Краткое содержание страницы № 18 
                    
                        ADJUSTMENTS /  /  GAS MANIFOLD NUMBER RATE EA.  TOTAL RATE ORIFICE  - BURNER TYPE PRESSURE PERUNIT BTUSfHR. BTUsiHR. SIZE  14-32 Nat. 4" W.C. 4 22,500 90,000 if44 - .086" dia.  Main  90,000 #54 - .0024" dia.  14-42 Prop. 10" W.C. 4 22,500  Nat. 4" WC 1 900 900 #77 - .018" dia.  1436  Pilot r  1 900 900 .Oll" dia.  Prop. 10" W.C.  Nat. 4" W.C. 5  22,500 112,500 #44 - .086" dia.  Main ,  Prop. 10" W.C. 5 22,500 112,500 #54 - .0024" dia.  18-42  900 #77 - .OlS" dia.  18-36 Nat. 4" W.C. 1 900  Pilot
                    
                    Краткое содержание страницы № 19 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Краткое содержание страницы № 20 
                    
                        DEEP FAT FRYER  PARTS  WARNING  INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID  THE WARRANTY ON THIS EQUIPMENT.  The serial plate is located on the back of the door - upper left corner.  Replacement parts may be ordered either through a Southbend Authorized Parts Depot or a South-  bend Authorized Service Agency.  When ordering, please supply the Model Number, Serial Number, Part Number, Description, plus  Finish, Type of Gas and Electrical Characteristics, as applicable.  For part
                    
                    Краткое содержание страницы № 1 
                    
                        IMPORTANT 
FOR FUTURE REFERENCE 
Please complete this informa- 
I ----LLL-- tion and retain this manual for 
the life of the equipment. 
MODEL # 
SERIAL # 
DATE PURCHASED 
A MIDDLEBY COMPANY 
OWNER’S MANUAL 
INSTALLATION 
USER’S GUIDE 
SERVICE 
PARTS 
DEEP FAT FRYER 
FRONT MANIFOLD -SECTIONAL RANGE MATCH 
MODELS: 1436,1442; l&36,16-42 
FREE STANDING - RESTAURANT RANGE MATCH 
MODEL: 14-32 
These instructions should be read thoroughly before attempting installation. Set up, 
installation and Perfo
                    
                    Краткое содержание страницы № 2 
                    
                        Congratulations! You have just purchased one of the finest pieces of heavy-duty, commercial cooking  equipment on the market today.  You will find that your new equipment, like all Southbend equipment, has been designed and manufactured  to some of the toughest standards in the industry - those of Southbend Corporation. Each piece of  Southbend equipment has been carefully engineered and designs have been verified through laboratory  tests and field installations in some of the more strenuous co
                    
                    Краткое содержание страницы № 3 
                    
                        DEEP FAT FRYER  INSTALLATION  SPECIFICATIONS  t--a---  --r  FRONT VIEW TOP VIEW SIDE VIEW  ( ) = Millimeters  DIMENSIONS:  NOTEI Model 14 Fryers - 14” (356 mm) wide x 14” (356 mm) deep; Model 18 Fryers - 18” (457 mm) wide x 18” (457 mm) deep,  ‘Model 14-32 comes standard with a shelf splasher- overall height is 56.5” (1435 mm).  *Model 14-32 only has %” gas connection: I = lo” (254 mm), J = 1.75” (44 mm).  UTILITY INFORMATION:  GAS - 14-32; 14-36; 14-42 -Total BTU 90,000  1836; 18-42-Total BTU 1
                    
                    Краткое содержание страницы № 4 
                    
                        INSTALLATION  \  WARNINGz THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED  PERSONNEL OR WARRANTY WILL BE VOIDED.  I  GENERAL:  The unit, when installed, must conform with local codes, or in the absence of local codes, with the National Fuel  Gas Code, ANSI Z223.1-Latest Edition. Canadian installation must comply with CAN/CGA-B149.1 Natural Gas  Installation Code, Code CAN/CGA-B149.2 Propane Installation Code.  INSTILIATION CLEARAN CES. AS APPLICABLE  COMBUSTIBLE NONCOMBUSTJBUE  CONSTRUCTION CONST
                    
                    Краткое содержание страницы № 5 
                    
                        INSTALLATION  t  W-G: THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED  PERSONNEL OR WARRANTY WILL BE VOIDED.  SCREW - 1146201  j==, PAD -  1172650  i  LEG -  1174260  1174264 - WlTH BRAKE i w  1174265 - Wl-lHOUT BRAKE  B  LEG INSTALLATION  CASTER INSTALLATION  LEGS OR OPTIONAL CASTERS:  1. A set of legs or casters are packed in the unit. A threaded receptacle is fastened to the base frame  at each corner. Each leg or caster has a similar mating thread.  2. Raise unit sufhciently to allow legs or 
                    
                    Краткое содержание страницы № 6 
                    
                        INSTALLATION  \  WARNING: THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED  PERSONNEL OR WARRANTY WILL BE VOfDED.  GAS CONNECTIONS:  The AGA. serial plate located on the back of the door (upper left corner> indicates the type of gas  your unit is equipped to burn. Do Not connect to any other gas type.  These models are design certified for operation on Natural or Propane gases.  The appliance should be connected ONLY to the type of gas for which it is equipped. All Southbend  equipment is adjusted
                    
                    Краткое содержание страницы № 7 
                    
                        INSTALLATION  B. MODELS 1442,1436,18-42 and 18-36  INDIVIDUAL UNITS  1. Remove valve panel.  2. Use a long spirit level four ways; across the front top rail and rear collar plate, and along  each edge.  3. (a) For units without a rear gas connection connect the gas supply to the right or  left side of the manifold. Be sure to cap the unused side.  (b) For units with a rear gas connection the supply to the unit will be made at the right  rear. Be certain both ends of the manifold are capped.  4. 
                    
                    Краткое содержание страницы № 8 
                    
                        INSTALLATION  \  WARNING THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED  PERSONNEL OR WARRANTY  WILL BE VOIDED.  MOUNTlNG SHELF OR BACKSPLASH  (SECTIONAL ONLY)  INSTALLATlON INSTRUCTIONS  MODELS: 14-36,14-42, l&36,16-42  1. Front panel “A” is fastened with six (6)  sheet metal screws. Remove screws  and panel is loose.  2.  Remove nuts and lock washers from  collar plate studs “C” on fryer.  3. Lower the shelf (or backsplash) onto  fryer allowing studs “C” to enter holes  in the shelf bracket. S
                    
                    Краткое содержание страницы № 9 
                    
                        INSTALLATION  t  PERFORMANCE CHECH:  The following items should be checked before or within the first 30 days of operation by a qualified  service technician.  1. Verify correct gas type.  2. Gas pressure.  3. Check gas supply connections.  4. Internal gas connections.  5. Internal electrical connections.  6. Pilots - adjustment and ignition.  7. Burners - adjustment and ignition.  8. Thermostat - check for correct calibration - calibrate if necessary.  9. Check for correct position of flue exte
                    
                    Краткое содержание страницы № 10 
                    
                        USER’S GUIDE  LIMITED WARRANTY  Southbend warrants that the equipment, as supplied by the factory to the original purchasers, is free from defects in  materials and workmanship. Should any part thereof become defective as a result of normal use within the period and  limits defined below, then at the option of Southbend such parts will be repaired or replaced by Southbend or its Autho-  rized Service Agency. This warranty is subject to the following conditions:  If upon inspection by Southbend o
                    
                    Краткое содержание страницы № 11 
                    
                        OPERATION  ii  WARNING THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED  PERSONNEL OR WARJMNTY WILL BE VOIDED.  THEORY OF OPERATION: All Southbend Fryers are immersion tube fryers. This is the most  efficient method of transmitting heat into the frying compound.  The tubes are actually large heat exchangers. Each tube is heated by a burner at its front, which  propels its flame and heat into the tube, toward the rear, where it is vented into a flue box. The  combined heat transfer area of the tube
                    
                    Краткое содержание страницы № 12 
                    
                        OPERATION  8  C. FtELIGHITINGz  1. Shutoffallgas.  2. wait 5 minutes.  3. Repeat “LIGHTING” instructions in Section “A”  CAUTION: IF YOU SMELL GAS DURING THE LIGHTING PROCEDURE, IMMEDLATELY  SHUT OFF THE GAS SUPPLY UNTIL TUELEAUHAS BEEN CORRECTED.  WARNING In the event of main burner ignition failure, a 5 minute purge period must be  observed prior to re-establishing ignition source.  FILUNGTHEFRYgETIzE:  1. Close drain valve completely before Ding the f?y kettle.  2. When the fryer is new, fill
                    
                    Краткое содержание страницы № 13 
                    
                        
                    
                    Краткое содержание страницы № 14 
                    
                        COOKING HINTS  PERJTOFtMANCE:  TYPICAL PRODUCTION 14"FRYExs 18" FRYERS  Potatoes - Raw to finished 70 Lbs. per Hr. 115 Lbs. per Hr.  - Blanched to finished 285 Lbs. per Hr. 360 Lbs. per Hr.  Chicken -Raw to finished  45 Lbs. per Hr. 60 Lbs. per Hr.  -Blanched to finished 85 Lbs. per Hr.  110 Lbs. per Hr.  WARING: Adjustments and service work may be performed only by a qualified technician  who is experienced in, and knowledgeable with, the operation of commercial gas cooking  equipment. However,
                    
                    Краткое содержание страницы № 15 
                    
                        MAINTENANCE  FRY KETTLE CLEANING WEEKLY:  1. Follow steps 1, 2, 3 and 4 above.  2. Close drain valve and fill kettle with a solution of warm water and a strong detergent or other  strong cleanser.  3. Relight the fryer and bring the solution to a gentle boil for at least five minutes.  4. Turn off main burners and let the solution stand until the gum deposits are softened and the  carbon spots and burned grease spots can be rubbed off.  5. Scrub the kettle walls and heat tubes, then drain out ke
                    
                    Краткое содержание страницы № 16 
                    
                        DEEP FAT FRYER  SERVICE  ADJUSTMENTS ’  /  WARNING Adjustments and service work may be performed only by a qualified technician who is  experienced in, and knowledgeable with, the operation of commercial gas cooking equipment.  However, to assure your confidence, contact your Authorized Service Agency for reliable service,  dependable advice or other assistance, and for genuine factory parts.  WARNING Appliances equipped with casters have been installed with a restraint to limit their  movement 
                    
                    Краткое содержание страницы № 17 
                    
                        ADJUSTMENTS  PRESSURE REGULATOR:  The pressure regulator is factory set at 4 N W.C. for natural gas and 10 N WC. for propane gas. lb check  the manifold pressure:  1.  Turn thermostat “OFF” (lowest position) and Unitrol knob to “PILOT” setting.  2. Remove pressure tap plug from burner manifold located directly above the Unitrol in the cabinet.  3. Install a fitting appropriate to connect a manometer.  4. Turn Unitrol dial to “ON” position and thermostat “ON.” The burners will ignite. Be certain