Краткое содержание страницы № 1 
                    
                         
Super Runner Series Gas Fryers  
Installation & Operation Manual 
 
 
Series SR42, SR52 & SR62 
 
 
 
NON-CE & 
 
 
 
For Service, Call (318) 865-1711 
 
 
Price: $10.00
Dean, 8700 Line Avenue, PO Box 51000, 
PRINTED IN THE 
UNITED STATES Shreveport, Louisiana 71135-1000 
819-5999
Shipping Address:  8700 Line Avenue, 
JULY 2005
 Shreveport, Louisiana 71106 
                                                                                                                                          
                    
                    Краткое содержание страницы № 2 
                    
                          NOTICE  This appliance is intended for professional use only and is to be operated by qualified personnel only.  A  Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified professional should  perform installation, maintenance, and repairs.  Installation, maintenance, or repairs by unqualified  personnel may void the manufacturer’s warranty.      NOTICE  This equipment must be installed in accordance with the appropriate national and local codes of the  country and/or region
                    
                    Краткое содержание страницы № 3 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 1:  INSTALLATION INSTRUCTIONS      1.1 Safety Information    Before attempting to operate your unit, read the instructions in this manual thoroughly.  Throughout this manual you will  find notations enclosed in double-bordered boxes with the symbol .   The information contained in the box concerns  actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system  to malfunction.    1.2 General Install
                    
                    Краткое содержание страницы № 4 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 1:  INSTALLATION INSTRUCTIONS      For units equipped with legs:  Lift the unit and move it into its final position.  Do not drag or push the fryer into position.  Doing so may damage the legs.  Level the unit front to back and side to side. If the fryer is not level, the unit will not  function efficiently.  Super Runner Series gas fryers cannot be curb mounted and must be equipped with either legs or  casters provided.    A. Adjust leg height with an adj
                    
                    Краткое содержание страницы № 5 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 1:  INSTALLATION INSTRUCTIONS      AUSTRALIAN REQUIREMENTS:    To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory  regulations.    CE UNITS ONLY:    Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings  and Pilot Markings are listed in the table below:      NOMINAL  MANIFOLD GAS PRESSURE  HEAT INPUT- ORIFICE ORIFICE BURNER P
                    
                    Краткое содержание страницы № 6 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 1:  INSTALLATION INSTRUCTIONS           DANGER  A manual shut-off valve must be installed in the gas supply (service) line upstream of this appliance and in  a position where it can be reached quickly in the event of an emergency.       DANGER  The fryer must be connected to the gas supply specified on the rating and serial number plate located on  the inside of the appliance door.  DO NOT ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS  NOT CONFIGUR
                    
                    Краткое содержание страницы № 7 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 1:  INSTALLATION INSTRUCTIONS        When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures apply:    ♦ Burner orifices and pilot orifice MUST be replaced.  ♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 1-3 by turning the gas-valve  adjustment screw.    ♦ After adjustment, replace the adjustment-screw cover.  ♦ Affix the new label included with the conversion kit next the existing
                    
                    Краткое содержание страницы № 8 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 1:  INSTALLATION INSTRUCTIONS        Frypot Assembly 1/2—3/4 Reducer Manifold Support Bracket Bushing Gas Valve Gas Burner Burner See Detail A 1.63-inch [41-mm] Orifice 1.30-inch [33-mm] Pressure Test Gas Manifold Spigot Orifice Gas Manifold Assembly Detail A Burner/Orifice Location Temperature Control     Typical gas valve, burner and orifice locations (SR42 shown above).        Propane Applications:  1.6  Gas Conversion Components  Proper Regulator Must 
                    
                    Краткое содержание страницы № 9 
                    
                        
                    
                    Краткое содержание страницы № 10 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 2:  OPERATION      5. Fill the frypot with oil, shortening or water to the bottom OIL LEVEL line scribed on the frypot back.  Ensure  heating tubes are covered in liquid prior to engaging burners.    NOTE:  If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath,  between and above the tubes prior to operating fryer.    6. Open the manual shut-off valve on the incoming gas supply line and rotate the gas v
                    
                    Краткое содержание страницы № 11 
                    
                        SUPER RUNNER SERIES GAS FRYERS  CHAPTER 2:  OPERATION         DANGER  "Dry-firing" the fryer will cause damage to the frypot and can cause a fire.  Always ensure that shortening,  cooking oil or water covers the burner tubes before lighting the burners.    2. With the pilot lit, push down and slowly turn the gas valve knob to the ON position.    3. Rotate the operating thermostat knob to the desired frying temperature.  The burner should light and burn with a  strong blue flame.     DANGER  If t
                    
                    Краткое содержание страницы № 12 
                    
                        300 350 ON 4 0 0 SUPER RUNNER SERIES GAS FRYERS  CHAPTER 2:  OPERATION      2.5  Wiring Diagram    CE UNITS ONLY:      WARNING DO NOT CONNECT ANY EXTERNAL ELECTRICAL POWER TO THIS UNIT TH PP TH PP THERMOPILE HONEYWELL 807-3565 OPERATING THERMOSTAT COAXIAL LEAD TO THERMOCOUPLE 812-1284 HIGH-LIMIT HONEYWELL CE         NON-CE UNITS ONLY:        CONTROL CIRCUIT PILOT GENERATOR 3C 4C 1/2 P.S.I. HONEYWELL 1C 2C OFF HIGH-LIMIT COM N/O N/C OPERATING THERMOSTAT       2-4  HONEYWELL 1/2 P.S.I. 200 250 C P
                    
                    Краткое содержание страницы № 13 
                    
                        THIS PAGE INTENTIONALLY LEFT BLANK.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Краткое содержание страницы № 14 
                    
                                                                Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana  71135-1000  Shipping Address:  8700 Line Avenue, Shreveport, Louisiana  71106  TEL  1-318-865-1711 FAX  (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135    Price: $10.00  PRINTED IN THE UNITED STATES  819-5999   JULY 05