страницы № 16 
                    
                        OPERATION STARTING THE ENGINE STOPPING THE ENGINE See Figure 20. See Figure 20. NOTE: If location of generator is not level, the unit may not To stop the engine under normal operating conditions: start or may shut down during operation. 	 Remove any load from the generator. 	 Unplug all loads from the generator.  Turn the switch key to “OFF”or press and hold the off  	 Turn the fuel valve to the ON position. switch until the engine stops. 	 Move the choke lever right to the START position. 
                    
                    Краткое содержание страницы № 17 
                    
                        MAINTENANCE 	 Apply a light coat of engine lubricant to the element, then  squeeze it out. WARNING: When servicing, use only identical RIDGID  	 Replace the element in the air filter unit. replacement parts. Use of any other parts may  	 Replace the air filter cover and latch to secure. create a hazard or cause product damage. NOTE: Do not run the generator without the air filter. Rapid  engine wear will result. Only the parts shown on the parts list are intended to be  repaired or replaced b
                    
                    Краткое содержание страницы № 18 
                    
                        MAINTENANCE 	 Turn the fuel valve to the ON position. CLEANING THE EXHAUST PORT AND   MUFFLER 	 For better fuel drainage, please tilt the unit toward the  fuel petcock slightly (approximately 1 in.). Depending on the type of fuel used, the type and amount of  lubricant used, and/or your operating conditions, the exhaust  	 When the fuel has drained from the tank, close the fuel  port and muffler may become blocked with carbon deposits.  valve and reinstall fuel line securely on petcock. If yo
                    
                    Краткое содержание страницы № 19 
                    
                        MAINTENANCE STORAGE When preparing the generator for storage, allow the unit to cool completely then follow the guidelines below. STORAGE TIME PRIOR TO STORING less than 2 months 	 Drain gasoline from tank and dispose of in a suitable container according to state and local   ordinances. 2 months to 1 year 	 Drain fuel from carburetor. 	 Drain gasoline from tank and dispose of in a suitable container according to state and local   ordinances. 1 year or more 	 Drain fuel from the carburetor. 
                    
                    Краткое содержание страницы № 20 
                    
                        TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine will not start. The engine switch key is on OFF. Turn the engine switch key to ON.  No fuel. Fill fuel tank. lubricant level is low. Check engine lubricant level and fill, if   necessary. Fuel valve is OFF. Turn fuel valve ON. Spark plug faulty, fouled, or improperly Replace spark plug. gapped.   Choke lever is in RUN position. Move choke lever to START position. Engine stored without treating or Drain fuel and carburetor. Refuel with  drain