Resumen del contenido incluido en la página 1
571209-YTG-C-1012
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It i76s designed with a matching indoor coil com-
ponent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
TECHNICAL GUIDE
• Small Footprint - The compact footprint is a perfect fit for
any application.
LX SERIES
• Quality Condenser Coils - The coil is constructed
Resumen del contenido incluido en la página 2
571209-YTG-C-1012 Physical and Electrical Data YHJD18 YHJD24 YHJD30 YHJD36 YHJD42 YHJD48 YHJD60 MODEL S41S2 S41S4 S41S4 S41S4 S41S4 S41S4 S41S5 Unit Supply Voltage 208-230V, 1 60Hz 1 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 11.9 11.2 14.1 19.7 20.9 25.6 42.6 2 20 15 20 30 35 45 70 Max. Overcurrent Device Amps 3 15 15 15 20 25 30 45 Min. Overcurrent Device Amps Compressor Type Scroll Recip Recip Recip Recip Recip Scroll Rated Load 9.0 8.3 10.6 14.7 15.7 19.4 33.0 Compressor
Resumen del contenido incluido en la página 3
571209-YTG-C-1012 System Charge for Various Matched Systems Outdoor Unit YHJD18S41S2 YHJD24S41S4 YHJD30S41S4 YHJD36S41S4 YHJD42S41S4 YHJD48S41S4 YHJD60S41S5 1,2 .051/4F1 .054, .059/4G1 .063/4G1 .071/4H1 .075/4H1 4J1 4K1 Required Orifice or TXV 3,4,5 Additional Charge, Oz Indoor Unit AHE18B .051/ TXV + 0 – – – – – – AHE24B – .054 / TXV + 0 – – – – – AHE30B – .054 / TXV + 0 .063 / TXV + 0 – – – – AHE36C – – .063 / TXV + 25 .071 / TXV + 0 – – – AHE42D – – – .071 / TXV + 16 – – – AHE48D – – – – .0
Resumen del contenido incluido en la página 4
571209-YTG-C-1012 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER HP WITH AIR HANDLERS AHE18B 17.5 – 610 18.0 14.6 14.00 12.00 AHR18B 17.5 – 665 18.0 14.9 13.00 11.00 AHV18B 17.5 – 615 18.0 13.2 14.00 12.00 AV*24 17.5 – 610 18.0 13.7 14.50 12.00 MV12B 17.5 FC/MC18B 600 18.0 13.7 14.50 12.00 YHJD18S41S2 MV12B 17.5 FC/MC24B 600 18.0 13.7 14.50 12.00 MV12B 17.5 FC/MC30B 600 18.0 13.7 14.50 12.00 MX12B 1
Resumen del contenido incluido en la página 5
571209-YTG-C-1012 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER HP WITH AIR HANDLERS AHE48D 24.5 – 1385 40.5 33.2 14.00 12.00 AHR48D 24.5 – 1320 39.5 29.6 13.00 11.00 AHV48D 24.5 – 1300 39.5 30.2 13.75 11.50 AV*48 24.5 – 1385 42.0 32.6 14.50 12.00 YHJD42S41S4 AV*60 24.5 – 1360 42.0 32.6 14.50 12.00 MV16C 21.0 FC60C 1400 40.0 30.0 13.50 11.75 MV20D 24.5 FC/MC60D 1400 42.0 32.4 14.00 12.0
Resumen del contenido incluido en la página 6
571209-YTG-C-1012 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings) COIL COOLING CFM RANGE NET MBH UNIT MODEL RATED 1 (Min.-max.) MODEL WIDTH SEER EER CFM TOTAL SENS. 13 SEER HP COIL ONLY RATINGS FC/MC/PC18 14.5,17.5 450 - 750 600 18.0 14.0 13.00 11.00 FC/MC/PC24 14.5,17.5 450 - 750 600 18.0 14.0 13.50 11.00 YHJD18S41S2 FC/MC/PC30 14.5,17.5 450 - 750 600 18.0 13.7 13.00 11.00 UC24 14.5,17.5 450 - 750 600 18.0 13.8 13.05 11.00 UC30 14.5,17.5 450 - 750 600 18
Resumen del contenido incluido en la página 7
571209-YTG-C-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL Net MBH 1 RATED MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)X*A12 14.5 UC24B 570 18.0 14.1 14.50 12.00 T*(8,L)X*A12 14.5 UC30B 570 18.0 14.1 14.50 12.00 T*(8,L)X*B12 17.5 FC/MC/PC18B 580 18.0 14.6 14.00 12.00 T*(8,L)X*B12 17.5 FC/MC/PC24B 620 18.0 14.9 14.00 12.00 T*(8,L)X*B12 17.5 FC/MC/PC30B 620 18.0 14.9 14.00 12.00 T*(8,L)
Resumen del contenido incluido en la página 8
571209-YTG-C-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL Net MBH 1 RATED MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC32A 775 24.0 17.2 14.00 12.00 T*(8,L)V*A12 14.5 FC/MC/PC37A 805 24.0 17.3 14.50 12.00 T*(8,L)V*B12 17.5 FC/MC/PC35B 760 24.0 17.2 14.00 12.00 T*(8,L)V*B12 17.5 FC/MC/PC43B 760 24.0 17.2 14.00 12.00 T*(8,L)V*C16 21.0 FC/MC/PC35C 855 24.0 17.6 14.50 1
Resumen del contenido incluido en la página 9
571209-YTG-C-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL Net MBH 1 RATED MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC32A 1045 30.0 22.0 13.50 11.00 T*(8,L)V*A12 14.5 FC/MC/PC37A 950 30.0 22.0 14.50 12.00 T*(8,L)V*B12 17.5 FC/MC/PC35B 995 30.0 22.0 14.50 12.00 T*(8,L)V*B12 17.5 FC/MC/PC43B 1040 30.0 22.8 14.50 12.00 T*(8,L)V*C16 21.0 FC/MC/PC35C 1025 30.0 22.0 14.5
Resumen del contenido incluido en la página 10
571209-YTG-C-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL Net MBH 1 RATED MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*C20 21.0 FC/MC/PC48C 1155 36.0 26.6 14.50 12.00 T*(8,L)V*C20 21.0 UC48C 1155 36.0 26.8 14.50 12.00 T*(8,L)X*A12 14.5 FC/MC/PC37A 1290 36.0 27.6 14.50 12.00 T*(8,L)X*B12 17.5 FC/MC/PC43B 1300 36.0 27.6 14.50 12.00 T*(8,L)X*C16 21.0 FC/MC/PC43C 1175 36.0 26.8 14.50 12
Resumen del contenido incluido en la página 11
571209-YTG-C-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL Net MBH 1 RATED MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*C16 21.0 FC/PC60C 1420 41.5 32.2 14.00 12.00 T*(8,L)V*C16 21.0 UC60C 1420 41.0 31.4 13.75 11.50 T*(8,L)V*C20 21.0 FC/PC60C 1410 42.0 32.4 14.00 12.00 T*(8,L)V*C20 21.0 UC60C 1410 41.0 31.4 14.00 12.00 T*(8,L)X*C16 21.0 FC/PC60C 1360 42.0 32.6 14.50 12.00 T*(8,L)X*C1
Resumen del contenido incluido en la página 12
571209-YTG-C-1012 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL Net MBH 1 RATED MODEL MODEL MODEL WIDTH SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*9(C,V)*D20 24.5 FC/MC/PC60D 1615 44.5 33.6 14.00 12.00 T*9(C,V)*D20 24.5 FC/MC62D 1630 45.0 34.0 14.00 12.00 T*9(C,V)*D20 24.5 UC60D 1615 44.0 33.0 14.00 12.00 T*9X*C16 21.0 FC/MC62D 1550 45.0 34.2 14.50 12.00 T*9X*C16 21.0 FC/PC60C 1575 44.5 33.8 14.50 12.00 T*9X*C16 21.0
Resumen del contenido incluido en la página 13
571209-YTG-C-1012 HEATING CAPACITY - With Air Handler 2 HEATING 1 UNIT AIR COIL 47 F 17 F HSPF MODEL HANDLER MODEL MBH COP KW MBH COP KW STD 13 SEER HP WITH AIR HANDLERS AHE18B – 18.0 3.70 1.43 11.1 2.28 1.43 7.70 AHR18B – 18.0 3.54 1.49 11.4 2.22 1.50 7.70 AHV18B – 18.0 3.50 1.51 11.1 2.22 1.46 8.00 AV*24 – 18.0 3.66 1.36 9.9 2.78 1.06 8.20 MV12B FC/MC18B 18.0 3.58 1.39 8.6 2.52 1.24 7.95 YHJD18S41S2 MV12B FC/MC24B 18.0 3.62 1.36 10.6 2.88 1.03 8.10 MV12B FC/MC30B 18.0 3.62 1.36 10.6 2.88 1.
Resumen del contenido incluido en la página 14
571209-YTG-C-1012 HEATING CAPACITY - With Air Handler (Continued) 2 HEATING 1 UNIT AIR COIL 47 F 17 FHSPF MODEL HANDLER MODEL MBH COP KW MBH COP KW STD 13 SEER HP WITH AIR HANDLERS AHE48D – 39.03.903.0021.82.642.528.20 AHR48D – 40.0 3.66 3.20 22.4 2.48 2.65 7.70 AHV48D – 39.5 3.86 3.00 21.0 2.54 2.42 8.20 AV*48 – 39.5 3.96 2.92 22.2 2.68 2.43 8.20 YHJD42S41S4 AV*60 – 39.5 3.98 2.91 22.2 2.70 2.41 8.20 MV16C FC60C 40.0 3.86 3.04 21.4 2.50 2.51 8.20 MV20D FC/MC60D 39.5 3.94 2.94 22.2 2.66 2.45
Resumen del contenido incluido en la página 15
571209-YTG-C-1012 HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings) 2 HEATING 1 UNIT COIL 47 F 17 F HSPF MODEL MODEL MBH COP KW MBH COP KW STD 13 SEER HP COIL ONLY RATINGS FC/MC/PC18 18.0 3.36 1.50 12.7 2.16 1.24 8.20 FC/MC/PC24 18.0 3.36 1.45 10.4 2.60 1.17 8.20 YHJD18S41S2 FC/MC/PC30 18.0 3.42 1.54 11.4 2.18 1.53 7.75 UC24 18.0 3.42 1.54 11.4 2.20 1.52 7.75 UC30 18.0 3.42 1.54 11.4 2.20 1.52 7.75 FC/MC/PC32 24.0 3.36 2.09 13.9 2.38 1.71 7.70 FC/MC/PC3
Resumen del contenido incluido en la página 16
571209-YTG-C-1012 HEATING CAPACITY - With High Efficiency Motor Furnaces 2 HEATING 1 FURNACE COIL MODEL 47 F 17 FHSPF MODEL MODEL MBH COP KW MBH COP KW STD 3 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 FC/MC/PC18A 18.0 3.58 1.37 7.7 2.28 0.99 8.00 T*(8,L)V*A12 FC/MC/PC24A 18.0 3.70 1.36 10.6 2.90 1.07 8.30 T*(8,L)V*A12 FC/MC/PC30A 18.0 3.70 1.36 10.6 2.90 1.07 8.30 T*(8,L)V*A12 UC18A 18.0 3.62 1.37 9.1 2.58 1.03 8.10 T*(8,L)V*A12 UC24A 18.0 3.72 1.36 10.7 2.94 1.07 8.30 T*(8,L
Resumen del contenido incluido en la página 17
571209-YTG-C-1012 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) 2 HEATING 1 FURNACE COIL MODEL 47 F 17 F HSPF MODEL MODEL MBH COP KW MBH COP KW STD 3 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES Y*(8,L)C*B12 UC24B 18.0 3.70 1.34 10.5 2.96 1.04 8.20 Y*(8,L)C*B12 UC30B 18.0 3.70 1.34 10.4 2.96 1.03 8.20 Y*9C*B12 FC/MC/PC18B 18.0 3.60 1.36 7.7 2.30 0.98 8.00 Y*9C*B12 FC/MC/PC24B 18.0 3.74 1.34 10.5 2.94 1.05 8.30 YHJD18S41S2 Y*9C*B12 FC/MC/PC30B 18.0 3.74 1.34 10.5 2.94 1.
Resumen del contenido incluido en la página 18
571209-YTG-C-1012 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) 2 HEATING 1 FURNACE COIL MODEL 47 F 17 FHSPF MODEL MODEL MBH COP KW MBH COP KW STD 3 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 FC/MC/PC32A 27.43.302.4316.02.322.027.85 T*(8,L)V*A12 FC/MC/PC37A 27.2 3.48 2.29 15.7 2.42 1.90 8.05 T*(8,L)V*B12 FC/MC/PC35B 27.0 3.42 2.31 15.6 2.42 1.89 7.95 T*(8,L)V*B12 FC/MC/PC43B 27.6 3.52 2.30 15.7 2.42 1.90 8.15 T*(8,L)V*C16 FC/MC/PC35C 26.8 3.48 2.26 15.5 2
Resumen del contenido incluido en la página 19
571209-YTG-C-1012 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) 2 HEATING 1 FURNACE COIL MODEL 47 F 17 F HSPF MODEL MODEL MBH COP KW MBH COP KW STD 3 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)X*C20 FC/MC/PC43C 34.0 3.66 2.72 21.4 2.80 2.24 8.20 T*(8,L)X*C20 FC/MC/PC48C 34.2 3.70 2.71 21.6 2.84 2.23 8.20 T*(8,L)X*C20 UC48C 34.6 3.80 2.67 21.8 2.84 2.25 8.20 T*9(C,V)*B12 FC/MC/PC43B 34.2 3.48 2.88 22.0 2.66 2.42 8.20 T*9(C,V)*C16 FC/MC/PC43C 34.0 3.52 2.83 22.0
Resumen del contenido incluido en la página 20
571209-YTG-C-1012 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) 2 HEATING 1 FURNACE COIL MODEL 47 F 17 FHSPF MODEL MODEL MBH COP KW MBH COP KW STD 3 13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*9X*C20 FC/PC60C 40.03.982.9422.42.682.458.20 T*9X*C20 UC60C 39.5 3.90 2.97 22.2 2.64 2.46 8.20 T*9X*D20 FC/MC/PC60D 40.0 4.04 2.90 22.4 2.72 2.41 8.20 T*9X*D20 UC60D 39.5 4.00 2.89 22.4 2.70 2.43 8.20 Y*(8,L)C*C16 FC/PC60C 40.0 3.88 3.02 22.4 2.60 2.52 8.20 Y*(8,L)C*C16 UC60C 3