Our goal is to provide you with a quick access to the content of the user manual for Faria Instruments GM/ALDL. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Faria Instruments GM/ALDL.

For your convenience

If looking through the Faria Instruments GM/ALDL user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Faria Instruments GM/ALDL on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Faria Instruments GM/ALDL to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Faria Instruments GM/ALDL User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Faria Instruments GM/ALDL but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Faria Instruments GM/ALDL. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual

GM ALDL MG2000
Tachometer
IS0195
rev. A ecr#5576 8/2005

Summary of the content on the page No. 2

IS0195 x7 w/ corrections Mark ups 12/20/05

Summary of the content on the page No. 3

Index Figure 1 Default screens page 1 Description page 1 Normal Mode page 2 Contrast and Lighting page 2 Displayed Functions page 3 Default screen 1 page 3 Default screen 2 page 3 Default screen 3 page 3 Default screen 4 page 4 Figure 2 Screen Sequence page 4 Figure 3 LCD Display Screens page 5 Edit Mode page 7 Functions that are adjusted in Edit Mode. page 7 Select Default Screen page 7 Reset Fuel Used page 8 Set Fuel Tank Full page 8 Set Amount of Fuel page 9 Organize User Sc

Summary of the content on the page No. 4

This page left blank intentionally.

Summary of the content on the page No. 5

The FARIA MG2000 Tachometer combines the features of an ECU serial bus gateway and several instruments into one unit: • The tachometer is analog in appearance but driven by a stepper motor for digital accuracy. • The high resolution LCD screen displays information for many other functions and the various “screens” can be configured as the user wishes. As received, the screens are configured as shown in Fig. 1. The MG2000 receives digital engine data from the Engine Control Unit (ECU) v

Summary of the content on the page No. 6

(see Figure 2). Press the “Mode” button Normal Mode to exit the “screen selection mode” and When the MG2000 is turned on the unit return to “Normal” mode or do not push will “beep” once, flash once and then the any buttons for 4 seconds and the current unit enters “Self Test” mode. The screen screen will stay selected and the unit will will display “The Self Test Mode Is In return to “Normal” mode (see Figure 3). Operation” for 10 seconds. In the “Normal” operation mode, press the

Summary of the content on the page No. 7

OIL PRESSURE Analog input. Displays information from the analog oil pressure sender. Default Screen “2” To adjust the lighting intensity of all of the instruments in the system, press and hold both the “Down” and “Up” buttons for 2 seconds. The lighting intensity may now be adjusted by using the “Down” or “Up” buttons. Fuel Left Displays the quantity of fuel remaining in the fuel tank based on the original quantity of fuel in the tank when full and Return to the “Normal” mode by press

Summary of the content on the page No. 8

Displays the Engine Hours data received from the engine ECU. Default screen “4” LCD Display Screens: In “Normal” mode, press “Mode” once to This screen displays fault conditions enter screen “Select” mode, press “Up” based on engine data received from the or “Down” to move between screens. ECU or alarms based on internally set Press “Mode” once to return to “Normal” alarm points. Engine alarms from the mode. ECU will be displayed as “Check Engine !” Screen “1” or “Engine Emergency S

Summary of the content on the page No. 9

40 1. Select Default Screen 2. Reset Fuel Used 3. Set Fuel Tank Full 4. Set Amount of Fuel 5. Organize User Screens 6. Select Gauge Range 7. Select Fuel Sender 8. Select Oil Pressure Sender 9. Select Display Units 10. Select Fuel Tank Size 11. Fuel Tank Calibrate 12. Low Fuel Alarm 13. Software ID and Revision 14. Select Self Test Figure 3 Page 5

Summary of the content on the page No. 10

This page left blank intentionally. Page 6

Summary of the content on the page No. 11

Functions that are set or adjusted in the Edit Mode “Edit” mode: The “Edit” mode is used to adjust or set the values of numerous functions and 1. Select Default Screen options in the MG2000. The procedure 2. Reset Fuel Used below specifies the steps to be taken 3. Set Fuel Tank Full in the “Edit” mode to adjust / set each option. 4. Set Amount of Fuel To enter “Edit” mode, press the “Mode” 5. Organize User Screens and “Up” buttons while in “Normal” mode 6. Select Gauge Range 7. Select Fuel

Summary of the content on the page No. 12

Display 1 2 Next 3 Screen Press and hold the “Up” and “Down” buttons for 2 seconds to select this screen as the “default screen” and exit. Press “Up” or “Down” to select another screen. Repeat until desired “Default Screen” is selected. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. 1 Reset Reset “Fuel Used” 2 Fuel 3 Used Press and hold the “Up” and “Down” buttons for 2 seconds to reset “Fuel Used” to zero (0). Press “Up” or “Down” to select another fun

Summary of the content on the page No. 13

Set 1 Set “Amount of Fuel” 2 Amount 3 Of Fuel NOTE: If a known amount of fuel is in the fuel tank but it is not full, this function can be used to indicate the amount of fuel available. The “Fuel Left” function will then use the amount of fuel entered to calculate the “Fuel Left.” Press and hold the “Up” and “Down” buttons for 2 seconds to select “Current Amount of Fuel.” Press “Up” or “Down” to set the amount of fuel known 1 Fuel to be in the fuel tank. Adjust until the displayed volume

Summary of the content on the page No. 14

Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 1 and advance to Screen 1, line 2. Press “Mode” to exit with no change made. Screen 1 1 Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the 2 Line 2 number of the function to be displayed in screen 1, line 2. 3 Item XX Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 2 and advance to Screen 1, line

Summary of the content on the page No. 15

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Oil Pressure Dial.” Press “Up” or “Down” to select another “Gauge Range.” Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections. 1 > 60 psi When the correct choice is next to the selection arrow, 2 80 psi Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge 100 psi 3 Range” selection 1 Select Select “Coolant Temperature Dial” 2 Coo

Summary of the content on the page No. 16

Select 1 Select “Water Press Dial” 2 Water Press 3 Dial Press and hold the “Up” and “Down” buttons for 2 seconds to select “Water Press Dial.” Press “Up” or “Down” to select another “Gauge Range.” Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections. 1 > 30 PSI When the correct choice is next to the selection arrow, 2 45 PSI Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge 60 PSI 3 Range” selec

Summary of the content on the page No. 17

> USA 1 Press “Up” or “Down” to scroll through the selections. 240 – 33 ohm 2 When the correct choice is next to the selection arrow, EU 3 Press and hold the “Up” and “Down” buttons for 2 4 10 – 180 ohm seconds to save the selection and return to the “Edit” 5 Centroid mode. 6 Press “Up” or “Down” to select another function or “Mode” to return to the “Normal” mode. Select 1 Select “Oil Pressure Sender” 2 Oil Pressure 3 Sender Press and hold the “Up” and “Down” buttons for 2 seconds t

Summary of the content on the page No. 18

Press “Up” or “Down” to scroll through the selections. 1 > PSI When the correct choice is next to the selection arrow, 2 BAR Press and hold the “Up” and “Down” buttons for 2 3 seconds to save the selection and return to select “Units.” Select 1 Select “Volume Units” Volume 2 3 Units Press and hold the “Up” and “Down” buttons for 2 seconds to select “volume units” Press “Up” or “Down” to select another choice of “Units” Press “Up” or “Down” to scroll through the selections. 1 > GA

Summary of the content on the page No. 19

Press “Up” or “Down” to scroll through the selections. 1 > Miles When the correct choice is next to the selection arrow, 2 kM Press and hold the “Up” and “Down” buttons for 2 3 NM seconds to save the selection and return to select “Units.” Select 1 Select “Depth Units” 2 Depth 3 Units Press and hold the “Up” and “Down” buttons for 2 seconds to select “Depth Units” Press “Up” or “Down” to select another choice of “Units.” Press “Up” or “Down” to scroll through the selections. 1 >

Summary of the content on the page No. 20

Select 1 Other 2 If there is no tank size available in the list that matches your tank size, scroll to the next screen. 3 Fuel Tank 4 Size Press “Up” or “Down” to set the fuel tank size displayed 1 Select on the screen to match your fuel tank size. Line 4 value 2 Other will adjust. Fuel Tank 3 When set, Press and hold the “Up” and “Down” buttons XXX G 4 for 2 seconds to save and exit. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. Calibrate 1 Fuel Sele


Alternative user manuals
# User manual Category Download
1 Faria Instruments J1939 User manual Automobile Parts 1
2 Faria Instruments NMEA2000 User manual Automobile Parts 2
3 Faria Instruments PILOT IS0152 User manual Automobile Parts 4
4 Faria Instruments Performance IS0218 User manual Automobile Parts 0
5 Faria Instruments IS0135A User manual Automobile Parts 1
6 Faria Instruments MG2000 Speedometer MG2000TM User manual Automobile Parts 0
7 Faria Instruments IS0157 User manual Automobile Parts 0
8 Faria Instruments SMARTCRAFT MG2000 User manual Automobile Parts 10
9 Faria Instruments Speedometer/Depth Sounder User manual Automobile Parts 51
10 Faria Instruments Suzuki User manual Automobile Parts 1
11 Faria Instruments Commander User manual Automobile Parts 1
12 Sony BP-GL95 User manual Automobile Parts 25
13 Sony BP-GL65 User manual Automobile Parts 2
14 Philips Epic 50PF9966 User manual Automobile Parts 3
15 Philips HTS3011 User manual Automobile Parts 2
16 Philips SDJ6040W User manual Automobile Parts 1