Inhaltszusammenfassung zur Seite Nr. 1
Sun StorageTek ATCA 4Gb FC Dual
Port HBA
Installation Guide For HBA Models
SG-XPCIE2FC-ATCA-Z, SG-PCIE2FC-ATCA-Z,
SG-XPCIE2FC-ATCA-N, and SG-PCIE2FC-ATCA-N
Part No. 820-2217-13
April 2010, Revision A
Inhaltszusammenfassung zur Seite Nr. 2
Copyright © 2008, 2010, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reve
Inhaltszusammenfassung zur Seite Nr. 3
Contents Preface v 1. HBA Overview 1 Kit Contents 1 HBA Features and Specifications 1 Operating System Requirements 3 System Interoperability 3 Host Platform Support 4 Storage System Support 4 Fibre Channel Switch Support 4 Software Support 5 2. Hardware Installation and Removal 7 Observing ESD and Handling Precautions 7 Installing the Hardware 8 ▼ To Verify the PPS Shelf Manager Firmware Version 8 ▼ To Install the HBA 8 ▼ To Connect the Optical Cable 10 ▼ To Verify the Installation (Solaris OS)
Inhaltszusammenfassung zur Seite Nr. 4
Removing the Hardware 15 ▼ To Prepare the HBA for Hot-Plug Removal Using the Module Handle 15 ▼ To Prepare the HBA for Hot-Plug Removal (Solaris OS) 15 ▼ To Remove the HBA Hardware 16 3. HBA Software Installation 17 Installing Software for the Solaris OS 17 ▼ To Install or Update the Driver From a Patch 17 Solaris Diagnostic Support 18 Installing Software for the Wind River Linux OS 18 ▼ To Obtain the Wind River Development Kit 18 Installing Software for the Red Hat Enterprise Linux OS 19 ▼ To I
Inhaltszusammenfassung zur Seite Nr. 5
Preface This installation guide describes how to install and remove Oracle’s Sun StorageTek ATCA 4Gb FC dual port host bus adapter (HBA). It also explains how to verify the driver version and install any necessary patches. This document is written for technicians, system administrators, application service providers (ASPs), and users who have advanced experience troubleshooting and replacing hardware. This preface contains the following topics: ■ “Accessing Oracle Documentation” on page v ■ “Acc
Inhaltszusammenfassung zur Seite Nr. 6
Accessing Related Documentation The document listed in this section is available at: http://docs.sun.com/source/819-0139/ Title Part Number Solaris Fibre Channel and Storage Multipathing Administration Guide 819-0139 Documentation, Support, and Training Sun Function URL Documentation http://docs.sun.com Support http://www.sun.com/support/ Training http://www.sun.com/training/ Note – Prior to contacting Oracle support, record the HBA serial number in a safe location. Documentation Comments We are
Inhaltszusammenfassung zur Seite Nr. 7
CHAPTER 1 HBA Overview This chapter provides a basic overview of Oracle’s Sun StorageTek ATCA 4Gb FC Dual Port host bus adapter (HBA), which uses Emulex technology. This chapter also describes the various operating systems, host platforms, storage, and infrastructure configurations that support the HBA. This chapter contains the following topics: ■ “Kit Contents” on page 1 ■ “HBA Features and Specifications” on page 1 ■ “Operating System Requirements” on page 3 ■ “System Interoperability” on pag
Inhaltszusammenfassung zur Seite Nr. 8
TABLE 1-1 HBA Features and Specifications Feature Description AMC connector B+ PCI signaling environment PCI Express x4 (4 active lanes) PCI transfer rate (maximum) PCI Express Generation One (2.5 Gbits/sec) x4 Number of FC buses Two Number of devices supported 126 devices per FC loop; 510 devices in Fabric mode FC bus type (external) Fiber-optic media, short-wave, multi-mode fiber (400-M5- SN-S) FC transfer rate 400 MBps per port maximum, half-duplex 800 MBps per port maximum, full-duplex RAM 1
Inhaltszusammenfassung zur Seite Nr. 9
Operating System Requirements The HBA requires the operating system (OS) levels, at minimum, listed in TABLE 1-2. TABLE 1-2 Supported Operating System Versions Operating System Supported Versions (minimum) Solaris 10 OS for Solaris 10 8/07 (s10u4), 11/06 (s10u3), 6/06 (s10u2), and 1/06 (s10u1) * the x64 and x86 and latest patches 119131 and 120223 platform † Solaris 10 First Customer Shipment (FCS), packages SUNWemlxs and SUNWemlxu and latest patches 119255, 119131, and 120223 Solaris 10 OS for
Inhaltszusammenfassung zur Seite Nr. 10
Host Platform Support The HBA is supported by the platforms and operating systems (OSs) listed in TABLE 1-3. TABLE 1-3 Platform and Operating System Support Platform Supported OS * Netra™ ACTA 3060 and 3220 Solaris, Linux servers * See TABLE 1-2 for specific OS versions. The system must have an available AdvancedMC slot in which you can install the HBA. Storage System Support The HBA supports the following storage systems: ■ Sun StorageTek 2540 FC array ■ Sun StorEdge 3510 and 3511 FC arrays (RA
Inhaltszusammenfassung zur Seite Nr. 11
■ 10 Gb Brocade M6140 Director ■ 10 Gb Brocade Mi10K Director ■ 2 Gb McDATA Sphereon 4300 switch ■ 2 Gb McDATA Sphereon 4500 switch ■ 2 Gb McDATA Intrepid 6064 Director ■ 4 Gb McDATA Sphereon 4400 and 4700 switches ■ Cisco MDS 9120 Fabric switch ■ Cisco MDS 9124 24-Port Multilayer Fabric switch ■ Cisco MDS 9140 Fabric switch ■ Cisco MDS 9216A Multilayer Fabric switch ■ Cisco MDS 9216i Multilayer Fabric switch ■ Cisco MDS 9509 Multilayer Director ■ Cisco MDS 9513 Multilayer Director Software Supp
Inhaltszusammenfassung zur Seite Nr. 12
6 Sun StorageTek ATCA 4Gb FC Dual Port HBA Installation Guide • April 2010
Inhaltszusammenfassung zur Seite Nr. 13
CHAPTER 2 Hardware Installation and Removal This chapter describes the tasks required to install and remove the HBA. Refer to your system installation or service manual for detailed instructions. This chapter contains the following topics: ■ “Observing ESD and Handling Precautions” on page 7 ■ “Installing the Hardware” on page 8 ■ “To Verify the Installation (Solaris OS)” on page 13 ■ “Removing the Hardware” on page 15 Observing ESD and Handling Precautions Caution – Damage to the HBA can occur
Inhaltszusammenfassung zur Seite Nr. 14
■ Place the HBA on a properly grounded antistatic work surface pad when it is out of its protective antistatic bag. Installing the Hardware The hardware installation process involves the following general steps: ■ “To Verify the PPS Shelf Manager Firmware Version” on page 8 ■ “To Install the HBA” on page 8 ■ “To Connect the Optical Cable” on page 10 The following sections describe these steps in more detail. ▼ To Verify the PPS Shelf Manager Firmware Version If you are using Oracle’s Sun Netra C
Inhaltszusammenfassung zur Seite Nr. 15
FIGURE 2-1 Removing the AMC Slot Filler Panel Note – A module handle is at the bottom of the HBA. When you install the HBA, the position of the module handle (pulled out or pushed in) does not matter. 3. Insert the HBA through the cutout and into the AMC slot (FIGURE 2-2). Chapter 2 Hardware Installation and Removal 9
Inhaltszusammenfassung zur Seite Nr. 16
FIGURE 2-2 Inserting the HBA Into the AMC Connector 4. Carefully plug the HBA into the AMC connector (FIGURE 2-2). Ensure that the HBA is seated correctly in the connector. Caution – Do not use excessive force when installing the HBA into the slot. You might damage the AMC connector on the Netra board, causing permanent damage to the HBA or board. If the HBA does not seat properly when you apply even pressure, remove the HBA and carefully reinstall it. 5. If the module handle was pulled out when
Inhaltszusammenfassung zur Seite Nr. 17
TABLE 2-1 Optical Cable Specifications Fiber-Optic Cable Maximum Length Minimum Length Connector 62.5/125µm 300 meters at 1.0625 Gbps 2 meters LC (multimode) 150 meters at 2.125 Gbps 70 meters at 4.25 Gbps 50/125µm 500 meters at 1.0625 Gbps 2 meters LC (multimode) 300 meters at 2.125 Gbps 150 meters at 4.25 Gbps Follow these steps when connecting the optical cable: 1. Connect the fiber-optic cable to an LC connector on the HBA as shown in FIGURE 2-3. FIGURE 2-3 Connecting the Optical Cables 2. C
Inhaltszusammenfassung zur Seite Nr. 18
3. Observe the port LEDs status for the power-on self test (POST) results as shown in TABLE 2-2. TABLE 2-2 summarizes port LED indicator combinations. Refer to FIGURE 2-4 to determine the location of the LEDs. Each port has a corresponding set of LEDs that provide a visual indication of the operating state. TABLE 2-2 Port LED Indicator Status Definitions Green LED Yellow LED State On 1 fast blink 1-Gb link rate - Normal operating state, link up On 2 fast blinks 2-Gb link rate - Normal operating
Inhaltszusammenfassung zur Seite Nr. 19
FIGURE 2-4 LEDs ▼ To Verify the Installation (Solaris OS) 1. Use the cfgadm command to verify proper HBA installation. % cfgadm Ap_Id Type Receptacle Occupant Condition c3 fc connected configured ok c4 fc connected configured ok pcie5 fibre/hp connected configured ok If the HBA is properly installed and connected, you will see output similar to that shown in the example. 2. If an HBA adapter is shown as unconfigured o
Inhaltszusammenfassung zur Seite Nr. 20
▼ To Verify Attached Storage (Solaris OS) 1. Use the cfgadm -al command to verify attached storage. % cfgadm -al Ap_Id Type Receptacle Occupant Condition c3 fc-fabric connected configured unknown c3::200600a0b816005e disk connected configured unknown c3::200700a0b816005e disk connected configured unknown c4 fc connected unconfigured unknown pcie5 fibre/hp connected configured ok If the HBA is properly installed and storage is connected properly, you will see output simi