Résumé du contenu de la page N° 1 
                    
                          EXCELL PRECISION CO., LTD.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
User Manual 
 
 
© Excell Precision Limited 2006.  All rights reserved Worldwide. 
 
The information contained herein is the property of Excell Precision Limited and is supplied 
without liability for errors or omissions.  No part may be reproduced or used except as 
authorised by contract or other written permission.  The copyright and the foregoing 
restriction on reproduction and use extend to all media in which the inf
                    
                    Résumé du contenu de la page N° 2 
                    
                          EXCELL PRECISION CO., LTD.    TABLE OF CONTENT  SAFETY PRECAUTION.......................................................................3    FEATURES AND SPECIFICATION..........................4  1-1 FEATURES............................................................................................................................4  1-2 SPECIFICATION.....................................................................................................................5    KE
                    
                    Résumé du contenu de la page N° 3 
                    
                          EXCELL PRECISION CO., LTD.      TRANSMISSION INTERFACE ............................... 24  7-1  OP-01 RS232 / RS485 SERIAL OUTPUT (WITH RTC)........................................................ 24  2  Pin Allocation of Rear Panel........................................................................................................................24  2  Connection Description (RS485) .................................................................................................
                    
                    Résumé du contenu de la page N° 4 
                    
                          EXCELL PRECISION CO., LTD.         BEFORE USING THE INDICATOR  Thanks for purchasing EXCELL FM Mini-indicator. In  order to operate smoothly, to last the durability, and to  reduce the chance of breakdown for this product,  please read the following instructions carefully.        Safety Precaution  &  Turn off power before installing or disassembling.  & Keep the product away from sunshine. The temperature range for operation  is -10℃℃ ~ +40 .  & To connect the ground is a must for this equipm
                    
                    Résumé du contenu de la page N° 5 
                    
                          EXCELL PRECISION CO., LTD.      Features and Specification  1-1 Features  l Large and clear LCD (height 25.4mm × 10mm)  l LED Backlight, more duration, more energy saving  l Auto zero tracking  l Weighing calibration in both kilogram and pound  l High resolution switch function to display 10 times divisions  l Weighing unit shift function & data accumulation function   l Adjustable digital filter  l Available in connecting with up to four 350-ohm load cells  l Capable of connecting 
                    
                    Résumé du contenu de la page N° 6 
                    
                          EXCELL PRECISION CO., LTD.    1-2 Specification    Analog Specification        ♦  Load Cell Current: DC 5V ±5% 60mA (Up to Four 350Ω Load Cells)        ♦  Max. Load Cell Input Voltage: 16 mV        ♦  Input Sensitivity: 0.12μV/D or more        ♦  Conversion Rate: Approximately 100 times/sec. (max.)        ♦  Resolution: 19 bits      Digital Specification        ♦  Display: LCD, 6 digits, height 25.4x10mm, LED backlight        ♦  Display Frequency: 50 times/sec. (max.)        ♦  Display Range: 
                    
                    Résumé du contenu de la page N° 7 
                    
                          EXCELL PRECISION CO., LTD.      Keypad Operation Instruction    Function Operation Description    ENTER  Press and hold      ,    General Function Refer to   Function    F1  Setting Parameter Setting for details  and then press     Setting for decimal point, capacity,  Weighing Adjust calibration division, zero tracking, and unstable  Parameter Setting switch to ON detecting, etc. Refer to 5-1  Specification Setting for details.  Refer to 5-2 Internal Weight  Adjust calib
                    
                    Résumé du contenu de la page N° 8 
                    
                          EXCELL PRECISION CO., LTD.      Front & Rear Panels  3-1 Front Panel    R     +-          TARE MOTION M+ GROSS PT   ZERO TARE GROSS  F2 F1 ENTER ESC NET  +       Indication:                 :  Battery charged status                 :  Battery charging status       TARE     :  Tare status       MOTION  :  Unstable weighing indication        M+       :  Accumulation status indication       GROSS   :  Gross weight       PT        :  Pre-tare    Keypad:        1) Power ON / OFF. Press a
                    
                    Résumé du contenu de la page N° 9 
                    
                          EXCELL PRECISION CO., LTD.    3-2 Rear Panel               1            2  5  3   4            1. Battery Case    2. RS232/485 Input/Output    3. DC 9V Power Input    4. Calibration Switch    5. Load Cell Connect Socket       8  FM User Manual                                                                       SME300000119                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 10 
                    
                          EXCELL PRECISION CO., LTD.       Installation    4-1 Load Cell           5 4 3 2 1     9 8 7 6     Load cell cable   Load cell    EXC+   SEN+     SIG+ SIG-       EXC-     SEN-       Shield               4-wired (5-wired) Load Cell 6-wired (7-wired) Load Cell     Short Pin4&5 to connect with EXC+    Pin5 connects with EXC+     Short Pin2&3 to connect with EXC-    Pin4 connects with SEN+     Pin1 connects with SIG+    Pin3 connects with EXC-     Pin9 connects with SIG-    Pin2 connect
                    
                    Résumé du contenu de la page N° 11 
                    
                          EXCELL PRECISION CO., LTD.    4-2 Dimension                                                                                           10  FM User Manual                                                                       SME300000119                                                                                                                                                                                                                                                                       
                    
                    Résumé du contenu de la page N° 12 
                    
                          EXCELL PRECISION CO., LTD.    4-3 Battery Assembly                            將多餘的電線塞入電池孔中 Stuff the surplus wires into the battery case.                        11  FM User Manual                                                                       SME300000119                                                                                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 13 
                    
                          EXCELL PRECISION CO., LTD.      Internal Calibration    Adjust calibration switch to “ON”, and the screen displays:                                      After 2 seconds      ENTER                                                                              TARE                                  Press  ZERO              Press           ENTER                            TARE                              Press  ZERO                Press    ENTER                                 Adjust cal
                    
                    Résumé du contenu de la page N° 14 
                    
                          EXCELL PRECISION CO., LTD.     5-1 Specification Setting                           *Parameter Code              ENTER       Press         ⇒ Decimal Point                          ⇒ Capacity                             ⇒ Division 1  Input the *Parameter  Code intended                           ⇒ Division 2                                ⇒ Zero Tracking Setting         ENTER             Press         ⇒ Unstable Detecting Setting                          The screen displays the parameters set pre
                    
                    Résumé du contenu de la page N° 15 
                    
                          EXCELL PRECISION CO., LTD.    2  Specification Parameter Description  Setting Default  Parameter  Function  Setting  Code  Description  Parameter  Decimal  CSP-00  Refer to the description on next page.   Point  999999  CSP-01 Capacity ↓ Max. value for weight display 999999  000000  1  2  5  CSP-02 Division 1 Min. value for weight display 1  10  20  50  1  2  5  CSP-03 Division 2 Min. value for Weight display 1  10  20  50  Zero  CSP-04 Tracking  Refer to the description on next page.   Settin
                    
                    Résumé du contenu de la page N° 16 
                    
                          EXCELL PRECISION CO., LTD.    2  Parameter Display Description  CSP-00   Decimal Point  Display Decimal Point Digit  None         1 Digit       .  2 Digits       .   3 Digits       .     4 Digits       .     CSP-04   Zero Tracking Setting  Display Division/Period    0.25 D/1 sec  .         0.5 D/1 sec  .        0.75 D/1 sec  .      1D/1 sec         1.25 D/2 sec  .        1.5 D/2 sec  .        1.75 D/2 sec  .      2 D/2 sec       No Zero Tracking     CSP-05   Unstable Detecting Setting  Display
                    
                    Résumé du contenu de la page N° 17 
                    
                          EXCELL PRECISION CO., LTD.     5-2 Internal Weight Calibration            Turn on and warm up the machine for 15 to 30 minutes before calibration.  Adjust calibration switch to “ON”, and the screen will display   .      TARE ZERO  Press     or     to select        .       Procedure                   ENTER          ENTER       Zero  Zero calibration complete       Calibration         ESC       ENTER ENTER  Place the    Weight     weight mass       Calibration Confirmed  and set the    weight   
                    
                    Résumé du contenu de la page N° 18 
                    
                          EXCELL PRECISION CO., LTD.    2  Password Setting          Adjust calibration                  switch to “ON”                  After 2 seconds                    ZERO                         F1      Input new password          4  “0000” means no password.                   ENTER      Confirm new password                    (re-input again)       ENTER                       4  After complete password setting, when entering calibration mode or function         setting mode, the screen displays  
                    
                    Résumé du contenu de la page N° 19 
                    
                          EXCELL PRECISION CO., LTD.     5-3 Internal Function Setting                               ENTER       Press  *Parameter Code                     ⇒ Tare or Zero Function under           Unstable Status                 ⇒ Turning on Re-zero  Input the *Parameter    code intended              ⇒ Re-zero Range                               ⇒ Filter Strength      ENTER              Press           ⇒ AD Sampling Rate                           ⇒ Animal Scale Mode                    The screen displays
                    
                    Résumé du contenu de la page N° 20 
                    
                          EXCELL PRECISION CO., LTD.    2  Internal Function Parameter Description  Setting Default  Parameter  Function  Setting  Code  Parameter Description  Tare or Zero  0 ON  CFN-00 0  Function under  1 OFF  Unstable Status  0 OFF  Re-zeroing after  CFN-01 0  Turning on  1 ON  0%: Full range re-zero  CFN-02 Re-zero Range 0% ~ 30% 1% ~ 30%:  0  Capacity × ± setting value%  CFN-03 Filter Strength 0 ~ 5 Strength increases by number 2  0 No limit  1 20 times/sec.  AD Sampling  CFN-04 2  Rate  2 10 time