Краткое содержание страницы № 1 
                    
                        OPERATION AND PARTS MANUAL
GLOBUG SERIES
MODEL GB114BS/BP
LIGHTING SYSTEM
Revision #3 (01/06/09)
To fi nd the latest revision of this 
publication, visit our website at: 
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.                                                                                                                                                                                                                                                                  
                    
                    Краткое содержание страницы № 2 
                    
                        TABLE OF CONTENTS COMPONENT DRAWINGS MQ GLOBUG LIGHTING  Nameplate and Decals ..................................... 32-33 SYSTEM Ballast Assembly S/N G30001 & Below ........... 34-35 Table of Contents ..................................................... 2 Ballast Assembly S/N G30002 & Above ........... 36-37 Parts Ordering Procedures ...................................... 3 Fan Blower/Lamp Base Assembly .................... 38-39 Safety Information ..............................................
                    
                    Краткое содержание страницы № 3 
                    
                        PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Effective: st January 1 , 2006 Best Deal! Order via Internet (Dealers Only): If you have an MQ Account, to obtain a Order parts on-line using Multiquip’s SmartEquip website! Username and Password, E-mail us at: parts@multiquip.com. ■ View Parts Diagrams To obtain an MQ Account, contact your ■ Order Parts District Sales Manager for more information. ■ Print Specification Information Use the internet an
                    
                    Краткое содержание страницы № 4 
                    
                        SAFETY INFORMATION Do not operate or service the equipment before reading  GENERAL SAFETY the entire manual. Safety precautions should be followed    CAUTION at all times when operating this equipment.  Failure to read and understand the safety   NEVER operate this equipment without proper protective messages and operating instructions could  clothing, shatterproof glasses, respiratory protection,  result in injury to yourself and others. hearing protection, steel-toed boots and other protectiv
                    
                    Краткое содержание страницы № 5 
                    
                        SAFETY INFORMATION LIGHTING SYSTEM SAFETY   NOTICE   DANGER  NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot  NEVER use lighting system in rain, snow or  spots, reducing the service life of the lamp. areas of high humidity that could generate  electrical storms.  ALWAYS make sure lamp surface is clean and dry.   WARNING  ALWAYS replace with MQ recommended type lamp. See  parts section of this manual.  NEVER disconnect any emergency 
                    
                    Краткое содержание страницы № 6 
                    
                        SAFETY INFORMATION GENERATOR SAFETY Power Cord/Cable Safety If using a generator to power lighting system,   DANGER refer to applicable generator manual safety   NEVER let power cords or cables lay in water. information section.  NEVER use damaged or worn cables or cords. Inspect ELECTRICAL SAFETY for cuts in the insulation   DANGER  NEVER grab or touch a live power  cord or cable with wet hands. The   Lighting system is equipped with a ground pin on the  possibility exists of electrical sho
                    
                    Краткое содержание страницы № 7 
                    
                        SAFETY INFORMATION LOADING AND UNLOADING TRANSPORTING SAFETY If lighting system is equipped with a transport lifting hook,   NOTICE refer to the following safety information.  When transporting the lighting system, if applicable,   CAUTION always place in stow position and place mast in its carrying case.  Before lifting, make sure that lighting system parts are  not damaged and screws are not loosened or lost.  ALWAYS remove balloon/lamp assembly from the mast when transporting lighting syst
                    
                    Краткое содержание страницы № 8 
                    
                        SPECIFICATIONS Table 1. Specifi cations GloBug Lighting System Model GB114BS/GB114BP Input Voltage 120 VAC Ballast Magnetic Ballast 60 Hz Frequency 60 Hz Single-Phase Max. Current 9.5 Amps Lamp Lamp Type 1000 Watt Metal Halide Lumens 112,000 Light Coverage (360°) 150 ft. (45.72 meters) Surface Temperature (Longitudinal) 476.6°F (247°C) Max. Surface Temperature (Transversal) 417.2°F (214°C) Max. Fan Motor Balloon Fan Motor 115  VAC, 60 Hz Max. Current .360 Amps Pressure 31.26 PSI (215.6 kPA) Ballo
                    
                    Краткое содержание страницы № 9 
                    
                        DIMENSIONS (GB114BS) Figure 1. Dimensions (GB114BS) Table 2. Dimensions Dimension  Reference Letter Dimension in. (mm.) Reference Letter in. (mm.) 88.0 -108.0 in. 35.00 in.  A D  (2,230 - 2,730 mm.) (900 mm.) 35.00 in.  B 59 in. (1,500 mm.) E (900 mm.) C 47.16 in. (1,200 mm.) GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) — PAGE 9                                                                                                                                   
                    
                    Краткое содержание страницы № 10 
                    
                        DIMENSIONS (GB114BP) B A Figure 2. Dimensions (GB114BP) Table 3. Dimensions Reference  Dimension in. (mm.) Letter A 28.00 in. (712 mm.) B 47.16 in. (1,200 mm.) PAGE 10 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09)                                                                                                                                                                                                                                                       
                    
                    Краткое содержание страницы № 11 
                    
                        FOOTCANDLE PLOT  360° Coverage .5 1 2 5 10 Values listed as footcandles Scale: Grid = 50 ft. (15.25 meters) Figure 3. Floodlight Footcandle Plot (BAL-115 Drum Shaped) GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) — PAGE 11                                                                                                                                                                                                                                                
                    
                    Краткое содержание страницы № 12 
                    
                        GENERAL INFORMATION The Multiquip GloBug GB114BS, and GB114BP are  GB114BP general purpose portable glare-free lighting systems.  When only a complete lamp assembly is required please  Typical applications for these types of lighting systems  order Model GB114BP.  This model number includes the  include construction sites, emergency road crews and  lamp, protective guard, balloon protective covering and all  backyard parties.  other components that make up the lamp assemby. BALLOON ENVELOPES TRA
                    
                    Краткое содержание страницы № 13 
                    
                        NOTES GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) — PAGE 13                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Краткое содержание страницы № 14 
                    
                        COMPONENTS Figure 5. Major Components PAGE 14 — GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09)                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Краткое содержание страницы № 15 
                    
                        COMPONENTS Figure 5 shows the location of the components for the 6. T-Handle Bolt Lock — Always tighten this lock to hold  GloBug lighting system. The function of each component the lamp/balloon securely in place. is described below: 7. Balloon — This balloon is made of heat-resistant  1. Lamp Guard — This guard (cage) protects the lamp nylon, with a diameter of 47 inches (1200 mm). from being hit by objects. 8. Offset Pole — Supports lamp assembly when attached  2. Lamp — 1000 watt metal-halide
                    
                    Краткое содержание страницы № 16 
                    
                        SETUP 9. Using 17 mm wrench, tighten both bolts (M) on the   NOTICE offset adapter clamp  (K) securely. The pole clamp assembly used in this setup procedure  10. Place lamp assembly (N) onto offset pole (B). Tighten  is a  dual type clamp. One side of the clamp is for the  T-handle bolt (O) securely. attachment of the main pole of the lighting system. The  other side of the clamp is used for the attachment of  a support pole that is usually connected to a piece of  N LAMP equipment such as a pav
                    
                    Краткое содержание страницы № 17 
                    
                        SETUP REMOVING THE PROTECTIVE COVERING CONNECTING POWER CABLE  1. Expose the balloon by pulling down on the velcro tab 1. Connect 16.4 ft. (5 meters) lamp power cable (Figure 8)  and unzip the protective cover as shown in Figure 7. to the balloon power cable. PROTECTIVE STEP 1 COVER UNZIP PROTECTIVE COVER BALLOON POWER LAMP BALOON CABLE ASSEMBLY STEP 2 FOLD PROTECTIVE VELCRO COVER INTO ITSELF TAB BALLOON FULLY EXPOSED BALLAST LAMP POWER CABLE Figure 8. Connecting Lamp Power Cable 2. Attach both 
                    
                    Краткое содержание страницы № 18 
                    
                        OPERATION RAISING THE EXTENSION POLE APPLYING POWER 1. Before raising the extension pole, make sure the 1. Make sure the power ON/OFF switch (Figure 10)  T-handle bolt lock (Figure 6-O) is securely tightened. located near the bottom of the ballast is in the OFF  This will prevent the balloon/lamp assembly from falling position. off. In addition make sure that the lamp power cable  is connected to the mating end of the power source  cable. ON/OFF 2. Raise extension pole (Figure 6-L) to desired he
                    
                    Краткое содержание страницы № 19 
                    
                        OPERATION/SHUTDOWN SHUTDOWN  NOTICE 1. Place the ON/OFF switch on the ballast to the OFF  ALWAYS Make sure ballast is securely mounted to   position. The balloon should begin to defl ate and the  a surface where it will not move, slip or fall. This will  lamp turns off. prevent severe damage to the ballast.  2. If using a portable generator, shut-down the generator  3. Place the ON/OFF switch (Figure 12) on the ballast in  as referenced in the "Shutdown Section" of the supplied  the ON position. 
                    
                    Краткое содержание страницы № 20 
                    
                        STORAGE 2. Remove both S-type hooks (Figure 9) on the lamp   NOTICE power cable from the cable support holes on the offset  Allow a suffi cient amount of time (15-20 minutes) for the  pole. lamp to cool down . The possibility exists of the balloon  3. Unzip the zipper on the protective cover (Figure 14),  getting burned (touching the lamp).  and pull down cover over balloon/lamp assembly. ZIPPER LOWERING THE EXTENSION POLE  1. Using the supplied 19 mm wrench, loosen extension  clamp bolt (Figure