KVM Extender User Station &  
Cat.5 KVM Extender 
 
 
User Manual     English 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LINDY No. 32357, 32358, 32359 
LINDY No. 39356, 39357 
 
 
 
   www.LINDY.com 
Tested to Comply with  
FCC Standards 
For Commercial Use Only! 
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH  -  SECOND EDITION (FEB 2008)                                                                                                                                          
                    
                    ページ2に含まれる内容の要旨 
                    
                        English Manual                 2    Introduction    Thank you for choosing the KVM Extender User Station Product series from LINDY.     Each of the models have been designed to take full advantage of CAT.x structured cabling  (where x means category 5, 5e or 6) to provide high quality linking plus ultimate flexibility for  installers and operators alike.  The User Stations can be either used in conjunction with LINDY MC5 KVM Switches or also as  a CAT.5 Extender Product in combination with the C
                    
                    ページ3に含まれる内容の要旨 
                    
                        English Manual                 3    Computer Access Modules (CAMs)  There are five different formats, depending on the required computer connections. It is possible  to combine USB user Stations with PS/2 CAMs and PS/2 User Stations with USB CAMs. If  CAMs are used in combination with the MC5/-IP KVM Switches a dedicated video  compensation should be used for each CAM that uses a CAT.5 cable longer than 10m. These  settings are stored in the KVM Switch – for details please refer to the KVM Switc
                    
                    ページ4に含まれる内容の要旨 
                    
                        English Manual                 4      Installation       To connect a remote user  1 Place a User Station extender unit adjacent to   the remote user location.   2 Attach the video monitor, keyboard, mouse,   power adapter (and speaker) connectors to the     sockets of the User Station module.  3 Lay a suitable length of category 5, 5e or 6 cabling   between the User Station module and the MC5  unit  or CAM. Please refer to the section Cable lengths   for remote user locations opposite.  4 Attac
                    
                    ページ5に含まれる内容の要旨 
                    
                        English Manual                 5  Operation  Selecting and using computers   To select a system using the keyboard:  Use the hotkey to switch between the two computer systems. In each case, you need to  simultaneously press the currently configured hotkeys (by default, CTRL and SHIFT) together  with the number of the required system 1 or 2.  To disconnect from both systems press the hotkeys followed by 0.    Locking and unlocking the system  In situations where the computer systems (and their lo
                    
                    ページ6に含まれる内容の要旨 
                    
                        English Manual                 6    Video compensation  A User Station may be connected to a CAM by a maximum of 300m (980 feet). The MC5 units  allow computer systems to be placed up to 50m (160 feet) away and remote users to be  extended by a maximum of 300m (980 feet) including the largest distance between any CAM  and the MC5. Such long cable lengths can affect video signals, especially when higher screen  resolutions are used. In order to eliminate any video signal degradation, all MC5 unit
                    
                    ページ7に含まれる内容の要旨 
                    
                        English Manual                 7    To display a suitable high contrast image  The best way to clearly view the effect of sharpness  and brightness adjustments is to display a high  contrast image, with vertical edges, on the screen.   • Open a word processor, type the capital letter  ‘H’, or ‘M’ and increase the point size to 72 or  higher. For best results, the background should  be white and the character should be black.   • A BLACK shadow on the right of the character  indicates UNDER compe
                    
                    ページ8に含まれる内容の要旨 
                    
                        English Manual                 8  5. When no shadows are visible and the displayed images have crisp edges, press   to exit configuration mode and permanently save all settings.   The new compensation settings will be stored, even when power is removed or if a complete  reset is initiated. These settings should not require further changes unless the cabling  arrangements are altered.     Remote user skew adjustment  The category 5, 5e and 6 cabling consists of four pairs of  wires per ca
                    
                    ページ9に含まれる内容の要旨 
                    
                        English Manual                 9  create breaks across the colours and give you more opportunities to view the horizontal  position of each colour relative to the others.   2. On the remote user keyboard (connected to a User Station C5  Pro or C5 USB 300), simultaneously, press the hotkeys (by  default,  and ) along with  to enter  configuration mode.  The three keyboard indicators (‘Num Lock’, ‘Caps Lock’ and  ‘Scroll Lock’) will now begin to flash in sequence.     3. As ap
                    
                    ページ10に含まれる内容の要旨 
                    
                        Radio Frequency Energy, Certifications    Shielded cables must be used with this equipment to maintain compliance with radio frequency energy    emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.    FCC Warning  This equipment has been tested and found to comply with the limits for a Class B Digital device, pursuant to part 15  of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a  residenti