Inhaltszusammenfassung zur Seite Nr. 1 
                    
                        INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGES
with standard clean oven
Table of Contents
RANGE SAFETY............................................................................................................ 2
INSTALLATION REQUIREMENTS............................................................................... 3
Tools and Parts........................................................................................................... 3
Location Requirements.................
                    
                    Inhaltszusammenfassung zur Seite Nr. 2 
                    
                        RANGE SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediately  DANG
                    
                    Inhaltszusammenfassung zur Seite Nr. 3 
                    
                        In the State of Massachusetts, the following installation instructions apply: ■  Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by  the State of Massachusetts. ■  If using a ball valve, it shall be a T-handle type. ■  A flexible gas connector, when used, must not exceed 3 feet. WARNING Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip
                    
                    Inhaltszusammenfassung zur Seite Nr. 4 
                    
                        Location Requirements IMPORTANT: Observe all governing codes and ordinances. Do  Mobile Home - Additional Installation Requirements not obstruct flow of combustion and ventilation air.  The installation of this range must conform to the Manufactured  Home Construction and Safety Standard, Title 24 CFR, Part 3280  ■ It is the installer’s responsibility to comply with installation  (formerly the Federal Standard for Mobile Home Construction  clearances specified on the model/serial rating plate. T
                    
                    Inhaltszusammenfassung zur Seite Nr. 5 
                    
                        Cabinet Dimensions Electrical Requirements Cabinet opening dimensions shown are for 25" (64.0 cm)  countertop depth, 24" (61.0 cm) base cabinet depth and WARNING 36" (91.4 cm) countertop height. If the cabinet depth is greater than 24" (61.0 cm), oven frame  must extend beyond cabinet fronts by ½" (13.0 mm) minimum. IMPORTANT: If installing a range hood or microwave hood  combination above the range, follow the range hood or  microwave hood combination installation instructions for  dimensional 
                    
                    Inhaltszusammenfassung zur Seite Nr. 6 
                    
                        Gas Supply Requirements Flexible metal appliance connector: ■ If local codes permit, a new CSA design-certified,  WARNING 4 to 5 ft (122 to 152.4 cm) long, ½" (1.3 cm) or  ¾" (1.9 cm) I.D., flexible metal appliance connector may  be used for connecting range to the gas supply line.  Explosion Hazard ■ A ½" (1.3 cm) male pipe thread is needed for connection  to the female pipe threads of the inlet to the appliance  Use a new CSA International approved gas supply line. pressure regulator.  Install
                    
                    Inhaltszusammenfassung zur Seite Nr. 7 
                    
                        Line pressure testing above ½ psi gauge (14" WCP) Burner Input Requirements The range and its individual shutoff valve must be disconnected  from the gas supply piping system during any pressure testing of  Input ratings shown on the model/serial rating plate are for  that system at test pressures in excess of ½ psi (3.5 kPa). elevations up to 2,000 ft (609.6 m).  Line pressure testing at ½ psi gauge (14" WCP) or lower For elevations above 2,000 ft (609.6 m), ratings are reduced at a  The range 
                    
                    Inhaltszusammenfassung zur Seite Nr. 8 
                    
                        If cabinet opening is wider than that specified in the “Location 7. Move range close enough to the opening to allow for final  Requirements” section, adjust template so range will be  electrical connection. Remove shipping base, cardboard or  centered in cabinet opening. hardboard from under range. 8. Open the broiler door. Use a ³⁄₈" drive ratchet to lower the rear  5. To mount anti-tip bracket to wood floor, drill two ¹⁄₈" (0.32 cm)  leveling legs one-half turn. Use a wrench or pliers to lower
                    
                    Inhaltszusammenfassung zur Seite Nr. 9 
                    
                        Make Gas Connection 3. Use a combination wrench and pliers to attach the flexible  connector to the adapters. Check that connector is not  WARNING kinked.    A B D Explosion Hazard C Use a new CSA International approved gas supply line. Install a shut-off valve. F E Securely tighten all gas connections. G If connected to LP, have a qualified person make sure  gas pressure does not exceed 14" (36 cm) water  H column.  Examples of a qualified person include: A. Pressure regulator E. Adapter connec
                    
                    Inhaltszusammenfassung zur Seite Nr. 10 
                    
                        5. Close the broiler door. 6. Remove cooktop burner caps and grates from parts  Electronic Ignition System package. Align notches in burner caps with pins in burner  Initial lighting and gas flame adjustments base. Burner caps should be level when properly positioned.  Cooktop and oven burners use electronic igniters in place of  If burner caps are not properly positioned, surface burners  standing pilots. When the cooktop control knob is turned to the  will not light. Place burners, burner caps
                    
                    Inhaltszusammenfassung zur Seite Nr. 11 
                    
                        2. Insert a small flat-blade screwdriver into the valve stem. Turn 3. Locate the air shutter near the rear wall of oven and loosen  the valve adjusting screw to obtain the smallest flame that will the shutter screw. not go out when the control of a cold burner is quickly turned  from “HI” to “Lo.” Turn right to decrease flame height. Turn  A left to increase flame height. Repeat for other cooktop  burners as needed. B A. Shutter screw B. Air shutter 4. Adjust the air shutter. A 5. Turn the oven 
                    
                    Inhaltszusammenfassung zur Seite Nr. 12 
                    
                        GAS CONVERSIONS 2. Unplug range or disconnect power. 3. Open broiler door and remove broiler pan. The gas pressure  WARNING regulator is located in the back right hand corner of the broiler  compartment. A Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. A. Gas pressure regulator Securely tighten all gas connections. IMPORTANT: Do not remove the gas pressure regulator. If connected to LP, have a qualified person make sure  4. Remove the cap from th
                    
                    Inhaltszusammenfassung zur Seite Nr. 13 
                    
                        For models with 3 standard burners and 1 super™ burner: To Convert Surface Burners 1. Remove burner grate, burner caps and burners.  A Std burner 88 Std burner 88 Super burner 96 Std burner 88 B 5. Place the Natural gas orifice spuds in the parts bag for future  use and keep with the bag containing literature. 6. Reinstall burners, burner caps and burner grates. A. Burner cap To Convert Oven Burner B. Burner 1. Open the oven door and remove oven racks, oven tray, flame  2. Locate LP gas orifice 
                    
                    Inhaltszusammenfassung zur Seite Nr. 14 
                    
                        3. Open broiler door and remove broiler pan. The gas pressure  regulator is located in the back right hand corner of the broiler  Complete Conversion compartment. 1. Refer to the “Make Gas Connection” section for properly  connecting the range to the gas supply. 2. Turn the manual shutoff valve in the gas supply line to the  A open position. 3. Refer to “Check Operation” in the “Electronic Ignition  System” section for proper burner ignition, operation and  burner flame adjustments. IMPORTANT: Y
                    
                    Inhaltszusammenfassung zur Seite Nr. 15 
                    
                        For models with 4 standard burners: To Convert Surface Burners 1. Remove burner grate, burner caps and burners.  A Std Burner 149 Std Burner 149 Std Burner 149 Std Burner 149 B For models with 3 standard burners and 1 super burner: A. Burner cap B. Burner Std Burner 149 Std Burner 149 2. Locate the Natural gas orifice spuds for top burners in the  literature bag included with the range. Three natural gas  spuds are stamped “149” and one “165.” Std Burner 149 Super Burner 165 3. Remove the LP gas
                    
                    Inhaltszusammenfassung zur Seite Nr. 16 
                    
                        3. Locate Natural gas orifice spud stamped “47” in the bag  containing literature supplied with the range. Complete Conversion 4. Use a ³⁄₈" combination wrench and remove the LP gas orifice  1. Refer to the “Make Gas Connection” section for properly  spud. connecting the range to the gas supply. 5. Install the number “47” LP gas spud. 2. Turn the manual shutoff valve in the gas supply line to the  open position. 3. Refer to “Check Operation” in the “Electronic Ignition  A System” section for pro