ページ1に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 1
Definition Install DC6i
Product Description Features
• 150mm (6.00”) high sensitivity, point source and
The Definition Install DC6i has been designed around the unique Tannoy Dual Concentric™
constant directivity Dual Concentric™ drive unit
drive unit to bring class leading performance to a wide range of installation applications;
from media rooms to home theatre and boardrooms through to high end marine interiors
• Constant time delay ov
ページ2に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 2 Definition Install DC6i TECHNICAL SPECIFICATIONS System Definition Install DC6i Construction (1) Enclosure MDF, vented and internally braced Frequency Range 70Hz - 45kHz (2) Finish Textured black paint System Sensitivity (1W @1m) 90dB (1W = 2.83V for 8 Ohms) Connectors 2 x 4mm gold plated binding posts Dispersion (-6dB) 90 degrees conical Fittings 8 x M10 bracket inserts, 4 wall plate Driver Complement 1 x 150mm (6.00”) point keyhole fixi
ページ3に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 3 Definition Install DC6i PERFORMANCE MEASUREMENTS 1m on-axis frequency response 100 90 80 70 60 50 10 100 1000 10000 100000 ANECHOIC frequency (Hz) FREQUENCY RESPONSE Impedance vs frequency 30 25 20 15 10 5 0 10 100 1000 10000 frequency (Hz) IMPEDANCE Horizontal off-axis response 100 90 80 0 deg 10 deg 70 20deg 30deg 40deg 60 50 10 100 1000 10000 100000 OFF AXIS frequency (Hz) RESPONSE Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enqu
ページ4に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:07 Page 4 Definition Install DC6i PERFORMANCE MEASUREMENTS Vertical off-axis response 100 90 80 0 deg 10 deg 70 20deg 30deg 40deg 60 50 OFF AXIS 10 100 1000 10000 100000 frequency (Hz) RESPONSE Beamwidth vs Frequency 360 330 300 270 240 210 180 150 120 90 60 30 0 100 1000 10000 frequency (Hz) BEAMWIDTH DI vs Frequency 100 10 Q 1 100 1000 10000 frequency (Hz) DIRECTIVITY INDEX Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Ta
ページ5に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 5 Definition Install DC6i PERFORMANCE MEASUREMENTS POLAR PLOTS (1/3 OCTAVE) 10 Hz 250Hz 125Hz 315Hz 0 0 160Hz 400Hz 20 Hz 500Hz 330 0 30 330 30 0 -12 -12 300 60 300 60 -24 -24 -36 -36 -48 -48 270 90 270 90 6 63 30 0H Hzz 1 1..6 6 k kH Hz z 8 80 00 0H Hzz 2 2.k 0H kH zz 0 0 1 1.0 kH kH zz 2 2..5 5 k kH Hz z 1 1..2 25 5kk H H zz 3 3..1 15 5 k kH Hz z 330 0 30 330 0 30 -12 -12 300 60 300 60 -24 -24 -36 -36 -48 -48 270 90 270 90 4.0kHz 1.0kHz 5
ページ6に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 6 Definition Install DC6i PERFORMANCE MEASUREMENTS POLAR PLOTS (1/3 OCTAVE) 10 Hz 250Hz 125Hz 315Hz 0 0 160Hz 400Hz 20 Hz 500Hz 330 0 30 330 30 0 -12 -12 300 60 300 60 -24 -24 -36 -36 -48 -48 270 90 270 90 6 63 30 0H Hz z 1 1..6 6 k kH Hz z 8 80 00 0H Hz z 2 2.k 0H kH zz 0 0 1 1.k 0H kH z z 2 2..5 5 k kH Hz z 1 1..2 25 5k kH Hz z 3 3..1 15 5 k kH Hz z 330 0 30 330 0 30 -12 -12 300 60 300 60 -24 -24 -36 -36 -48 -48 270 90 270 90 4.0kHz 1.0kH
ページ7に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 7 Definition Install DC6i DIMENSIONAL SKETCHES 250.0 214.6 250.0mm 214.6mm 9.84” 8.45” [9.84"] [8.45"] 334.0mm 334.0 13.15” [13.15"] SUPPLIED WALL MOUNTING PLATE 12 10 20.0 .0mm 150.0mm 150.0 150.0 [4.72"] 4.72” 5.91” [5.91"] [5.91"] 909 .0 0m .0m 11 55 00.0 .0mm [3.54"] [5.91"] 3.54” 5.91” Ø5 Ø5.0 .0mm [Ø0.20"] Ø0.20” Fixing hole dimensions Tannoy United Kingdom T: 00 44 (0) 1236 420199 E: enquiries@tannoy.com Tannoy North America T: 00 1
ページ8に含まれる内容の要旨
Defintion_DC6i_DJ_amends:Layout 1 16/01/2008 11:08 Page 8 Definition Install DC6i Architectural specifications The loudspeaker shall consist of a 150mm (6.00”) full range, point source Dual Concentric™ transducer. The low and high frequency elements shall be combined by an internal passive crossover network operating at 1.6kHz with dynamic HF protection. Performance of the loudspeaker, without any electronic control, shall meet or exceed the following criteria: Frequency range measured at 1 metr