Resumen del contenido incluido en la página 1 
                    
                         
ProLiant BL p-Class GbE2 Interconnect Switch Overview 
white paper 
 
Abstract.............................................................................................................................................. 3 
Introduction......................................................................................................................................... 3 
GbE2 Interconnect Kit ...................................................................................................
                    
                    Resumen del contenido incluido en la página 2 
                    
                        Enterprise-class performance ............................................................................................................... 16  Network adapter teaming................................................................................................................... 16  Conclusion........................................................................................................................................ 17  Appendix: Summary of features of the ProLiant BL p-Class GbE2
                    
                    Resumen del contenido incluido en la página 3 
                    
                        Abstract  This white paper provides an overview of the second generation Gigabit Ethernet (GbE2) Interconnect  Kit options for the ProLiant BL p-Class system. Each GbE2 Interconnect Kit includes a pair of industry- standard Ethernet switches that dramatically reduce the number of Ethernet network cables attached to  the rear of the ProLiant BL p-Class server blade enclosure. When the GbE2 Interconnect Kit is used  with the optional GbE2 Storage Connectivity Kit, it also provides pass-through of 
                    
                    Resumen del contenido incluido en la página 4 
                    
                        GbE2 Interconnect Kit  The GbE2 Interconnect Kit contains two redundant, hot-swappable GbE2 Interconnect Switches and  two 4-port LAN interconnect modules. Users first insert the LAN interconnect modules into the bottom- left and bottom-right interconnect bays at the rear of the server blade enclosure and then install the  interconnect switches into the interconnect bays from the front of the enclosure (Figure 1). The GbE2  Interconnect Switches consolidate the 32 Ethernet ports from the server 
                    
                    Resumen del contenido incluido en la página 5 
                    
                        redundant fans and they are powered by two independent feeds via the redundant, N+N hot-plug  ProLiant BL p-Class power enclosure.  Users can independently disable or enable the switch ports as desired. Auto-MDI/MDIX with auto- negotiation of speed and duplex mode is supported. Each GbE2 Interconnect Switch includes the  following Ethernet ports:  • Sixteen dedicated internal 10/100/1000 Mb/s Ethernet downlink ports connecting the server  NICs to the switch.  • Six external Ethernet ports for da
                    
                    Resumen del contenido incluido en la página 6 
                    
                        LAN interconnect module uplink ports  The LAN interconnect module uplink ports are typically used to connect the interconnect switches to  the network infrastructure; however, they are standard Ethernet switch ports and may be used as  desired. The GbE2 interconnect kits are identical with exception of the LAN interconnect modules. The  C-GbE2 Interconnect kit includes two QuadT2 interconnect modules, each with four 10/100/1000T  Ethernet ports with RJ-45 connectors. The F-GbE2 Interconnect Kit 
                    
                    Resumen del contenido incluido en la página 7 
                    
                        module that contain a 10-Gb Ethernet high-bandwidth uplink. The 10-Gb LAN interconnect modules  may also contain Gigabit Ethernet ports, if space permits.  With these future planned options for the GbE2 Interconnect Switch, an administrator will be able to  independently select the switching layer as well as the uplink bandwidth, all within a single switch.  Both options can be installed by users in the field without powering down the server blades or the  server blade enclosure. Availability of
                    
                    Resumen del contenido incluido en la página 8 
                    
                        Applications that utilize a single uplink port include testing and evaluation systems, server blade  enclosures with a few installed servers, and applications that require minimal bandwidth. On a  heavily utilized system, using a single uplink port for all 32 network adapters can cause a traffic  bottleneck. For example, using one uplink from interconnect switch A requires the traffic from all the  network adapters routed to switch B to travel over the two crosslinks (a 2000 Mb/s path), previous
                    
                    Resumen del contenido incluido en la página 9 
                    
                        Fibre Channel pass-through  The GbE2 Interconnect Kits offer the ability to pass-through BL20p G2 Fibre Channel signals using the  optional GbE2 Storage Connectivity Kit. Therefore, both Ethernet LAN signal consolidation and Fibre  Channel SAN signal pass-through is now possible with a single interconnect. The GbE2 Interconnect  Switch chassis is simply used as a carrier to pass-through the Fibre Channel signals. The Ethernet LAN  and the Fibre Channel SAN signals are completely isolated from ea
                    
                    Resumen del contenido incluido en la página 10 
                    
                          Figure 5. BL20p G2 Fibre Channel signal routing with the GbE2 Interconnect Switch      With the GbE2 Storage Connectivity Kit installed, both Fibre Channel SAN and Ethernet LAN signals  exit the rear of the server blade enclosure, each type of signal on its dedicated interconnect module  (Figure 6). Just like the LAN QuadT2 and QuadSX interconnect modules, the SAN OctalFC  interconnect module has a robust connector assembly and includes a guide pin to ensure that the  module is properly aligne
                    
                    Resumen del contenido incluido en la página 11 
                    
                        Switch management  The GbE2 Interconnect Switch is an industry-standard managed Ethernet switch, which means that  users configure and manage the switch like other industry-standard Ethernet switches. To aid users  during initial deployment, the GbE2 Interconnect Switch includes a default configuration that is fully  operational at initial boot and a step-by-step set-up utility for custom configurations.  A web browser-based interface (BBI) and a command line interface (CLI) with scripting capab
                    
                    Resumen del contenido incluido en la página 12 
                    
                        configuration file. The configuration file has a text-based format, which allows it to be directly viewed,  printed, and edited. Each GbE2 Interconnect Switch has three configuration settings in memory  (active, back-up, and factory); any one of these settings can be selected as the current runtime  version.  Users can perform firmware operating system upgrades by using TFTP through any external Ethernet  port after boot-up, and by using XModem through the serial interface during boot-up. Redund
                    
                    Resumen del contenido incluido en la página 13 
                    
                          Scriptable command line interface  The CLI provides the added benefits of scripting, a set-up utility and other enhanced switch  management tasks, an out-of-band connection, and more. The main menu opens after a successful log- in (Figure 9). This interface may be accessed locally via the front panel RS-232 console port on each  interconnect switch or remotely using a console Telnet session via any interconnect switch external  Ethernet port.    Figure 9. Command line interface for ProLiant BL
                    
                    Resumen del contenido incluido en la página 14 
                    
                        • Specify the IP-based management networks that are allowed to access each switch.  • Set a user interface idle time-out period and disable web-based and Telnet access.  • Enable a secure shell (SSH) session to the CLI interface.  • Modify default Telnet and HTTP server socket port numbers.  Additional switch security measures include:  • RADIUS RFC 2865 to provide user authentication and authorization.  • Port-based IEEE 802.1Q tagged VLANs for server grouping and data isolation.  • Secure copy
                    
                    Resumen del contenido incluido en la página 15 
                    
                          The optional HP Diagnostic Station (Figure 11) is available to configure and diagnose an interconnect  switch or a server blade that has been removed from the server blade enclosure. The Diagnostic  Station provides power to the interconnect switch and can be used to perform any of the following  tasks:  • Build the initial interconnect switch configuration.  • Download a switch configuration file.  • Test network adapter and interconnect switch port activity.  • Diagnose interconnect switch s
                    
                    Resumen del contenido incluido en la página 16 
                    
                        • The ability to set the interconnect switch to a valid firmware image in case of firmware corruption.  For more detailed information on the administration capabilities of the ProLiant BL p-Class GbE2  6 Interconnect Switch, see the ProLiant BL p-Class GbE2 Interconnect Switch user guides.  Virtual LAN  The GbE2 Interconnect Switch supports 255 port-based IEEE 802.1Q virtual LANs (VLANs). Members  of a VLAN may be untagged and tagged ports according to IEEE 802.3ac VLAN Ethernet frame  extension
                    
                    Resumen del contenido incluido en la página 17 
                    
                        • Network Fault Tolerance (NFT)  • Transmit Load Balancing (TLB)  • Switch-assisted Load Balancing (SLB)  When teaming HP NC series network adapters with the interconnect switch, NFT and TLB teaming are  the same as with any ProLiant system. However, for SLB teaming, the pre-defined switch-to-server  architecture across the server blade enclosure’s backplane must be considered. SLB requires that all  NICs in the team must be connected to the same switch.   The GbE2 Interconnect Switch’s redundan
                    
                    Resumen del contenido incluido en la página 18 
                    
                        Appendix: Summary of features of the ProLiant BL p-Class  GbE2 Interconnect Kit  Switch performance  • Store and forward mode layer 2 switching standard  • Layer 3 routing firmware future internal upgrade capability  • Layer 7 routing and content delivery switching future internal upgrade capability  • Support for 3rd party external layer 7 content delivery switch / appliance  • Support for F5 BIG-IP Blade Controller load balancer and traffic management   • Frame forwarding throughput of 1.488 m
                    
                    Resumen del contenido incluido en la página 19 
                    
                        • MAC address user management sorting on a per port and per VLAN basis  • Manual, or automatic IP settings via a BOOTP server  • Three switch configuration settings in memory (active, back-up, and factory); any can be selected as the current version.  • Redundant firmware images in memory; either image can be selected as the current runtime version.  • Ability to restore switch to factory default settings  • TFTP and SCP to upload and download (save, restore, and update) the switch configuration
                    
                    Resumen del contenido incluido en la página 20 
                    
                        • State information ”dump” for tuning and debugging switch performance available in uuencoded format   • Panic command for immediate state dump to flash memory and automatically switch reboot  Switch security  • Password protected multi-level user accounts supported on all management interfaces  • Configurable user interface idle time-out period  • Ability to disable web-based and Telnet access to the switch user interfaces  • 255 Port-based IEEE 802.1Q tagged VLANs per switch (510 per server bl