RIC-155 10/100BaseT to STM-1/OC-3 Converter Version 1.12 Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to t
ページ4に含まれる内容の要旨
Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the RIC-155 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the
ページ5に含まれる内容の要旨
General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel. Warning Danger of electric shock! Avoid any contact with the marked sur
ページ6に含まれる内容の要旨
Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any oth
ページ7に含まれる内容の要旨
Connection of Data and Telecommunications Cables Data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual. Ports Safety Status V.11, V.28, V.35, V.36, RS-530, SELV Safety Extra Low Voltage: X.21, 10 BaseT, 100 BaseT, Ports which do not present a safety hazard. Usually Unbalanced E1, E2, E3
ページ8に含まれる内容の要旨
Caution To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Attention Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions. Do not attempt to tamper with any carrier-provided equipment or connection har
ページ9に含まれる内容の要旨
Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN 55022 (CISPR-22) Warning This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures. Cet apparei
ページ10に含まれる内容の要旨
Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: RIC-155 conforms to the following standard(s) or other normative document(s): EMC: EN 55022:1998 Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement. EN 50024: 1998 Information technology equipment – Immunity characteristics –
ページ11に含まれる内容の要旨
Quick Start Guide Installation of RIC-155 should be carried out only by an experienced technician. If you are familiar with RIC-155, use this guide to prepare the units for operation. 1. Installing RIC-155 Connecting the Interfaces 1. Connect the STM-1/OC-3c equipment to the fiber optic or BNC rear panel connectors. 2. Connect the 10/100BT LAN to the DATA rear panel connector. 3. Use a cross cable to connect the control terminal to the rear panel CONTROL connector. or Connect a Tel
ページ12に含まれる内容の要旨
Quick Start Guide RIC-155 Installation and Operation Manual 4. When the ALM LED (red) starts blinking, press several times. RIC-155 automatically adjusts itself to the current terminal baud rate and responds with a string of dots. 5. Type several dots. When the hardware initialization is completed, the SIG and ALM LEDs flash rapidly six times. 6. Press to display the user name and password entry form. 7. Enter your user name and password and proceed with the management s
ページ13に含まれる内容の要旨
Contents Chapter 1. Introduction 1.1 Overview..................................................................................................................... 1-1 Versions................................................................................................................................1-1 Application...........................................................................................................................1-1 Features.......................................
ページ14に含まれる内容の要旨
Table of Contents Enabling and Disabling Pop-up Alarms ..................................................................................4-8 4.3 Configuring the Physical Ports...................................................................................... 4-9 Configuring the Ethernet Interface.........................................................................................4-9 Configuring the STM-1/OC-3c Interface .................................................................
ページ15に含まれる内容の要旨
Chapter 1 Introduction 1.1 Overview RIC-155 is a converter that enables simple and efficient connection of Fast Ethernet traffic over STM-1/OC-3c lines. Equipped with a 10/100BaseT and fiber optic or coaxial STM-1 interface, RIC-155 serves as cost-effective alternative to ATM devices and routers. The RIC-155’s packet-over-SONET encapsulation protocol enables virtually total utilization of SDH/SONET payload traffic, since only a small header is required. RIC-155 supports VLAN bridging, fl
ページ16に含まれる内容の要旨
Chapter 1 Introduction RIC-155 Installation and Operation Manual Features 10/100BaseT Interface RIC-155 Fast Ethernet interface operation conforms to the IEEE 802.3u, 802.3x and 802.1p standards, including VLAN applications. The Fast Ethernet interface supports the following functions: • Four levels of QoS, according to ToS or 802.3p • High performance lookup engine with support for up to 1024 MAC address entries with automatic learning and aging • Autonegotiation • Backpressure • Ha
ページ17に含まれる内容の要旨
RIC-155 Installation and Operation Manual Chapter 1 Introduction Management Setup, control and monitoring of status and diagnostics information can be performed using one of the following methods: • ASCII terminal connected to the V.24/RS-232 DTE control port • Telnet host via dedicated Ethernet management port • PC running a Web browsing application (ConfiguRAD) • Network management station running RADview, RAD’s SNMP network management application. ConfiguRAD is user-friendly Web-bas
ページ18に含まれる内容の要旨
Chapter 1 Introduction RIC-155 Installation and Operation Manual 1.2 Physical Description RIC-155 is a non-modular standalone unit, intended for tabletop or 19” rack installation. Figure 1-2 illustrates a 3D view of the RIC-155 unit. Figure 1-2. RIC-155 3D View The front panel includes seven LEDs, which display the status of power, alarm, 10/100BaseT traffic and fiber optic signal. For details, refer to Chapter 3. The back panel includes a power connector (AC or DC), a 10/100BaseT po
ページ19に含まれる内容の要旨
RIC-155 Installation and Operation Manual Chapter 1 Introduction 1.3 Functional Description This section contains functional descriptions of the RIC-155 circuit blocks, shown in Figure 1-3. Main Card Parallel CPU Interface CPU MDIO/MDC Interface Management POS Level 2t SDH/SONET Ethernet Fiber Optic/ Forward MII Interface Link SDH/SONET Network CPLD Electrical Ethernet Framer Network Interface Interlace Power Supply Figure 1-3. RIC-155 Block Diagram • Ethernet network interface support
ページ20に含まれる内容の要旨
Chapter 1 Introduction RIC-155 Installation and Operation Manual • Fiber optic/electrical interface provides connection to the fiber optic or coaxial cables. • CPU controls the RIC-155 operation. It includes a microprocessor, flash memory, and SRAM. • Power supply provides 5V and +3.3V voltage to the RIC-155 internal elements. 1.4 Technical Specifications Number of Ports 1 10/100BaseT Interface Compatibility Relevant sections of IEEE 802.3u, 802.3x, 802.1p and 802.3q Data Rate 10