Inhaltszusammenfassung zur Seite Nr. 1
HARDWARE
GUIDE
®
MegaRAID SCSI 320-2
RAID Controller
November 2002
®
Inhaltszusammenfassung zur Seite Nr. 2
This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. LSI Logic products are not intended for use in life-support appliances, devices, or systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited. Document DB15-000259-00, First Edition (Novembe
Inhaltszusammenfassung zur Seite Nr. 3
FCC Regulatory Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's author- ity to operate the equipment. This equipment has been tested
Inhaltszusammenfassung zur Seite Nr. 4
iv Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Inhaltszusammenfassung zur Seite Nr. 5
Preface This book is the primary reference and Hardware Guide for the LSI Logic ® MegaRAID SCSI 320-2 Controller. It contains instructions for installing the MegaRAID controller and for configuring RAID arrays. It also contains background information on RAID. The MegaRAID SCSI 320-2 controller supports single-ended and low- voltage differential (LVD) SCSI devices on two Ultra320 and Wide SCSI channels with data transfer rates up to 320 Mbytes/s. Audience This document is intended for people who n
Inhaltszusammenfassung zur Seite Nr. 6
• Chapter 6, Hardware Installation, explains how to install the MegaRAID SCSI 320-2 controller. • Chapter 7, Installing and Configuring Clusters, explains how to implement clustering to enable two independent servers to access the same shared data storage. • Chapter 8, Troubleshooting, provides troubleshooting information for the MegaRAID SCSI 320-2 controller. • Appendix A, SCSI Cables and Connectors, describes the SCSI cables and connectors used with the MegaRAID SCSI 320-2 controller. • Append
Inhaltszusammenfassung zur Seite Nr. 7
MegaRAID Problem Report Form (Cont.) System Information Motherboard: BIOS manufacturer: Operating System: BIOS Date: Op. Sys. Ver.: Video Adapter: MegaRAID CPU Type/Speed: Driver Ver.: Network Card: System Memory: Other disk controllers Other adapter cards installed: Installed: Description of problem: Steps necessary to re-create problem: 1. 2. 3. 4. Preface vii Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Inhaltszusammenfassung zur Seite Nr. 8
Logical Drive Configuration Use this form to record the configuration details for your logical drives. Logical Drive Configuration Logical RAID Stripe Logical Drive Cache Read Write # of Physical Drive Level Size Size Policy Policy Policy Drives LD0 LD1 LD2 LD3 LD4 LD5 LD6 LD7 LD8 LD9 LD10 LD11 LD12 LD13 LD14 LD15 LD16 LD17 LD18 LD19 LD20 LD21 viii Preface Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Inhaltszusammenfassung zur Seite Nr. 9
Logical Drive Configuration (Cont.) Logical RAID Stripe Logical Drive Cache Read Write # of Physical Drive Level Size Size Policy Policy Policy Drives LD22 LD23 LD24 LD25 LD26 LD27 LD28 LD29 LD30 LD31 LD32 LD33 LD34 LD35 LD36 LD37 LD38 LD39 Preface ix Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Inhaltszusammenfassung zur Seite Nr. 10
Physical Device Layout Use this form to record the physical device layout. Physical Device Layout Channel 0 Channel 1 Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware
Inhaltszusammenfassung zur Seite Nr. 11
Physical Device Layout (Cont.) Channel 0 Channel 1 Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number F
Inhaltszusammenfassung zur Seite Nr. 12
Physical Device Layout (Cont.) Channel 0 Channel 1 Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Target ID Device type Logical drive number/Drive number Manufacturer/Model number F
Inhaltszusammenfassung zur Seite Nr. 13
Physical Device Layout (Cont.) Channel 0 Channel 1 Target ID Device type Logical drive number/Drive number Manufacturer/Model number Firmware level Preface xiii Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Inhaltszusammenfassung zur Seite Nr. 14
xiv Preface Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Inhaltszusammenfassung zur Seite Nr. 15
Contents Chapter 1 Overview 1.1 SCSI Channels 1-1 1.2 NVRAM and Flash ROM 1-2 1.3 SCSI Connectors 1-2 1.4 Single-Ended and Differential SCSI Buses 1-2 1.5 Maximum Cable Length for SCSI Standards 1-2 1.6 SCSI Bus Widths and Maximum Throughput 1-3 1.7 Documentation 1-3 1.7.1 MegaRAID SCSI 320-2 Hardware Guide 1-4 1.7.2 MegaRAID Configuration Software Guide 1-4 1.7.3 MegaRAID Operating System Driver Installation Guide 1-4 Chapter 2 Introduction to RAID 2.1 RAID Benefits 2-1 2.1.1 Improved I/O 2-1 2.1
Inhaltszusammenfassung zur Seite Nr. 16
2.3.7 Disk Spanning 2-7 2.3.8 Parity 2-8 2.3.9 Hot Spares 2-8 2.3.10 Hot Swapping 2-9 2.3.11 Disk Rebuild 2-9 2.3.12 Logical Drive States 2-10 2.3.13 SCSI Drive States 2-10 2.3.14 Disk Array Types 2-11 2.3.15 Enclosure Management 2-11 Chapter 3 RAID Levels 3.1 Selecting a RAID Level 3-1 3.2 RAID 0 3-2 3.3 RAID 1 3-3 3.4 RAID 5 3-4 3.5 RAID 10 3-6 3.6 RAID 50 3-7 Chapter 4 Features 4.1 SMART Technology 4-3 4.2 Configuration on Disk 4-3 4.3 Configuration Features 4-3 4.4 Array Performance Features 4
Inhaltszusammenfassung zur Seite Nr. 17
4.10.7 SCSI Connectors 4-10 4.10.8 SCSI Termination 4-10 4.10.9 SCSI Firmware 4-10 4.11 RAID Management 4-11 4.11.1 MegaRAID BIOS Configuration Utility 4-11 4.11.2 WebBIOS Configuration Utility 4-11 4.11.3 Power Console Plus 4-12 4.11.4 MegaRAID Manager 4-12 4.12 Compatibility 4-12 4.12.1 Server Management 4-12 4.12.2 SCSI Device Compatibility 4-12 4.12.3 Software 4-12 Chapter 5 Configuring Physical Drives, Arrays, and Logical Drives 5.1 Configuring SCSI Physical Drives 5-1 5.1.1 Distributing Drives
Inhaltszusammenfassung zur Seite Nr. 18
6.2.1 Step 1: Unpack 6-3 6.2.2 Step 2: Power Down 6-3 6.2.3 Step 3: Install Cache Memory 6-4 6.2.4 Step 4: Check Jumper Settings 6-5 6.2.5 Step 5: Set Termination 6-8 6.2.6 Step 6 Set SCSI Terminator Power 6-13 6.2.7 Step 7: Install Battery Pack (Optional) 6-13 6.2.8 Step 8: Install MegaRAID SCSI 320-2 6-16 6.2.9 Step 9: Connect SCSI Devices 6-17 6.2.10 Step 10: Set Target IDs 6-18 6.2.11 Step 11: Power Up 6-20 6.2.12 Step 12: Run the MegaRAID BIOS Configuration Utility 6-20 6.2.13 Step 13: Insta
Inhaltszusammenfassung zur Seite Nr. 19
7.4.13 Verifying Disk Access and Functionality 7-15 7.4.14 Installing Cluster Service Software 7-16 7.4.15 Configuring Cluster Disks 7-18 7.4.16 Validating the Cluster Installation 7-25 7.4.17 Configuring the Second Node 7-25 7.4.18 Verifying Installation 7-26 7.5 Installing SCSI Drives 7-27 7.5.1 Configuring the SCSI Devices 7-28 7.5.2 Terminating the Shared SCSI Bus 7-28 Chapter 8 Troubleshooting 8.1 General Troubleshooting 8-1 8.2 BIOS Boot Error Messages 8-3 8.3 Other BIOS Error Messages 8-5 8.
Inhaltszusammenfassung zur Seite Nr. 20
Index Customer Feedback xx Contents Copyright © 2002 by LSI Logic Corporation. All rights reserved.