Fujitsu Siemens Computers S60 user manual

User manual for the device Fujitsu Siemens Computers S60

Device: Fujitsu Siemens Computers S60
Category: Network Card
Manufacturer: Fujitsu Siemens Computers
Size: 2.12 MB
Added : 8/10/2014
Number of pages: 98
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu Siemens Computers S60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu Siemens Computers S60.

For your convenience

If looking through the Fujitsu Siemens Computers S60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu Siemens Computers S60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu Siemens Computers S60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu Siemens Computers S60 User manual - Online PDF
Advertisement
« Page 1 of 98 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu Siemens Computers S60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu Siemens Computers S60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Primergy
PRIMERGY S60
Storage Subsystem

Xenia Fierley
Fujitsu SiemensComputers GmbH cognitas PS
81730 München
e-mail: email:manuals@fujitsu-siemens.com
Tel.: (089) 61001-157
Fax: 0 700 / 372 00000
U41221-J-Z156-1-74
Sprachen: En
Edition September 2001

Summary of the content on the page No. 2

Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion on this manual. Your feedback helps us to optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included at the back of the manual. There you will also find the addresses of the relevant User Documentation Department Copyright and Trademarks Copyright © 2001 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; r

Summary of the content on the page No. 3

German English

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Contents 1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Notation Conventions . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 Structure of the Manual . . . . . . . . . . . . . . . . . . . . . . 3 1.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 6

Contents 7 FC Hard Disk Drives . . . . . . . . . . . . . . . . . . . . . . . 37 7.1 Handling Hard Disk Drives/HDD Modules . . . . . . . . . . . . 37 7.2 Installing/Removing HDD/Dummy Module . . . . . . . . . . . . 38 7.3 Hot Swap for FC HDD Modules . . . . . . . . . . . . . . . . . . 42 7.4 Identification Marks and Loop Addresses . . . . . . . . . . . . . 43 8 Plug-in Board Modules . . . . . . . . . . . . . .

Summary of the content on the page No. 7

Contents 11.1.3 Server Management Status . . . . . . . . . . . . . . . . . . . 74 11.1.3.1 Server Management Status LED lights permanently . . . . . . 74 11.1.4 Storage Subsystem Switches OFF . . . . . . . . . . . . . . . 75 11.1.5 System will not boot after Installation of New HDD Modules . . 75 11.1.6 HDD READY Indicator does not light up . . . . . . . . . . . . . 75 11.1.7 Hard Disk Drives“ dead” on System Start . . . . . . . .

Summary of the content on the page No. 8

Summary of the content on the page No. 9

1 Introduction The functionality, mechanics and design of the PRIMERGY S60 storage subsystem are optimally adapted to the PRIMERGY Nxxx server compute- nodes. It can be used as rack or as floorstand model. In the 19-inch rack, the S60 subsystem occupies three height units. The PRIMERGY S60 storage subsystem use the fiber-channel technology and can accommodate up to fourteen 1-inch hard disk drives. The use of fiber-channel technology ensures high transmission speeds over long distances, us

Summary of the content on the page No. 10

Target Group Introduction I When installing PRIMERGY S60 storage subsystems in connection with ServerView please install the ServerStart CD version 4.06 or higher on each of the connected servers. See ServerView documentation for notes concerning installing and update (see also “Related publications” on page 81). 1.1 Target Group The operating instructions are intended for the person responsible for installing the hardware and correctly operating the system. The operating manual contain all

Summary of the content on the page No. 11

Introduction Structure of the Manual 1.3 Structure of the Manual The PRIMERGY S60 storage subsystem manual describes how to install and configure the subsystem and perform expansions or upgrades. You will find further information (see also entries in the chapter “Related publi- cations” on page 81):  in the “Safety, Warranty and Ergonomics” manual  in the documentation on the PRIMERGY server This manual consists of the following chapters:  Important notes This chapter contains instructions o

Summary of the content on the page No. 12

Technical Data Introduction  Configurations This part of the manual gives configuration examples.  Installation The activities needed to install and commission the storage subsystem are described.  Troubleshooting This chapter contains advice on solving problems that occur on commis- sioning or during the operation of the storage subsystem. 1.4 Technical Data Electrical Characteristics Rated voltage 100 V - 240 V Tolerance of the rated voltage +6 % / -10 % Rated frequency 50 Hz / 60 Hz Rated

Summary of the content on the page No. 13

Introduction Technical Data Environmental Conditions (according to DIN EN 60721-3-x) Climate/operation (class 3K2): Temperature 15 °C to 35°C Relative humidity 5% to 85% altitude (NN) max. 3048 m (10000 ft.) Climate/transport (class 2K2): Temperature -25°C to 60°C Relative humidity 15% to 98% altitude (NN) max. 15240 m (50000 ft.) Mechanical environmental conditions Operation Class 3M2 Transport Class 2M1 Standards Complied With Product safety and ergonomics IEC 60950 (DIN EN 60950), UL 1950, C

Summary of the content on the page No. 14

Summary of the content on the page No. 15

2 Important Notes 2.1 Notes on Safety In this section you will find information that you must note when using the storage subsystem. This device complies with the relevant safety standards for IT equipment, including electronic office machines, intended for use in the office environment. I You will also find the following safety instructions in the manual entitled “Safety, Warranty and Ergonomics“ which also includes other notes on guarantee and ergonomics. Also pay attention to the notes i

Summary of the content on the page No. 16

Notes on Safety Important Notes V CAUTION!  Check that the rated voltage specified on the device's ID plate is the same as the local line voltage.  The device must only be connected to a properly grounded wall outlet (the device is fitted with a tested and approved power cable).  Make sure that the protective grounded outlet of the building’s wiring system is freely accessible.  Switching off the device does not cut off the supply of power. To do this you must remove the power plugs. 

Summary of the content on the page No. 17

Important Notes Electrostatic Sensitive Device Label 2.2 Electrostatic Sensitive Device Label Electrostatic-sensitive components may be identified by the following sticker: Figure 1: Electrostatic Sensitive Device (ESD) sticker You must follow the instructions below when handling modules containing electrostatic-sensitive components Ê Discharge static electricity from your body (for example by touching a grounded metal object) before handling modules containing electrostatic- sensitive compone

Summary of the content on the page No. 18

CE certificate Important Notes 2.3 CE certificate The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC “Electromagnetic compatibility” and 73/23/EEC “Low voltage directive”. The device therefore qualifies for the CE certificate (CE=Communauté Européenne). 2.4 RFI Suppression All other equipment which is connected to this product must also have radio noise suppression in accordance with EC Guideline 89/336/EWG. Products which meet this requirement

Summary of the content on the page No. 19

Important Notes Notes on the Rack Model 2.6 Notes on the Rack Model  For safety reasons, at least two people are required to install the rack model because of its weight and size.  When connecting and disconnecting cables, observe the notes in the documentation for your PRIMERGY system and the comments in the “Important notes” chapter in the technical manual supplied with the rack.  Ensure that the anti-tilt bracket is correctly mounted when you set up the rack.  For safety reasons, no m

Summary of the content on the page No. 20

Environmental Protection Important Notes 2.8 Environmental Protection Environmentally friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and devel- opment”. This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to


Alternative user manuals
# User manual Category Download
1 Fujitsu Siemens Computers AC Adapter FMWAC6B User manual Network Card 1
2 Fujitsu Siemens Computers AC Adapter FMWAC6A User manual Network Card 1
3 Fujitsu Siemens Computers Screen Protector FMWSP8 User manual Network Card 1
4 Fujitsu Siemens Computers Connectivity Peripherals Point 500 User manual Network Card 2
5 Fujitsu Siemens Computers Serial Adapter FMW43SA01 User manual Network Card 1
6 Fujitsu Siemens Computers AC Adapter FMWAC6C User manual Network Card 1
7 Fujitsu Siemens Computers Connectivity Peripherals Point 1600 User manual Network Card 0
8 Fujitsu Siemens Computers Stylistic LT Series User manual Network Card 2
9 Sony BTA-NW1A User manual Network Card 2
10 Sony BKMW-E3000 User manual Network Card 2
11 Sony AC-SQ950D User manual Network Card 0
12 Sony BBV RX100 User manual Network Card 3
13 Sony CLIE A-AVZ-100-11 User manual Network Card 1
14 Sony BTA-NW1 User manual Network Card 11
15 Sony AC-NWUM50 User manual Network Card 1