Inhaltszusammenfassung zur Seite Nr. 1
®
EH66/EH66X
Environmental Enclosures
Installation/Operation Manual
C411M-D (1/96)
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
(559) 292-1981 or (800) 289-9100 • FAX (559) 292-3827 or (800) 289-9150
Pelco Manual C411M-D (1/96) 17
Inhaltszusammenfassung zur Seite Nr. 2
TABLE OF CONTENTS Section Page 1.0 WARNINGS ........................................................................................................................................1 2.0 SCOPE ...............................................................................................................................................2 3.0 DESCRIPTION ...................................................................................................................................2 3.1 CERTIFICAT
Inhaltszusammenfassung zur Seite Nr. 3
LIST OF ILLUSTRATIONS Figure Page 1 EH66/EH66X Dimension Drawing ................................................................................................. 2 2 Wiring Diagram for Window Defroster, Wiper/Washer and Blower/Heater Assemblies................. 4 3 EH66 Enclosure with Wall Mount .................................................................................................. 5 4 EH66 Enclosure with Pedestal/Ceiling Mount ........................................................
Inhaltszusammenfassung zur Seite Nr. 4
This page intentionally left blank. iv Pelco Manual C411M-D (1/96)
Inhaltszusammenfassung zur Seite Nr. 5
INSTALLATION/OPERATION MANUAL MODEL EH66/EH66X SERIES ENVIRONMENTAL ENCLOSURES 1.0 WARNINGS Prior to installation and use of this product, the following 4. After replacement/repair of this unit’s electrical WARNINGS should be observed. components, conduct a resistance measurement between line and exposed parts to verify the exposed 1. Installation and servicing should only be done by parts have not been connected to line circuitry. Qualified Service Personnel and conform to all local codes. 5.
Inhaltszusammenfassung zur Seite Nr. 6
2.0 SCOPE date intensified cameras. The EH66X Series will accept a maximum camera/lens size of 7" W x 7" H x 30" L The information contained within this manual covers (17.7 cm x 17.7 cm x 76.2 cm). the EH66/EH66X Series environmental enclosure. Models With The Letters HB in the suffix come 3.0 DESCRIPTION equipped with a factory installed filtered blower and wired blanket heater with thermostat controls. The The EH66 Series is an all-weather environmental enclo- heater activates when the int
Inhaltszusammenfassung zur Seite Nr. 7
4.0 INSTALLATION NOTE: Cameras with a low optical centerline Please check the contents of your package(s) for the or using a large diameter lens require an eleva- following items before proceeding with the installation tion block (1 inch or 2 inch) for proper posi- of the equipment. tioning. See Section 8.0, Optional Accessories, for the correct model number. Quantity Item 3. Replace the camera/sled assembly onto the rail and 2 1/4-20 x .500 hex head screws to mount slide along the rail to adj
Inhaltszusammenfassung zur Seite Nr. 8
to control Figure 2. Wiring Diagram for Window Defroster, Wiper/Washer and Blower/Heater Assemblies 4 Pelco Manual C411M-D (1/96)
Inhaltszusammenfassung zur Seite Nr. 9
4.3 FIXED ENCLOSURE MOUNTING 3. Attach the adjustable head to the mount. The are two types of mounts that can be used with the 4. Align the 1/4-20 threaded holes in the bottom of the EH66 enclosure: wall, or pedestal/ceiling (see Figures EH66 enclosure with the holes in the tilt table of the 3 and 4). adjustable head. Fasten the enclosure to the table using 1/4-20 fasteners (not to exceed 5/8" in length, Instructions for mounting the enclosure are as follows: minimum two (2). 1. Select the appr
Inhaltszusammenfassung zur Seite Nr. 10
4.4 PAN/TILT ENCLOSURE MOUNTING 4. Attach the pan/tilt to the mount. The pan/tilt control connect should be positioned towards the building/ The EH66 enclosure can also be mounted to a pan/tilt mounting location. Note the “front” label on the assembly in addition to the wall or pedestal/ceiling pan/tilt. mount. 5. If you have not already done so, install the To include the pan/tilt assembly in your configuration, camera/lens according to the instructions in perform the following steps: Section
Inhaltszusammenfassung zur Seite Nr. 11
4.5 WINDOW WIPER INSTALLATION 8. Attach the water reservoir bottle to the rear of the EH66 enclosure by removing the two (2) top acorn To install the window wiper kit, perform the following nuts. steps and refer to Figures 7 and 8: 9. Place the bottle mount on the protruding studs and 1. Turn the EH66 enclosure over so the bottom is replace the acorn nuts. facing up. 10. Attach the water hose to the bottle from the wiper. 2. If necessary, lay out the locations of the four (4) .171-inch diameter
Inhaltszusammenfassung zur Seite Nr. 12
4.6 B66KIT/E624HB/H66KIT 5.0 CARE AND MAINTENANCE INSTALLATION Maintenance performed at regularly scheduled inter- All heater and blower kits are supplied partially as- vals will help prolong the operational life and appear- sembled. Install in the enclosure according to the fol- ance of the equipment. lowing instructions: 1. Clean the plexi-glass window with a mild nonabra- 1. Remove the round cap on the rear of the enclosure sive detergent in water and a soft cloth regularly to and the two (2
Inhaltszusammenfassung zur Seite Nr. 13
6.0 EXPLODED ASSEMBLY DIAGRAMS See Figures 9 and 10 for exploded assembly diagrams of the EH66 enclosure and WW66, WW66-5/220 wiper assembly. Figure 9. EH66 Enclosure Exploded Assembly Diagram Pelco Manual C411M-D (1/96) 9
Inhaltszusammenfassung zur Seite Nr. 14
NOTE: FIGURE DOES NOT REPRESENT CURRENT PUMP IN USE. Figure 10. WW66, WW66-5/220 Wiper Exploded Assembly Diagram 10 Pelco Manual C411M-D (1/96)
Inhaltszusammenfassung zur Seite Nr. 15
7.0 MECHANICAL PARTS LISTS 7.1 MECHANICAL AND ELECTRICAL PARTS LIST FOR EH66 ENCLOSURE Item No. Qty Description Part Number 1 4 Gasket, Window Frame EH110042 2 1 Gasket, Cable Entry EH110072 3 1 Plate, Cable Entry EH14231COMP 4 2 Gasket, Rim EH450010000 5 2 Gland, UL, PG-13.5 black EH470010007B 6 2 Nut, UL Gland, 13.5 EH470010008B 7 4 Fastener, Lid Link Lock EH550010010B 8 8 Gasket, Poron EH550010030 9 1 Camera Sled EH55004100COMP 10 1 Body Weld Assy EH661000WA 1 Body Weld Assy (EH66
Inhaltszusammenfassung zur Seite Nr. 16
7.2 MECHANICAL PARTS LIST FOR WW66 AND WW66-5/220 WINDOW WIPER ASSEMBLY Item No. Qty Description Part Number 1 3 Bearing 776003 2 1 Diode DIOPT40F 3 — Not used — 4 1 Switch SWIV3L 5 1 Spacer, 1/4" Hex x .6254-40 tap SPA8404 6 1 Transformer TRF21162.01.0CM 7 1 Pump WW6610031 8 12 Tubing, Vinyl, 1/8 ID x 1/4 OD x in. WW6610007 9 42 Tubing, Vinyl, 1/4 ID x 3/8 OD x in. WW6610005 10 1 Solenoid valve WW650010010 11 3 Spacer Shaft, #84-9 WW6610010 12 1 Roller Plate WW661006COMP 13 1 Follower Arm WW661
Inhaltszusammenfassung zur Seite Nr. 17
8.0 OPTIONAL ACCESSORIES H66KIT Heater kit, 120 VAC, for EH66/EH66X enclosures. (For 230 VAC option, wire FACTORY INSTALLED heaters in series.) EHRC Relay module for low voltage control of wiper/washer and camera on/off. L66KIT Tamper proof lock kit. Requires MEH24DT control module. S66 Sun shroud, provides an air space be- TI66 Thermal insulation provides increased tween the sun shroud and the enclosure thermal protection for enclosure and to protect the enclosure from the direct contents at e
Inhaltszusammenfassung zur Seite Nr. 18
9.1 RECOMMENDED CABLE SIZE 9.2 POWER REQUIREMENTS FOR BLOWER, HEATER, ACCESSORIES CAUTION: When a single power source is The blower, heater and electrically powered accessories used for both the camera and accessories, the use the following wattage when in operation: camera power consumption must be taken into consideration when determining the wire gauge. Blower: 24 VAC: 7.2 watts (AC rectified) 120 VAC: 13.5 watts at 60 Hz The following cable sizes are the minimum recom- 230 VAC: 15 watts at
Inhaltszusammenfassung zur Seite Nr. 19
10.0 WARRANTY AND RETURN INFORMATION PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or workmanship for a period of one year after the date of shipment. (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: Exceptions to this warranty are as noted below: 1. Model and serial nu
Inhaltszusammenfassung zur Seite Nr. 20
® Pelco 3500 Pelco Way, Clovis, CA 93612-5699 • (559) 292-1981 • (800) 289-9100 FAX (559) 292-3827 • (800) 289-9150 • www.pelco.com International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.) C411M-D 16 Pelco Manual C411M-D (1/96)