Excell Precision FM user manual

User manual for the device Excell Precision FM

Device: Excell Precision FM
Category: Scale
Manufacturer: Excell Precision
Size: 0.68 MB
Added : 2/28/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Excell Precision FM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Excell Precision FM.

For your convenience

If looking through the Excell Precision FM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Excell Precision FM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Excell Precision FM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Excell Precision FM User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Excell Precision FM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Excell Precision FM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EXCELL PRECISION CO., LTD.





















User Manual


© Excell Precision Limited 2006. All rights reserved Worldwide.

The information contained herein is the property of Excell Precision Limited and is supplied
without liability for errors or omissions. No part may be reproduced or used except as
authorised by contract or other written permission. The copyright and the foregoing
restriction on reproduction and use extend to all media in which the inf

Summary of the content on the page No. 2

EXCELL PRECISION CO., LTD. TABLE OF CONTENT SAFETY PRECAUTION.......................................................................3 FEATURES AND SPECIFICATION..........................4 1-1 FEATURES............................................................................................................................4 1-2 SPECIFICATION.....................................................................................................................5 KE

Summary of the content on the page No. 3

EXCELL PRECISION CO., LTD. TRANSMISSION INTERFACE ............................... 24 7-1 OP-01 RS232 / RS485 SERIAL OUTPUT (WITH RTC)........................................................ 24 2 Pin Allocation of Rear Panel........................................................................................................................24 2 Connection Description (RS485) .................................................................................................

Summary of the content on the page No. 4

EXCELL PRECISION CO., LTD. BEFORE USING THE INDICATOR Thanks for purchasing EXCELL FM Mini-indicator. In order to operate smoothly, to last the durability, and to reduce the chance of breakdown for this product, please read the following instructions carefully. Safety Precaution & Turn off power before installing or disassembling. & Keep the product away from sunshine. The temperature range for operation is -10℃℃ ~ +40 . & To connect the ground is a must for this equipm

Summary of the content on the page No. 5

EXCELL PRECISION CO., LTD. Features and Specification 1-1 Features l Large and clear LCD (height 25.4mm × 10mm) l LED Backlight, more duration, more energy saving l Auto zero tracking l Weighing calibration in both kilogram and pound l High resolution switch function to display 10 times divisions l Weighing unit shift function & data accumulation function l Adjustable digital filter l Available in connecting with up to four 350-ohm load cells l Capable of connecting

Summary of the content on the page No. 6

EXCELL PRECISION CO., LTD. 1-2 Specification Analog Specification ♦ Load Cell Current: DC 5V ±5% 60mA (Up to Four 350Ω Load Cells) ♦ Max. Load Cell Input Voltage: 16 mV ♦ Input Sensitivity: 0.12μV/D or more ♦ Conversion Rate: Approximately 100 times/sec. (max.) ♦ Resolution: 19 bits Digital Specification ♦ Display: LCD, 6 digits, height 25.4x10mm, LED backlight ♦ Display Frequency: 50 times/sec. (max.) ♦ Display Range:

Summary of the content on the page No. 7

EXCELL PRECISION CO., LTD. Keypad Operation Instruction Function Operation Description ENTER Press and hold , General Function Refer to Function F1 Setting Parameter Setting for details and then press Setting for decimal point, capacity, Weighing Adjust calibration division, zero tracking, and unstable Parameter Setting switch to ON detecting, etc. Refer to 5-1 Specification Setting for details. Refer to 5-2 Internal Weight Adjust calib

Summary of the content on the page No. 8

EXCELL PRECISION CO., LTD. Front & Rear Panels 3-1 Front Panel R +- TARE MOTION M+ GROSS PT ZERO TARE GROSS F2 F1 ENTER ESC NET + Indication: : Battery charged status : Battery charging status TARE : Tare status MOTION : Unstable weighing indication M+ : Accumulation status indication GROSS : Gross weight PT : Pre-tare Keypad: 1) Power ON / OFF. Press a

Summary of the content on the page No. 9

EXCELL PRECISION CO., LTD. 3-2 Rear Panel 1 2 5 3 4 1. Battery Case 2. RS232/485 Input/Output 3. DC 9V Power Input 4. Calibration Switch 5. Load Cell Connect Socket 8 FM User Manual SME300000119

Summary of the content on the page No. 10

EXCELL PRECISION CO., LTD. Installation 4-1 Load Cell 5 4 3 2 1 9 8 7 6 Load cell cable Load cell EXC+ SEN+ SIG+ SIG- EXC- SEN- Shield 4-wired (5-wired) Load Cell 6-wired (7-wired) Load Cell Short Pin4&5 to connect with EXC+ Pin5 connects with EXC+ Short Pin2&3 to connect with EXC- Pin4 connects with SEN+ Pin1 connects with SIG+ Pin3 connects with EXC- Pin9 connects with SIG- Pin2 connect

Summary of the content on the page No. 11

EXCELL PRECISION CO., LTD. 4-2 Dimension 10 FM User Manual SME300000119

Summary of the content on the page No. 12

EXCELL PRECISION CO., LTD. 4-3 Battery Assembly 將多餘的電線塞入電池孔中 Stuff the surplus wires into the battery case. 11 FM User Manual SME300000119

Summary of the content on the page No. 13

EXCELL PRECISION CO., LTD. Internal Calibration Adjust calibration switch to “ON”, and the screen displays: After 2 seconds ENTER TARE Press ZERO Press ENTER TARE Press ZERO Press ENTER Adjust cal

Summary of the content on the page No. 14

EXCELL PRECISION CO., LTD. 5-1 Specification Setting *Parameter Code ENTER Press ⇒ Decimal Point ⇒ Capacity ⇒ Division 1 Input the *Parameter Code intended ⇒ Division 2 ⇒ Zero Tracking Setting ENTER Press ⇒ Unstable Detecting Setting The screen displays the parameters set pre

Summary of the content on the page No. 15

EXCELL PRECISION CO., LTD. 2 Specification Parameter Description Setting Default Parameter Function Setting Code Description Parameter Decimal CSP-00 Refer to the description on next page. Point 999999 CSP-01 Capacity ↓ Max. value for weight display 999999 000000 1 2 5 CSP-02 Division 1 Min. value for weight display 1 10 20 50 1 2 5 CSP-03 Division 2 Min. value for Weight display 1 10 20 50 Zero CSP-04 Tracking Refer to the description on next page. Settin

Summary of the content on the page No. 16

EXCELL PRECISION CO., LTD. 2 Parameter Display Description CSP-00 Decimal Point Display Decimal Point Digit None 1 Digit . 2 Digits . 3 Digits . 4 Digits . CSP-04 Zero Tracking Setting Display Division/Period 0.25 D/1 sec . 0.5 D/1 sec . 0.75 D/1 sec . 1D/1 sec 1.25 D/2 sec . 1.5 D/2 sec . 1.75 D/2 sec . 2 D/2 sec No Zero Tracking CSP-05 Unstable Detecting Setting Display

Summary of the content on the page No. 17

EXCELL PRECISION CO., LTD. 5-2 Internal Weight Calibration Turn on and warm up the machine for 15 to 30 minutes before calibration. Adjust calibration switch to “ON”, and the screen will display . TARE ZERO Press or to select . Procedure ENTER ENTER Zero Zero calibration complete Calibration ESC ENTER ENTER Place the Weight weight mass Calibration Confirmed and set the weight

Summary of the content on the page No. 18

EXCELL PRECISION CO., LTD. 2 Password Setting Adjust calibration switch to “ON” After 2 seconds ZERO F1 Input new password 4 “0000” means no password. ENTER Confirm new password (re-input again) ENTER 4 After complete password setting, when entering calibration mode or function setting mode, the screen displays

Summary of the content on the page No. 19

EXCELL PRECISION CO., LTD. 5-3 Internal Function Setting ENTER Press *Parameter Code ⇒ Tare or Zero Function under Unstable Status ⇒ Turning on Re-zero Input the *Parameter code intended ⇒ Re-zero Range ⇒ Filter Strength ENTER Press ⇒ AD Sampling Rate ⇒ Animal Scale Mode The screen displays

Summary of the content on the page No. 20

EXCELL PRECISION CO., LTD. 2 Internal Function Parameter Description Setting Default Parameter Function Setting Code Parameter Description Tare or Zero 0 ON CFN-00 0 Function under 1 OFF Unstable Status 0 OFF Re-zeroing after CFN-01 0 Turning on 1 ON 0%: Full range re-zero CFN-02 Re-zero Range 0% ~ 30% 1% ~ 30%: 0 Capacity × ± setting value% CFN-03 Filter Strength 0 ~ 5 Strength increases by number 2 0 No limit 1 20 times/sec. AD Sampling CFN-04 2 Rate 2 10 time


Alternative user manuals
# User manual Category Download
1 Excell Precision Counting User manual Scale 1
2 Excell Precision DIGITAL HIGH PRECISION WEIGHING S User manual Scale 6
3 Excell Precision High Precesion Counting User manual Scale 0
4 Excell Precision www.excell.com.tw/excell_en/uploads/product/200712... User manual Scale 30
5 Excell Precision Weighing User manual Scale 4
6 Excell Precision WEIGHING S User manual Scale 8
7 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
8 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
9 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
10 A&D FG-150KAL User manual Scale 1
11 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
12 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
13 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
14 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
15 A&D FG-150KBM User manual Scale 0