LST0789-001A                                                                                                                                                                                                                                                                                                        
                    
                    Summary of the content on the page No. 2 
                    
                        Getting Started Safety Precautions Information for Users on Disposal of Old Equipment [European Union] This symbol indicates that the electrical and electronic equipment should not be  disposed as general household waste at its end-of-life. Instead, the product  should be handed over to the applicable collection point for the recycling of  electrical and electronic equipment for proper treatment, recovery and recycling  in accordance with your national legislation. By disposing of this product c
                    
                    Summary of the content on the page No. 3 
                    
                        ● This installation should be made by a  Due to design modifications, data given in this qualified service person and should conform  instruction book are subject to possible change to all local codes. without prior notice. ● This installation shall be in accordance with  the National Electrical Code, ANSI/NFPA 70. WARNING: ● The unit is to be powered by an AC 24 V  TO REDUCE THE RISK OF FIRE OR power supply. ELECTRIC SHOCK, DO NOT The AC 24 V power supply should conform to  the following:Class 
                    
                    Summary of the content on the page No. 4 
                    
                        Getting Started These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. IMPORTANT SAFEGUARDS 1. Read all of these instructions. 2. Save these instructions for later use. 3. All warnings on the product and in the operating instructions should be adhered to. 4. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or  aerosol cleaners. Use a damp cloth for cleaning. 5. Do not use attachments not recommended by the appliance 
                    
                    Summary of the content on the page No. 5 
                    
                        Setting Using Internet Explorer Contents When the IP address of VN-X35U  is known ........................................ 33 Getting Started When the IP address of VN-X35U  Safety Precautions ..................................... 2 is unknown .................................... 33 Contents ..................................................... 5 Setup ........................................................ 33 Main Features ............................................. 6 Internet Explorer Setup
                    
                    Summary of the content on the page No. 6 
                    
                        Getting Started Main Features Privacy Mask Feature You can configure the privacy mask setting to  hide specific area in shooting area. High Picture Quality The camera unit of this product employs a  Motion Detection 1,250,000-pixel CCD (1/3") which enables high  This feature enables output of an alarm upon  quality video surveillance. detection of motion in the video image within  preset area. Support for Dual Stream Pre-/Post-recorded image files may be sent via  Simultaneous distribution of JP
                    
                    Summary of the content on the page No. 7 
                    
                        How to use this manual Operating Environment  Symbols used  Recommended Computer  Caution : Describes precautions concerning Specifications the operation of this product. OS : Windows XP (Professional or  Note : Describes reference information,  Home Edition) (SP2) such as functions and usage  : Windows Vista Business(SP1) restrictions of this product. CPU : Pentium4  2GHz or higher A : Indicates the reference page  Memory capacity : 1 GB or more numbers and reference items. Free hard disk spa
                    
                    Summary of the content on the page No. 8 
                    
                        Getting Started Cautionary Notes Saving Energy  When this product is not in use for a long  period of time, turn off the power of the  Maintenance and location of use system to ensure safety and reduce power  consumption.  This product is intended for use indoors.  Make sure that you use a housing etc., when  using it outdoors. Maintenance  Do not place this product in the following   Be sure to turn off the power before  environments. performing maintenance. Otherwise, it may malfunction or
                    
                    Summary of the content on the page No. 9 
                    
                         If the power supply voltage is momentarily  Others cut off or reduced due to lightning, turning on  of the air conditioner’s power, etc., the image   The cable stopper of the alarm terminal may  may be disrupted or noise interference may  come off in some cases. When mounting the  occur. cables, make sure to do so carefully.  When using multicast, make use of a   If a high luminance object (such as a lamp) is  IGMPv2-compliant network switch. shot, a white smear may appear at the upper  and
                    
                    Summary of the content on the page No. 10 
                    
                        Getting Started Name and Function of Parts Front / Bottom / Side H A G F B E C D I A Back Focus Adjustment Ring F [MAC address]Indicator This ring is used for adjusting the back focus. The MAC address is a unique physical address  of the product. This address cannot be altered. To operate, loosen the H back focus fastening  screw by turning it in the anti-clockwise direction, G Camera Mounting Bracket and turn the screw in the clockwise direction to  This bracket is pre-mounted to the bottom  fa
                    
                    Summary of the content on the page No. 11 
                    
                        Side JK MONITOR OUT PAL OFF NTSC RESET STATUS IRIS M L J [MONITOR OUT] Monitor Output Selection  Memo:                                                    Switch Pressing and holding the button for five seconds  or longer enables the service confirmation  Use this switch to select the availability of output  mode. The L [STATUS] indicator lights up in  from the N [MONITOR OUT] terminal as well as  orange color in this mode. Do not press the  the signal system.(A Page 12) button for 5 seconds or l
                    
                    Summary of the content on the page No. 12 
                    
                        Getting Started Name and Function of Parts  (continued) Rear R S N O N [MONITOR OUT] Monitor Video Signal P [ALARM INPUT/OUTPUT] Alarm Input/ Output Terminal (RCA) Output Terminals This is an output terminal for composite video Use these terminals to connect to an external  signals (1 V (p-p), output impedance of 75 K). alarm device. Use this terminal to connect to devices such as a (A Page 20) video monitor. Q [AC24V] Power Input Terminal This terminal is used for adjusting the camera  angle du
                    
                    Summary of the content on the page No. 13 
                    
                        Features Surveillance via Dual Stream Simultaneous distribution of JPEG and MPEG4  images enables real-time surveillance using  Surveillance Using Built-in Viewer MPEG4 (30 fps) and recording of JPEG images  at the same time. You can also lengthen the  VN-X35U comes with Built-in JPEG/MPEG4  recording time by lowering the frame rate,  Viewer and Audio Monitor. resolution, and picture quality settings for JPEG  JPEG images and MPEG4 images of VN-X35U  images. can be monitored using Built-in Viewe
                    
                    Summary of the content on the page No. 14 
                    
                        Getting Started Alarm Device VN-X35U Features (continued) MAC  address Input audio to computer / output audio  from computer Connect the mini jack R3.5 stereo cable to the  [AUDIO IN/OUT] terminal. Connect an external  Network microphone to the R ch of the mini jack R3.5  stereo cable. You can now monitor audio sound  Computer Sending JPEG images  that has been picked up such as on a computer.  before and after alarm  Connect the built-in amplifier speakers to the Lch  input to FTP to output aud
                    
                    Summary of the content on the page No. 15 
                    
                        Setup Procedures Step 1 Connection/Installation (A Page 16) Connect the lens mount, power supply cord,  LAN cable and alarm cable. Next, mount the camera to the ceiling. Make  sure to attach the fall prevention wire firmly to  the camera. After the camera is mounted,  connect the video monitor to the [MONITOR  OUT] terminal at the rear of the unit, followed  by adjusting the camera angle. You can select the video signals of the  [MONITOR OUT] terminal using the  [MONITOR OUT] switch. (ANTSCBor A
                    
                    Summary of the content on the page No. 16 
                    
                        Connection / Installation 3. When using a DC iris lens, pay attention  Mounting the Lens to the pin position before connecting the  lens cable Note:                                                        ● Make use of a megapixel lens. 2. MONITOR OUT PAL OFF NTSC RESET 1. Check the mounting method of the lens to  STATUS be used before mounting ● The mount method used for VN-X35U is CS IRIS mount. ● Make use of the values listed in the table  3. 1 3 below for the dimensions of the lens mount  (a)
                    
                    Summary of the content on the page No. 17 
                    
                        Power Connection MONITOR OUT PAL OFF NTSC RESET Electricity can be supplied to this product either  STATUS by connecting to the AC 24 V power supply or  using the PoE (A Page 18).  When power is supplied to this product, the  IRIS [STATUS] indicator at the side lights up. The  indicator lights up in orange color during  startup, and switches to green color after  startup is complete. [STATUS] Indicator Memo:                                                      Power cord  You can select not t
                    
                    Summary of the content on the page No. 18 
                    
                        Connection / Installation Power Connection (continued) LAN Cable Connection ● In a system where multiple units of VN-X35U Connect the camera to a hub or computer using  are used, turn on the power of only one unit  a LAN cable. to configure the IP address settings using the  Internet Explorer. Upon doing so, turn on the  Cable to use power of the second unit and configure  ● Shielded cable accordingly. Configure the camera settings  ● Length of 100 m or shorter using the same procedure. ● When t
                    
                    Summary of the content on the page No. 19 
                    
                        Monitor Signal Output Terminal Audio Signal Input/Output  Connection Terminal Connection Make use of this terminal for camera angle  Connect the mini jack R3.5 stereo cable. adjustment during installation or focus  L ch : Connect to speakers with built-in  adjustment in the Focus Assist mode. Connect it  amplifier, etc. to devices such as a video monitor using a video  cable (RCA). R ch : Connect to plug-in power type capacitor  microphone Memo:                                                   
                    
                    Summary of the content on the page No. 20 
                    
                        Connection / Installation Sensor Example  VN-X35U Alarm Input/Output Terminal  (1) DC3.3 V INPUT 1 or  VCC Connection 2 Terminal R R OUT Connect the alarm input/output terminals with  external devices, such as a sensor or buzzer. 3.3 V 1 mA Plug/Unplug the cable while pressing the button  G Terminal GND as shown in the diagram below. (Alarm Input Equivalent Circuit) Sensor Example  Cable to use (2) ● Shielded cable Relay Switch, etc. ● Length of 50 m or shorter OUT GND 1 2 G 21 21 AC24V ALARM Al